Skip to main content
Log in

Does stress shielding occur with the use of long-stem prosthesis in total knee arthroplasty?

  • Knee
  • Published:
Knee Surgery, Sports Traumatology, Arthroscopy Aims and scope

Abstract

A retrospective study conducted to evaluate the possible occurrence of stress shielding with the use of long-stem tibial prosthesis in total knee arthroplasty. Forty-one patients were reviewed (twenty-three standard prosthesis, eighteen long-stem prosthesis) and forty-one unoperated knee of the contralateral limb). Patients underwent bone mineral density assessment with a dual-energy X-ray absorptiometry (DEXA) bone densitometer for the hip and bilateral knees. The mean time interval between surgery and the DEXA assessment was 87.7 months. There was no significant statistical difference (P > 0.05) in the bone mineral density patterns of the tibia with the use of either standard or long-stem prosthesis. The utilization of the long-stem prosthesis to off-load the tibia is not associated with any significant bone mineral density changes or stress shielding.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Abu-Rajab RB, Watson WS, Walker B, Roberts J, Gallacher SJ, Meek RM (2006) Peri-prosthetic bone mineral density after total knee arthroplasty. Cemented versus cementless fixation. J Bone Joint Surg Br 88(5):606–613

    Article  PubMed  CAS  Google Scholar 

  2. Ang KC, Das De S, Goh JCH, Low SL, Bose K (1997) Periprosthetic bone remodeling after cementless total hip replacement. J Bone Joint Surg Am 79(4):675–679

    Article  CAS  Google Scholar 

  3. Bach CM, Nogler M, Steingruber IE, Ogon M, Wimmer C, Gobel G, Krismer M (2002) Scoring systems in total knee arthroplasty. Clin Orthop 399:184–196

    Article  PubMed  Google Scholar 

  4. Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE (1992) Producing and avoiding stress shielding. Laboratory and clinical observations of non-cemented total hip arthroplasty. Clin Orthop 274:79–96

    PubMed  Google Scholar 

  5. Bourne RB, Finlay JB (1986) The influence of tibial component intra-medullary stems and implant cortex contact on the strain distribution of the proximal tibia following total knee arthroplasty. An invitro study. Clin Orthop 208:95–99

    PubMed  Google Scholar 

  6. Engh CA, McGovern TF, Bobyn JD, Harris WH (1992) A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. J Bone Joint Surg Am 74(7):1009–1120

    PubMed  CAS  Google Scholar 

  7. Engh CA Jr, McAuley JP, Sychterz CJ, Sacco ME, James PM, Cristi JS, Engh CA Sr (2000) The accuracy and reproducibility of radiographic assessment of stress-shielding. J Bone Joint Surg Am 82(10):1414–1419

    PubMed  Google Scholar 

  8. Engh GA, Herzwurm PJ, Parks NL (1997) Treatment of major defects of bone with bulk allografts and stemmed components during total knee arthroplasty. J Bone Joint Surg Am 79(7):1030–1039

    PubMed  CAS  Google Scholar 

  9. Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop 248:9–12

    PubMed  Google Scholar 

  10. Gofton WT, Tsigaras H, Butler RA, Patterson JJ, Barrack RL, Rorabeck CH (2002) Revision total knee arthroplasty. Fixation with modular stems. Clin Orthop 404:158–168

    Article  PubMed  Google Scholar 

  11. Hammerman D (1989) The biology of osteoarthritis. N Engl J Med 320:1322–1330

    Google Scholar 

  12. Hendel D, Velan GJ, Weisbort M (1997) Intra-articular tibial plateau stress fracture associated with osteoarthrosis and valgus knee deformity. J Arthroplasty 12(6):713–715

    Article  PubMed  CAS  Google Scholar 

  13. Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop 248:13–14

    PubMed  Google Scholar 

  14. Insall JN, Hood RW, Flawn LB, Sullivan DJ (1983) The total condylar knee prosthesis in gonarthrosis. A five to nine-year follow-up of the first one hundred consecutive replacements. J Bone Joint Surg Am 65(5):619–628

    PubMed  CAS  Google Scholar 

  15. Insall JN, Lachiewicz PF, Burstein AH (1982) The posterior stabilized condylar prosthesis: a modification of the total condylar design: two to four-year clinical experience. J Bone Joint Surg Am 64(9):1317–1323

    PubMed  CAS  Google Scholar 

  16. Insall JN, Ranawat CS, Aglietti P, Shine J (1976) A comparison of four models of total knee-replacement prosthesis. J Bone Joint Surg Am 58(6):754–765

    PubMed  CAS  Google Scholar 

  17. Insall J, Scott WN, Ranawat CS (1979) The total condylar knee prosthesis: a report of two hundred and twenty cases. J Bone Joint Surg Am 61(2):173–180

    PubMed  CAS  Google Scholar 

  18. Ishii Y, Yagisawa K, Ikezawa Y (2000) Changes in bone mineral density of the proximal femur after total knee arthroplasty. J Arthroplasty 15(4):519–522

    Article  PubMed  CAS  Google Scholar 

  19. Jazrawi LM, Bai B, Kummer FJ, Hiebert R, Stuchin SA (2001) The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty. J Arthroplasty 16(6):759–767

    Article  PubMed  CAS  Google Scholar 

  20. Li MG, Nilsson KG (2000) The effect of pre-operative bone quality on the fixation of the tibial component in total knee arthroplasty. J Arthroplasty 15(6):744–753

    Article  PubMed  CAS  Google Scholar 

  21. Lonner JH, Klotz M, Levitz C, Lotke PA (2001) Changes in bone density after cemented total knee arthroplasty. Influence of stem design. J Arthroplasty 16(1):107–111

    Article  PubMed  CAS  Google Scholar 

  22. McCarthy CK, Steinberg GG, Agren M, Leahey D, Wyman E, Baran DT (1991) Quantifying bone loss from the proximal femur after total hip arthroplasty. J Bone Joint Surg Br 73(5):774–778

    PubMed  CAS  Google Scholar 

  23. Mont MA, Rifai A, Baumgarten KM, Sheldon M, Hungerford DS (2002) Total knee arthroplasty for osteonecrosis. J Bone Joint Surg Am 84(4):599–603

    PubMed  Google Scholar 

  24. Mow VC, Hayes WC (1997) Basic orthopaedic biomechanics, 2nd edn. Lippincott Williams & Wilkins, Philadelphia, pp 429–430

    Google Scholar 

  25. Murray PB, Rand JA, Hanssen AD (1994) Cemented long-stem revision total knee arthroplasty. Clin Orthop 309:116–123

    PubMed  Google Scholar 

  26. Ortego-Centeno N, Munoz-Torres M, Jodar E, Hernandez-Quero J, Jurado-Duce A, de la Higuera Torres-Puchol J (1997) Effect of tobacco consumption on bone mineral density in healthy young males. Calcif Tissue Int 60(6):496–500

    Article  PubMed  CAS  Google Scholar 

  27. Peyron JG (1986) Osteoarthritis. Clin Orthop 213:13–19

    PubMed  Google Scholar 

  28. Reilly D, Walker PS, Ben-Dov M, Ewald FC (1982) Effects of tibial components on load transfer in the upper tibia. Clin Orthop 165:273–282

    PubMed  Google Scholar 

  29. Roesler H (1987) The history of some fundamental concepts in bone biomechanics. J Biomech 20(11/12):1025–1034

    Article  PubMed  CAS  Google Scholar 

  30. Roffi RP, Merritt PO (1990) Total knee replacement after fractures about the knee. Orthop Rev 19:614–620

    PubMed  CAS  Google Scholar 

  31. Sambrook P, Raj A, Hunter D, Naganathan V, Mason R, Robinson B (2001) Osteoporosis with low dose corticosteroids. Contribution of underlying disease effects and discriminatory ability of ultrasound versus bone densitometry. J Rheumatol 28(5):1063–1067

    PubMed  CAS  Google Scholar 

  32. Sawant MR, Bendall SP, Kavanagh TG, Citron ND (1999) Non-union of tibial stress fractures in patients with deformed arthritic knees. J Bone Joint Surg Br 81(4):663–666

    Article  PubMed  CAS  Google Scholar 

  33. Soininvaara T, Kröger H, Jurvelin JS, Miettinen H, Suomalainen O, Alhava E (2000) Measurement of bone density around total knee arthroplasty using fan-beam dual energy X-ray absorptiometry. Calcif Tissue Int 67(3):267–272

    Article  PubMed  CAS  Google Scholar 

  34. Soininvaara TA, Miettinen HJ, Jurvelin JS, Suomalainen OT, Alhava EM, Kröger HP (2004) Periprosthetic femoral bone loss after total knee arthroplasty: 1-year follow-up study of 69 patients. Knee 11(4):297–302

    Article  PubMed  Google Scholar 

  35. Soininvaara TA, Miettinen HJ, Jurvelin JS, Suomalainen OT, Alhava EM, Kröger HP (2004) Periprosthetic tibial bone mineral density changes after total knee arthroplasty: one-year follow-up study of 69 patients. Acta Orthop Scand 75(5):600–605

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sathappan S. Sathappan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sathappan, S.S., Pang, HN., Manoj, A. et al. Does stress shielding occur with the use of long-stem prosthesis in total knee arthroplasty?. Knee Surg Sports Traumatol Arthrosc 17, 179–183 (2009). https://doi.org/10.1007/s00167-008-0649-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00167-008-0649-0

Keywords

Navigation