Skip to main content

Advertisement

Log in

Transmission Through and Breakage of Multi-Pane Glazing Due to Radiant Exposure

  • Published:
Fire Technology Aims and scope Submit manuscript

Abstract

A series of small and large-scale tests were performed to measure the radiant transmission of energy and the window breakage characteristics of seven different multi-plane glazing samples. The samples tested included both double and triple-pane glazing specimens with a laminate interlayer between panes for additional strength. These test series were designed to provide the information necessary to assess the hazard from radiant energy to building occupants and contents due to a large fire in close proximity to a structure with a large amount of exterior windows. For incident heat fluxes 30 kW/m2 or lower, the triple-pane glazing samples had a total transmittance less than 10% of the incident heat flux, back-side surface temperatures did not exceed 100°C, and the back-side heat flux did not exceed 4 kW/m2. For double-pane laminates, the total transmittance was less than 25% of the incident heat flux, the back-side temperature did not exceed 220°C, and the back-side heat flux did not exceed 5 kW/m2. For incident heat fluxes greater than 30 kW/m2, the glazing samples degraded very quickly, generally buckling and losing integrity. The time for the first pane to crack decreased with increasing incident flux level. A number of tests included a water deluge system, which served to maintain sample integrity for extended exposures. In these cases, the total transmittance was less than 6% of the incident heat flux, back-side surface temperatures did not exceed 45°C, and the back-side heat flux did not exceed 1 kW/m2.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. NFPA 415, “Standard on Airport Terminal Buildings, Fueling Ramp Drainage, and Loading Walkways,” National Fire Protection Association, Quincy, MA, 2002.

  2. H.W. Emmons, “The Needed Fire Science,” in Fire Safety Science—Proceedings of the Fire International Symposium, C.E. Grant and P.J. Pagni (eds.) Hemisphere, Washington, D.C., 1986, pp. 33–53.

    Google Scholar 

  3. P.K. Barth and H. Sung, “Glass Fracture under Intense Heating,” Senior Project, Harvard University, Cambridge, MA, 1977.

  4. P.J. Pagni, “Fire Physics—Promises, Problems, and Progress,” in Fire Safety Science—Proceedings of the Second International Symposium, C.E. Grant and P.J. Pagni (eds.) Hemisphere, Washington, D.C., 1988, pp. 49–66.

    Google Scholar 

  5. P.J. Pagni and A.A. Joshi, “Glass Breaking in Fires,” in Fire Safety Science—Proceedings of the Third International Symposium, G. Cox and B. Longford (eds.) Hemisphere, Washington, D.C., 1991, pp. 791–802.

    Google Scholar 

  6. A.A. Joshi and P.J. Pagni, “Fire-Induced Thermal Fields in Window Glass. I—Theory,” Fire Safety Journal, 22(1), 1994, pp. 25–43.

    Article  Google Scholar 

  7. A.A. Joshi and P.J. Pagni, “Fire-Induced Thermal Fields in Window Glass. II— Experiments,” Fire Safety Journal, vol. 22, no. 1, 1994, pp. 45–65.

    Article  Google Scholar 

  8. O. Keski-Rahkomen, “Breaking of Window Glass Close to Fire,” Fire and Materials, vol. 12, 1988, pp. 61–69.

    Article  Google Scholar 

  9. O. Keski-Rahkomen, “Breaking of Window Glass Close to Fire, II: Circular Panes,” Fire and Materials, vol. 15, 1991, pp. 11–16.

    Article  Google Scholar 

  10. M.J. Skelly, R.J. Roby, and C.L. Beyler, “An Experimental Investigation of Glass Breakage in Compartment Fires,” Journal of Fire Protection Engineering, vol. 3, no. 1, 1991, pp. 24–34.

    Google Scholar 

  11. G.W. Silcock and Shields, “An Experimental Evaluation of Glazing in Compartment Fires,” Interflam, vol. 93, 1993, pp. 747–756.

    Google Scholar 

  12. T.J. Shields, G.W.H. Silcock, and F. Flood, “Performance of a Single Glazing Assembly Exposed to Enclosure Corner Fires of Increasing Severity,” Fire and Materials, vol. 25, 2001, pp. 123–152.

    Article  Google Scholar 

  13. F.W. Mowrer, “Window Breakage Induced by Exterior Fires,” National Institutes of Standards and Technology, NIST-GCR-98-751, 1998.

  14. J.D. Cohen and P. Wilson, “Current Results from Structure Ignition Assessment Model (SIAM) Research,” Fire Management in the Wildland/Urban Interface: Sharing Solutions, Alberta, Canada, 1994.

    Google Scholar 

  15. N.A. McArthur, “The Performance of Aluminum Building Products in Bushfires,” Fire and Materials, vol. 15, 1991, pp. 117–125.

    Article  Google Scholar 

  16. K. Harada, A. Enomoto, K. Uede, and T. Wakamatsu, “Experimental Study on Glass Cracking and Fallout by Radiant Heat Exposure,” in Fire Safety Science—Proceedings of the Sixth International Symposium, M. Curtat (eds.) IAFSS, 2000, pp. 1063–1074.

  17. B.R. Cuzillo and P.J. Pagni, “Thermal Breakage of Double-Pane Glazing by Fire,” Journal of Fire Protection Engineering, vol. 9, 1998, pp. 1–11.

    Google Scholar 

  18. G.S. Cowles, “The Attenuation of Radiation from Building Fires through Fire-resistant Glazing,” Fire Safety Science—Proceedings of the Fifth International Symposium, 1997, p. 1357.

  19. ASTM E 1321-97a, “Standard Test Method for Determining Material Ignition and Flame Spread Properties,” American Society for Testing and Materials, Philadelphia, PA, 1997.

  20. R. Siegel and J.R. Howell, Thermal Radiation Heat Transfer, (2nd edition), Hemisphere Publishing Corporation, New York, 1982, pp. 727–730.

    Google Scholar 

  21. D.A. Purser, “Toxicity Assessment of Combustion Products,” The SFPE Handbook of Fire Protection Engineering, 2nd edition, 1995.

  22. K. Mudan and P. Croce, “Fire Hazard Calculations for Large Open Hydrocarbon Fires,” The SFPE Handbook of Fire Protection Engineering, 2nd edition, 1995.

  23. P.H. Thomas, “The Size of Flames from Natural Fires,” in 9thInternational Combustion Symposium, Combustion Institute, Pittsburgh, PA, pp. 844–859, 1963.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Klassen, M.S., Sutula, J.A., Holton, M.M. et al. Transmission Through and Breakage of Multi-Pane Glazing Due to Radiant Exposure. Fire Technol 42, 79–107 (2006). https://doi.org/10.1007/s10694-006-7254-x

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10694-006-7254-x

Key Words

Navigation