Calculation of residence time distributions of intravascular radioactive tracers in fields of external registration

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Because of the physiological significance of the mean velocity of blood flow, indicator dispersion models are of special interest and posses practical relevance, if biological and extraneous variables can be altered. The variables being considered are flow characteristics of the streaming blood, tracer distribution at the entrance into the flow system, and the area in which impulses are collected to form the time-activity curve. Using a simplified version of the general convective diffusion equation (diffusion model) in which the diffusion constant D includes all propagation and mixing of the tracer, a simple numerical method can be applied. The method is used to determine influences of injection and changed regions of interest on the time-activity curve and the following parameters: appearance times, peak times, mean circulation times, and the times of the first inflection points. For this purpose, the range of D was determined in 14 patients by applying experimental data to the model. The calculations on the variables show, that the advantage of this method is its applicability to any experimental case by simply adapting the input data to the recordings.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

A:

cross-sectional area of the flow tube

c, c0 :

concentration

Bo:

v·Z/D (Bodenstein-number)

D :

mixing coefficient of the diffusion model

f(ϱ):

dimensionless initial indicator concentration

F :

flow

L :

width of the detector field on the x-axis

t :

time

T :

Z/v

U, u :

c/c 0 (solution of the partial differential equation; of the difference equation)

v :

mean flow velocity

V :

volume of the flow system

x :

space coordinate in flow direction

Z :

length of the flow system

ζ:

x/Z

ϱ:

t/T

References

  • Adam, W.E., Meyer, G., Bitter, F., Kampmann, H., Stauch, M.: Camera radiocardiography based on the first transit principle. J. Nucl. Biol. Med. 18, 44–52 (1974)

    Google Scholar 

  • Breuel, H.-P., de Vivie, R., Schmidt, B., Heimburg, P., Emrich, D.: Die klinische Bedeutung der Bestimmung von intrakardialen Kreislaufzeiten mit einem Radiopharmakon und einer EKG-gesteuerten Gamma-Kamera bei angeborenen und erworbenen Herzfehlern. Z. Kardiol. 63, 718–732 (1974)

    Google Scholar 

  • Cohn, P.F., Gorlin, R., Cohn, L.H., Collins, J.J.: Left ventricular ejection fraction as a prognostic guide in surgical treatment of coronary and valvular heart disease. Am. J. Cardiol. 34, 136–141 (1974)

    Google Scholar 

  • Donato, L., Giuntini, C., Lewis, M.L., Durand, J., Rochester, D.F., Harvey, R.M., Cournand, A.: Quantitative radiocardiography (I), (II), (III). Circulation 26, 174–199 (1962)

    Google Scholar 

  • Donato, J.: Basic concepts of radiocardiography. Seminars in Nucl. Med. 3, 111–130 (1973)

    Google Scholar 

  • Dow, P.: Estimates of cardiac output and central blood volume by dye dilution. Physiol. Rev. 36 (suppl. 2), 77–102 (1956)

    Google Scholar 

  • Feinendegen, L.E., Becker, V., Vyska, K., Schicha, H., Seipel, L.: Minimal cardiac transit times — diagnostic radiocardiography in heart disease. J. Nucl. Biol. Med. 16, 211–223 (1972)

    Google Scholar 

  • Gill, W.N., Sankarasubramanian, R.: Dispersion of a non-uniform slug in time-dependent flow. Proc. Roy. Soc. Lond. A 322, 101–117 (1971)

    Google Scholar 

  • González-Fernández, J.M.: Theory of the measurement of the dispersion of an indicator in indicator-dilution studies. Circ. Res. 10, 409–428 (1962)

    Google Scholar 

  • Hamilton, W.F.: Role of Starling concept in regulation of the normal circulation. Rev. 35, 160–168 (1955)

    Google Scholar 

  • Hofmann, H.: Der derzeitige Stand bei der Vorausberechnung der Verweilzeitverteilung in technischen Reaktoren. Chem. Engng. Sci. 24, 193–210 (1961)

    Google Scholar 

  • Knapp, W.H., Doll, J.: Eine automatisierte Methode zur Bestimmung von Kreislaufzeiten in der nuklearmedizinischen Herzdiagnostik. Nucl. Med. 16, 218–223 (1977)

    Google Scholar 

  • Lane, D.A., Patel, I.C., Sirs, J.A.: The variation of indicator dilution curves with velocity profile. Phys. Med. Biol. 20, 613–623 (1975)

    Google Scholar 

  • Maseri, A.: The practice of dilution methods for the estimate of cardiac output, pulmonary and ventricular blood volumes with radioisotopes. J. Nucl. Biol. Med. 16, 188–202 (1972)

    Google Scholar 

  • Mitchell, A.R.: Computational methods in partial differential equations. Chichester: John Wiley and Sons 1969

    Google Scholar 

  • Rossi, H.H., Powers, S.H., Dwork, B.: Measurement of flow in straight tubes by means of the dilution technique. Am. J. Physiol. 173, 103–108 (1953)

    Google Scholar 

  • Sarnoff, S.J., Mitchell, J.H.: The control of the function of the heart. In: Handbook of Physiology, W.F. Hamilton (ed.). Section 2: circulation I, pp. 489–532. Washington D.C.: American Physiological Society 1962

    Google Scholar 

  • Sheppard, C.W.: Mathematical considerations of indicator dilution techniques. Minn. Med. 15, 93–104 (1954)

    Google Scholar 

  • Stewart, G.N.: Research on the circulation time and on the influence which affect it. (III). J. Physiol. 15, 1 (1894)

    Google Scholar 

  • Strand, S.-E., Larsson, J.: Image artefacts at high photon fluence rates in single-crystal NaI(Tl) scintillation cameras. J. Nucl. Med. 19, 407–413 (1978)

    Google Scholar 

  • Ulrich, M.: Berechnung der Verweilzeitverteilung nach dem Durchmischungsmodell für Reaktionen beliebiger Ordnung. Chem.-Ing.-Techn. 43, 1248–1252 (1971)

    Google Scholar 

  • Vyska, K., Schicha, H., Becker, V., Seipel, L., Feinendegen, L.E.: Minimale kardiale Transitzeiten (MTTs) in der Herzdiagnostik-Messungen mit der Gamma-Retina V und Indium-113m. III. MTTs bei Myokardschädigung und nach Digitalisierung. Z. Kreislaufforschg. 61, 820–827 (1972)

    Google Scholar 

  • Vyska, K., Profant, N., Freundlieb, Chr., Schicha, H., Höck, A., Becker, V., Feinendegen, L.E.: Die theoretische Analyse minimaler kardiater Transitzeiten und die Messung der ventrikulären Ejektionsfraktion. In: Quality factors in nuclear medicine H. Munkner (ed.). Proc. 13. Int. Ann. Meeting Soc. Nucl. Med. in Kopenhagen, pp. 91.1–91.7. Kobenhavn: Fadl. s Forlag 1975

    Google Scholar 

  • Zierler, K.L.: Circulation times and the theory of indicator-dilution methods for determining blood flow and volume. In: Handbook of Physiology, W.F. Hamilton (ed.). Section 2: circulation I, pp. 585–615. Washington D.C.: American Physiological Society 1962

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Knapp, W.H., Lüdecke, H.J. & Doll, J. Calculation of residence time distributions of intravascular radioactive tracers in fields of external registration. Eur J Nucl Med 4, 471–477 (1979). https://doi.org/10.1007/BF00300849

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00300849

Keywords

Navigation