Skip to main content
Log in

An Active Sampler for Monitoring Polychlorinated Dibenzo-p-dioxins and Furans in Ambient Air

  • Published:
Bulletin of Environmental Contamination and Toxicology Aims and scope Submit manuscript

Abstract

An active sampler for monitoring polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) in air was developed using an automobile air filter set. The performance of the mobile air sampler was evaluated. Recoveries of PCDD/F congeners ranged from 62.3% to 64.5% with sampling volumes of 500–1,800 m3. Air samples were collected between April and June, 2007 in Beijing. The monitoring results of PCDD/F levels by the mobile sampler were comparable to results obtained by a conventional stationary high-volume active sampler. The results suggest this mobile air sampling technology is a promising new strategy for the assessment of air quality in urban areas.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  • Chang H, Wang S, Wang Y, Li H, Wang L (2010) Contributions of dry and wet depositions of polychlorinated dibenzo-p-dioxins and dibenzofurans to a contaminated site resulting from a penetachlorophenol manufacturing process. Environ Monit Assess (in press). doi:10.1007/s10661-010-1545-x

  • Chao MR, Hu CW, Chen YL, Chang-Chien GP, Lee WJ, Chang LW, Lee WS, Wu KY (2004) Approaching gas-particle partitioning equilibrium of atmospheric PCDD/Fs with increasing distance from an incinerator: measurements and observations on modeling. Atmos Environ 38:1501–1510

    Article  CAS  Google Scholar 

  • Clarkson PJ, Larrazabal-Moya D, Staton I, McLeod CW, Ward DB, Sharifi VN, Swithenbank J (2002) The use of tree bark as a passive sampler for polychlorinated dibenzo-p-dioxins and furans. Int J Environ Anal Chem 82:843–850

    Article  CAS  Google Scholar 

  • Klanova J, Kohoutek J, Hamplova L, Urbanova P, Holoubek I (2006) Passive air sampler as a tool for long-term air pollution monitoring: Part 1. Performance assessment for seasonal and spatial variations. Environ Pollut 144:393–405

    Article  CAS  Google Scholar 

  • Li YM, Jiang GB, Wang YW, Cai ZW, Zhang QH (2008) Concentrations, profiles and gas-particle partitioning of polychlorinated dibenzo-p-dioxins and dibenzofurans in the ambient air of Beijing, China. Atmos Environ 42:2037–2047

    Article  CAS  Google Scholar 

  • Mari M, Schuhmacher M, Feliubadalo J, Domingo JL (2008) Air concentrations of PCDD/Fs, PCBs and PCNs using active and passive air samplers. Chemosphere 70:1637–1643

    Article  CAS  Google Scholar 

  • Shoeib M, Harner T (2002) Characterization and comparison of three passive air samplers for persistent organic pollutants. Environ Sci Technol 36:4142–4151

    Article  CAS  Google Scholar 

  • Wennrich L, Popp P, Hafner C (2002) Novel integrative passive samplers for the long-term monitoring of semivolatile organic air pollutants. J Environ Monit 4:371–376

    Article  CAS  Google Scholar 

Download references

Acknowledgments

The work was supported by National High-tech R&D Program of China (2007AA061602, 2007AA06A407, 2009AA061603).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Minghui Zheng.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhang, B., Zhang, L., Wu, J. et al. An Active Sampler for Monitoring Polychlorinated Dibenzo-p-dioxins and Furans in Ambient Air. Bull Environ Contam Toxicol 87, 1–5 (2011). https://doi.org/10.1007/s00128-011-0287-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00128-011-0287-y

Keywords

Navigation