Abstract

General description of an on-line procedure of calibration for IGRT (image guided radiotherapy) is given. The algorithm allows to improve targeting cancer by estimating its position in space and suggesting appropriate correction of the position of the patient. The description is given in the Geometric Algebra language which significantly simplifies calculations and clarifies presentation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Aragon-Camarasa, G., Aragon-Gonzalez, G., Aragon, J.L., Rodriguez-Andrade, M.A.: Clifford Algebra with Mathematica in Recent Advances on Applied Mathematics. In: Proceedings of the 20th International Conference on Applied Mathematics (AMATH’15), ISBN: 978-1-61804-354-2; arXiv:0810.2412 [math-ph]

  2. Chappell, J. M., Iqbal, A., Hartnett, J. G., Abbott, D.: The vector algebra war: a historical perspective. IEEE Access. 99, 1 (2016); https://doi.org/10.1109/ACCESS.2016.2538262; arXiv:1509.00501 [physics.hist-ph]

  3. Doran, C., Lasenby, A.: Geometric Algebra for Physicists. Cambridge University Press, Cambridge (2007)

    MATH  Google Scholar 

  4. Hestenes, D.: The Design of Linear Algebra and Geometry. Acta Applicandae Mathematicae. Kluwer Academic Publishers 23, 65–93 (1991)

    MathSciNet  Google Scholar 

  5. Hestenes, D., Ziegler, R.: Projective geometry with Clifford algebra. Acta Appl. Math. 23, 25–63 (1991)

    Article  MathSciNet  MATH  Google Scholar 

  6. Kycia, R.A., et al.: A framework for assumption-free assessment of imperfect geometry of linac C-arms, submitted; arXiv:1711.11002 [physics.med-ph]

  7. Li, X.A., Wu, Q., Orton, C.G.: Online adaptive planning for prostate cancer radiotherapy is necessary and ready now. Med. Phys. 41, 080601 (2014)

    Article  Google Scholar 

  8. Tabor, Z., et al.: A generic multi-module phantom for testing geometry of a linac c-arm as a part of quality control in radiotherapy. Med Phys. 44(10), 4989–5000 (2017). https://doi.org/10.1002/mp.12451

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. A. Kycia.

Additional information

Communicated by Rafał Abłamowicz

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kycia, R.A., Tabor, Z., Woszczyna, A. et al. A Framework for On-line Calibration of LINAC Devices. Adv. Appl. Clifford Algebras 28, 32 (2018). https://doi.org/10.1007/s00006-018-0849-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s00006-018-0849-8

Keywords

Navigation