Abstract
An active sampler for monitoring polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) in air was developed using an automobile air filter set. The performance of the mobile air sampler was evaluated. Recoveries of PCDD/F congeners ranged from 62.3% to 64.5% with sampling volumes of 500–1,800 m3. Air samples were collected between April and June, 2007 in Beijing. The monitoring results of PCDD/F levels by the mobile sampler were comparable to results obtained by a conventional stationary high-volume active sampler. The results suggest this mobile air sampling technology is a promising new strategy for the assessment of air quality in urban areas.
Similar content being viewed by others
References
Chang H, Wang S, Wang Y, Li H, Wang L (2010) Contributions of dry and wet depositions of polychlorinated dibenzo-p-dioxins and dibenzofurans to a contaminated site resulting from a penetachlorophenol manufacturing process. Environ Monit Assess (in press). doi:10.1007/s10661-010-1545-x
Chao MR, Hu CW, Chen YL, Chang-Chien GP, Lee WJ, Chang LW, Lee WS, Wu KY (2004) Approaching gas-particle partitioning equilibrium of atmospheric PCDD/Fs with increasing distance from an incinerator: measurements and observations on modeling. Atmos Environ 38:1501–1510
Clarkson PJ, Larrazabal-Moya D, Staton I, McLeod CW, Ward DB, Sharifi VN, Swithenbank J (2002) The use of tree bark as a passive sampler for polychlorinated dibenzo-p-dioxins and furans. Int J Environ Anal Chem 82:843–850
Klanova J, Kohoutek J, Hamplova L, Urbanova P, Holoubek I (2006) Passive air sampler as a tool for long-term air pollution monitoring: Part 1. Performance assessment for seasonal and spatial variations. Environ Pollut 144:393–405
Li YM, Jiang GB, Wang YW, Cai ZW, Zhang QH (2008) Concentrations, profiles and gas-particle partitioning of polychlorinated dibenzo-p-dioxins and dibenzofurans in the ambient air of Beijing, China. Atmos Environ 42:2037–2047
Mari M, Schuhmacher M, Feliubadalo J, Domingo JL (2008) Air concentrations of PCDD/Fs, PCBs and PCNs using active and passive air samplers. Chemosphere 70:1637–1643
Shoeib M, Harner T (2002) Characterization and comparison of three passive air samplers for persistent organic pollutants. Environ Sci Technol 36:4142–4151
Wennrich L, Popp P, Hafner C (2002) Novel integrative passive samplers for the long-term monitoring of semivolatile organic air pollutants. J Environ Monit 4:371–376
Acknowledgments
The work was supported by National High-tech R&D Program of China (2007AA061602, 2007AA06A407, 2009AA061603).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zhang, B., Zhang, L., Wu, J. et al. An Active Sampler for Monitoring Polychlorinated Dibenzo-p-dioxins and Furans in Ambient Air. Bull Environ Contam Toxicol 87, 1–5 (2011). https://doi.org/10.1007/s00128-011-0287-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00128-011-0287-y