Abstract
Purpose
The aim of this study was to improve the contrast-to-noise ratio on noncontrast head computed tomography (CT) images, which are crucial for assessing patients with acute ischemic stroke. We applied a technique combining volume helical scanning with a three-dimensional (3D) denoising filter.
Materials and methods
We scanned phantoms for low-contrast resolutions and helical/cone-beam artifacts as well as stroke patients using a 16-row multidetector-row CT (MDCT) unit. Volume helical scans with 1-mm collimation and nonhelical scans with 8-mm thickness were performed. From the 1-mm thick volume data, 8-mm thick contiguous images were generated before and after applying a 3D denoising filter.
Results
On images stacked from volume data, the contrast-to-noise ratio was significantly improved by the 3D denoising filter and was nearly the same as that on nonhelical images. On stacked volume images, artifacts due to the cone beam and the helical scan were increased with larger helical pitches, but bone-related streak artifacts in the posterior fossa and underneath the calvarium were reduced when compared with nonhelical images.
Conclusion
Volume helical scan with a 3D denoising filter effectively improves image quality in noncontrast head MDCT images.
Similar content being viewed by others
References
M Hu (1999) ArticleTitleMulti-slice helical CT: scan and reconstruction Med Phys 26 5–18 Occurrence Handle9949393 Occurrence Handle10.1118/1.598470 Occurrence Handle1:STN:280:DyaK1M7jsVGmsA%3D%3D
T Sasaki T Hanari M Sasaki H Oikawa H Gakumazawa M Okumura et al. (2004) ArticleTitleReduction of radiation exposure in CT perfusion study using a quantum de-noising filter Nippon Hoshasen Gijutsu Gakkai Zasshi 60 1688–93 Occurrence Handle15614220
M Okumura T Ota S Tsukagoshi K Katada (2006) ArticleTitleNew method of evaluating edge-preserving adaptive filters for computed tomography: digital phantom method Nippon Hoshasen Gijutsu Gakkai Zasshi 62 971–8 Occurrence Handle16874286
E Nishimaru R Utsunomiya A Nishie Y Ninomiya Y Tomoshige (2005) ArticleTitleA new method of evaluating helical artifact by image subtraction technique Nippon Hoshasen Gijutsu Gakkai Zasshi 61 1021–6 Occurrence Handle16049416
R von Kummer H Bourquain S Bastianello L Bozzao C Manelfe D Meier et al. (2001) ArticleTitleEarly prediction of irreversible brain damage after ischemic stroke at CT Radiology 219 95–100 Occurrence Handle11274542 Occurrence Handle1:STN:280:DC%2BD3M7oslKlsQ%3D%3D
H Adams R Adams G Del Zoppo LB Goldstein (2005) ArticleTitleGuidelines for the early management of patients with ischemic stroke: 2005 guideline update Stroke 36 916–21 Occurrence Handle15800252 Occurrence Handle10.1161/01.STR.0000163257.66207.2d
C Tanaka T Ueguchi E Shimosegawa N Sasaki T Johkoh H Nakamura et al. (2006) ArticleTitleEffect of CT acquisition parameters in the detection of subtle hypoattenuation in acute cerebral infarction: a phantom study AJNR Am J Neuroradiol 27 40–5 Occurrence Handle16418353 Occurrence Handle1:STN:280:DC%2BD28%2FivF2ktg%3D%3D
G Wang MW Vannier (1999) ArticleTitleThe effect of pitch in multislice spiral/helical CT Med Phys 26 2648–53 Occurrence Handle10619250 Occurrence Handle10.1118/1.598804 Occurrence Handle1:STN:280:DC%2BD3c%2FosValug%3D%3D
M Prokop (2003) General principles of multidetector computed tomography L Bonomo D Foley H Imhof G Rubin (Eds) Multidetector computed tomography technology: advances in imaging techniques EditionNumber1st edition Royal Society of Medicine Press London 3–23
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Sasaki, T., Sasaki, M., Hanari, T. et al. Improvement in image quality of noncontrast head images in multidetector-row CT by volume helical scanning with a three-dimensional denoising filter. Radiat Med 25, 368–372 (2007). https://doi.org/10.1007/s11604-007-0145-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11604-007-0145-3