Skip to main content

Advertisement

Log in

Prediction of extreme ozone levels in Barcelona, Spain

  • Published:
Environmental Monitoring and Assessment Aims and scope Submit manuscript

Abstract

Barcelona is one of the most polluted cities in Western Europe, although our levels of air pollution are within the World Health Organisation air quality guidelines. However, high concentrations of air pollution have not been studied yet. Ground ozone levels is a topic of considerable environmental concern, since excessive level of ozone are taken as indicative of high pollution. In terms of the air quality guidelines ozone levels higher than 100 µg m−3 can start to be health-hazards for human health. Our objective is to report a detailed analysis of ozone data exceeding the thresholds established by the air quality guidelines. Data analysed were collected in two measurement stations in Barcelona, for the reference period 1991–1996. Applying statistical techniques commonly used in the analysis of extreme values, mainly the Peak Over Threshold method was used for in this study. The analysis reveal that the ozone threshold values for the protection of human health has exceeded many times in both stations. The estimated return values for 3, 10, and 40 yr exceed the threshold value for information to the public of almost once in both stations, also it seems to be unlikely that the threshold value for warning to the public will be exceeded in 40 yr.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • M. Aceves J. Grimalt (1993) ArticleTitleLarge and small particle size screening of organic compounds in urban air Atmos. Environ. 27 251–3 Occurrence Handle10.1016/0957-1272(93)90010-4

    Article  Google Scholar 

  • S. G. Coles F. Pan (1996) ArticleTitleThe analysis of extreme pollution levels: A case study J. Appl. Stats. 23 333–348

    Google Scholar 

  • A. C. Davison R..L. Smith (1990) ArticleTitleModel for exceedances over high thresholds (with discussion) J. Roy. Statist. Soc. Ser. B 52 343–442

    Google Scholar 

  • J. Horowitz (1980) ArticleTitleExtremes values for a non-stationary stochastic processes: An application to air quality analysis Technometrics 22 469–478

    Google Scholar 

  • X. F. Nui (1997) ArticleTitleExtreme value for a class of non-stationary time series with applications Ann. Appl. Probab. 7 508–522

    Google Scholar 

  • N. D. Singpurwalla (1972) ArticleTitleExtreme from a log-normal law with applications to air pollution problems Technometrics 14 703–711

    Google Scholar 

  • R..L. Smith (1989) ArticleTitleExtreme value analysis of environmental time series: An application to trend detection in ground-level ozone Statist. Science 4 367–393

    Google Scholar 

  • H. Vaquera-Huerta J. A. Villasenor J. Hughes (1997) Statistical Analysis of Trends in Urban Ozone V. Barnett K. F. Turkman (Eds) Statistics for the Environment 3: Pollution Assessment and Control John Wiley & Sons New York 175–184

    Google Scholar 

  • InstitutionalAuthorNameWHO - World Health Organisation (1987) Air Quality Guidelines for Europe NumberInSeries23 WHO Copenhagen

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Aurelio Tobías.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tobías, A., Scotto, M.G. Prediction of extreme ozone levels in Barcelona, Spain. Environ Monit Assess 100, 23–32 (2005). https://doi.org/10.1007/s10661-005-7057-4

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10661-005-7057-4

Keywords

Navigation