Skip to main content
Log in

A recycling technique for the chromatographic separation of enantiomers and diastereomers on triacetylcellulose

„Recycling-Chromatographie“ zur kontinuierlichen chromatographischen Trennung von Enantiomeren und Diastereomeren an Triacetylcellulose

  • Organische Chemie Und Biochemie
  • Published:
Monatshefte für Chemie / Chemical Monthly Aims and scope Submit manuscript

Abstract

A simple and inexpensive equipment for the optical resolution of enantiomers (and separation of diastereomers) on triacetylcellulose in ethanol at elevated pressure is described. It involves a closed circuit of solvent (pump—column—detector—pump) allowing a continuous chromatography up to 16 cycles without stopping the flow or handling fractions.

This useful and versatile method permitting also the determination of enantiomeric purities is illustrated by several examples of centro-, axial- and planarchiral arenes and metallocenes.

Zusammenfassung

Es wird eine einfache und preisgünstige Anlage zur Racematspaltung und Trennung von Diastereomeren an Triacetylcellulose in Ethanol unter erhöhtem Druck beschrieben. Sie beinhaltet einen geschlossenen Lösungsmittelkreislauf (Pumpe — Säule — Detektor — Pumpe) und ermöglicht eine kontinuierliche Arbeitsweise bis zu etwa 16 Zyklen, ohne den Fluß unterbrechen oder die Fraktionen handhaben zu müssen.

Diese offensichtlich universelle Methode, welche auch die Ermittlung enantiomerer Reinheiten erlaubt, wird an Hand von einigen zentro-, axial- und planarchiralen Arenen und Metallocenen vorgestellt.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Schlögl K., Widhalm M., Chem. Ber.115, 3042 (1982) and references cited therein;

    Google Scholar 

  2. Schlögl K., Weissensteiner W., Widhalm M., J. Org. Chem.47, 5052 (1982)

    Google Scholar 

  3. Schlógl K., Werner A., Widhalm M., J. Chem. Soc. Perkin TransactionsI 1983, 1731

    Google Scholar 

  4. Schlögl K., Widhalm M., Vogel E., Schwamborn M., Monatsh. Chem.114, 605 (1983).

    Google Scholar 

  5. Blaschke G., Kraft H. P., Markgraf H., Chem. Ber.116, 3611 (1983).

    Google Scholar 

  6. FMI-Metering Pump (Fluid Metering Inc., Oyster Bay, NY 11771, U.S.A.).

  7. Cf.Hagel G.,Hesse R., Liebigs Ann. Chem.1976, 996.

  8. Neudeck H.,Schlögl K.,Tscheplak H., unpublished results.

  9. Cf.Brown H. C., Jadhav P. K., Mandal A. K., J. Org. Chem.47, 5074 (1982).

    Google Scholar 

  10. Falk H., Schlögl K., Monatsh. Chem.96, 266 (1965).

    Google Scholar 

  11. Schlögl K.,Schöm R., Liebigs Ann. Chem.1980, 1877.

  12. Eyer M.,Schlögl K.,Widhalm M., Monatsh. Chem., in press.

  13. Caglioti L., Naef H., Arigoni D., Jeger O., Helv. Chim. Acta41, 2278 (1958).

    Google Scholar 

  14. Pinar M., Rodriguez B., Phytochemistry16, 1987 (1977).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Herrn Prof. Dr.U. Schmidt, Stuttgart, zum 60. Geburtstag gewidmet.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schlögl, K., Widhalm, M. A recycling technique for the chromatographic separation of enantiomers and diastereomers on triacetylcellulose. Monatsh Chem 115, 1113–1120 (1984). https://doi.org/10.1007/BF00798778

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00798778

Keywords

Navigation