Skip to main content

Advertisement

Log in

Energy efficiency and indoor thermal perception: a comparative study between radiant panel and portable convective heaters

  • Published:
Energy Efficiency Aims and scope Submit manuscript

Abstract

This study investigates experimentally the thermal perception of indoor environment for evaluating the ability of radiant panel heaters to produce thermal comfort for space occupants as well as the energy consumption in comparison with conventional portable natural convective heaters. The thermal perception results show that, compared with conventional convection heater, a radiantly heated office room maintains a lower ambient air temperature while providing equal levels of thermal perception on the thermal dummy head as the convective heater and saves up to 39.1% of the energy consumption per day. However, for human subjects’ vote experiments, the results show that for an environmentally controlled test room at outdoor environment temperatures of 0°C and 5°C, using two radiant panel heaters with a total capacity of 580 W leads to a better comfort sensation than the conventional portable natural convective heater with a 670 W capacity, with an energy saving of about 13.4%. In addition, for an outdoor environment temperature of 10°C, using one radiant panel heater with a capacity of 290 W leads to a better comfort sensation than the conventional convection heater with a 670 W capacity, with an energy saving of about 56.7%. From the analytical results, it is found that distributing the radiant panel heater inside the office room, one on the wall facing the window and the other on the wall close to the window, provides the best operative temperature distribution within the room.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12

Similar content being viewed by others

Abbreviations

A :

surface area, m2

c p :

specific heat, J/kg K

F :

radiation configuration (shape) factor

h :

heat transfer coefficient, W/m2 K

H :

room height, m

\({\dot m}\) :

mass flow rate, kg/s

N :

number of surface elements number, -

q :

heat flux, W/m2

Q :

heat transfer, W

R th :

thermal resistance, m2 K/ W

T :

temperature, K or °C

X :

axial horizontal distance, m, -

y :

axial vertical distance, m, -

Z :

axial distance, m, -

ε :

emittance

ρ :

reflectance

σ :

Stefan–Boltzmann constant, (5.67051 × 10-8), W/m2 K4

a:

air

cnd:

conduction

cnv:

convection

i:

element i

if:

infiltration

j:

element j

o:

operative temperature

outd:

outdoor

rad:

radiation

References

  • Ali, A., Ahmed Hamza, H., Morsy, MG., Taha, IS., Hamza, M. (2007). Experimental investigation of comfort sensation and performance of radiant heating panel compared with conventional oil heater. Proc 3rd Int Conf Therm Eng (ICTEA7) Theory and Applications, Amman, Jordan, 635–640.

  • ANSI/ASHRAE Standard 55. (1992). Thermal environmental conditions for human occupancy. Atlanta: American Society of Heating Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • Ardehali, M. M., Panah, N. G., & Smith, T. F. (2004). Proof of concept modeling of energy transfer mechanisms for radiant conditioning panels. Energy Conversion and Management, 45, 2005–2017.

    Article  Google Scholar 

  • ASHRAE. (2004). HVAC applications handbook, panel heating and cooling, chap.6. Atlanta: American Society of Heating Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • ASHRAE. (2005). Fundamentals handbook, thermal comfort, chap.8. Atlanta: American Society of Heating Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • Baskin, E. (2003). Residential radiant cooling and heating assessment. Project 4.3.6a, final report (p. 22). Tennessee: Oak Ridge National Laboratory.

    Google Scholar 

  • Chapman, K. S., & Zhang, P. (1995). Radiant heat exchange calculations in radiantly heated and cooled enclosures. ASHRAE Transactions, 101(1), 1236–1247.

    Google Scholar 

  • Chapman, K. S., & Zhang, P. (1996). Energy transfer simulation for radiantly heated and cooled enclosures. ASHRAE Transactions, 102(1), 76–85.

    Google Scholar 

  • Chapman, K. S., DeGreef, J. M., & Watson, R. D. (1997). Thermal comfort analysis using BCAP for retrofitting a radiantly heated residence. ASHRAE Transactions, 103(1), 959–965.

    Google Scholar 

  • Chapman, K. S., & DeGreef, J. M. (1997). Design factor development to obtain thermal comfort with combined radiant and convective in-space heating and cooling systems. Final report of ASHRAE Project RP-907. Atlanta: ASHRAE.

    Google Scholar 

  • DeGreef, J., & Chapman, K. S. (1998). Simplified thermal comfort evaluation of MRT gradients and power consumption predicted with the BCAP methodology. ASHRAE Transactions, 104(1), 1090–1097.

    Google Scholar 

  • Hanibuchi, H., & Hokoi, S. (2000). Simplified method of estimating efficiency of radiant and convective heating systems. ASHRAE Transactions, 106(1), 487–494.

    Google Scholar 

  • Howell, J. R. (2001). A catalog of radiation heat transfer configuration factors. In R. Siegel & J. R. Howell (Eds.), Thermal radiation heat transfer (4th ed.). New York: Taylor and Francis.

    Google Scholar 

  • Imanari, T., Omori, T., & Bogaki, K. (1999). Thermal comfort and energy consumption of the radiant ceiling panel system comparison with the conventional all-air system. Energy and Buildings, 30, 167–175.

    Article  Google Scholar 

  • Jones, B. (1998). Radiant heat transfer between the human body and its surroundings. ASHRAE Transactions, 104(2), 1340–1349.

    Google Scholar 

  • Jones, B., Chapman, KS. (1994). Simplified method to factor mean radiant temperature (MRT) into building and hvac system design. Final Report of ASHRAE Research Project RP-657

  • Kalisperis, L. N., Steinman, M., & Summers, L. H. (1991). An energy evaluative comparison of a thermal comfort design model (pp. 611–618). Nice, France: Proc of BS’91.

    Google Scholar 

  • Laouadi, A. (2004). Development of a radiant heating and cooling model for building energy simulation software. Building and Environment, 39, 421–431.

    Article  Google Scholar 

  • Miriel, J., Serres, L., & Trombe, A. (2002). Radiant ceiling panel heating–cooling systems: experimental and simulated study of the performances, thermal comfort and energy consumptions. Applied Thermal Engineering, 22, 1861–1873.

    Article  Google Scholar 

  • NAHB Research Center. (1994). Enerjoy case study, an evaluation of thermal comfort and energy consumption for the enerjoy radiant panel heating system. Final Report Project No. 4159 (p. 66). Upper Marlboro: NAHB. MD 20772.

    Google Scholar 

  • Press, WH., Teukolsky, SA., Vetterling, WT., Flannery, BP. (1997). Numerical recipes in Fortran 77-the art of scientific computing. 2nd Ed, Vol 1 of FORTRAN Numerical Recipes, Press Syndicate of the University of Cambridge.

  • Scheatzle, D. G. (2003). Data set for validating simulation tools for radiant/convective systems. ASHRAE Transactions, 109(2), 557–571.

    Google Scholar 

  • Siegel, R., & Howell, J. R. (2001). Thermal radiation heat transfer (4th ed.). New York: Taylor and Francis.

    Google Scholar 

  • Strand, R. K., & Baumgartner, K. T. (2005). Modeling radiant heating and cooling systems: integration with a whole-building simulation program. Energy and Buildings, 37, 389–397.

    Article  Google Scholar 

  • Tassou, S. A., Xiang, W., & Kollokotroni, M. (2000). Church heating: numerical modelling and comparison between radiant and forced convection systems. ASHRAE Transactions, 106(1), 495–505.

    Google Scholar 

  • Wang, W., Chapman, K. S., & Keshavarz, A. (2005). Incorporate radiant heaters over 300°F into thermal comfort calculations using BCAP. ASHRAE Transactions, 111(1), 346–354.

    Google Scholar 

  • Zmeureanu, R., Iliescu, S., Dauce, D., & Jacob, Y. (2003). Radiation from cold or warm windows: computer model development and experimental validation. Building and Environment, 38, 427–434.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ahmed Hamza H. Ali.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ali, A.H.H., Gaber Morsy, M. Energy efficiency and indoor thermal perception: a comparative study between radiant panel and portable convective heaters. Energy Efficiency 3, 283–301 (2010). https://doi.org/10.1007/s12053-010-9077-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12053-010-9077-3

Keywords

Navigation