Applicability of high-temperature cooling systems in different European countries from the view of the condensation risk

  • Research Article
  • Building Systems and Components
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Due to the different approaches in determining the ventilation airflow rate per person for workspaces, where high-temperature air conditioning systems are used for air conditioning, problems with the condensation of water vapour on the cold surfaces of the system can occur. The article analyses the risk of condensation in various European cities using the available climatic data. Systems with cooling ceilings and cooling beams with a ventilation device operating in parallel are taken into account. Different ventilation airflow rates per person were analysed. On the example of a room equipped with high-temperature cooling, an energy simulation calculation is performed, which includes a ventilation and air-conditioning system with the possibility of capacity control. It is clear from the results that the condensation of water vapour can be prevented by technical measures at the cost of reducing the cooling capacity, which can affect the achievement of the thermal comfort of those present. In the end, suitable solutions are discussed, which should already be adopted at the time the device is designed so that the risk of condensation is not a major obstacle in the operation of these energy-efficient systems. An irreplaceable role in the operation of high-temperature cooling systems is played by a measurement and control system with a suitable algorithm to prevent condensation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

c :

specific heat [J/(kg·K)]

CR:

condensation risk [%]

h :

enthalpy [kJ/kg]

:

mass flow rate [kg/s]

MRT:

mean radiant temperature [°C]

PMV:

predicted mean vote [—]

\(\dot V\) :

volume airflow rate [m3/h]

\(\dot Q\) :

heat flux [W]

RH:

relative humidity [%]

t :

temperature [°C]

W :

humidity ratio [g/kg]

ρ :

air density [kg/m3]

a:

air

c:

cooling coil

crit:

critical

dp:

dew point

i:

indoor

lat:

latent

o:

outdoor

p :

person

sen:

sensible

s:

supply

v:

water vapour

w:

water

wb:

wet bulb

w1:

inlet water

w2:

return water

References

  • Amini M, Maddahian R, Saemi S (2020). Numerical investigation of a new method to control the condensation problem in ceiling radiant cooling panels. Journal of Building Engineering, 32: 101707.

    Article  Google Scholar 

  • ASHRAE (2009). ASHRAE Handbook: Fundamentals. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • ASHRAE (2013). ASHRAE Standard 62.1. Ventilation for Acceptable Indoor Air Quality. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • Chung WJ, Lim JH (2019). Cooling operation guidelines of thermally activated building system considering the condensation risk in hot and humid climate. Energy and Buildings, 193: 226–239.

    Article  Google Scholar 

  • EN 13779 (2010). Ventilation for Non-Residential Buildings—Performance Requirements for Ventilation and Room-Conditioning Systems. European Committee for Standardization.

  • Ge G, Xiao F, Wang S (2012). Neural network based prediction method for preventing condensation in chilled ceiling systems. Energy and Buildings, 45: 290–298.

    Article  Google Scholar 

  • Hao X, Zhang G, Chen Y, et al. (2007). A combined system of chilled ceiling, displacement ventilation and desiccant dehumidification. Building and Environment, 42: 3298–3308.

    Article  Google Scholar 

  • Inkster T, Peters C, Soulsby H (2020). Potential infection control risks associated with chilled beam technology: Experience from a UK hospital. Journal of Hospital Infection, 106: 613–616.

    Article  Google Scholar 

  • Jin W, Jia L, Wang Q, et al. (2015). Study on condensation features of radiant cooling ceiling. Procedia Engineering, 121: 1682–1688.

    Article  Google Scholar 

  • Jin W, Jia L, Gao P, et al. (2017). The moisture content distribution of a room with radiant ceiling cooling and wall-attached jet system. Building Simulation, 10: 41–50.

    Article  Google Scholar 

  • Jin W, Ma J, Bi C, et al. (2020). Dynamic variation in dew-point temperature of attached air layer of radiant ceiling cooling panels. Building Simulation, 13: 1281–1290.

    Article  Google Scholar 

  • Kim MK, Liu J, Cao S (2018). Energy analysis of a hybrid radiant cooling system under hot and humid climates: A case study at Shanghai in China. Building and Environment, 137: 208–214.

    Article  Google Scholar 

  • Lim JH, Jo JH, Kim YY, et al. (2006). Application of the control methods for radiant floor cooling system in residential buildings. Building and Environment, 41: 60–73.

    Article  Google Scholar 

  • Mumma SA (2003). Chilled ceiling condensation control. ASHRAE IAQ Applications, 4(4): 22–23.

    Google Scholar 

  • Niu JL, Zhang LZ, Zuo HG (2002). Energy savings potential of chilled-ceiling combined with desiccant cooling in hot and humid climates. Energy and Buildings, 34: 487–495.

    Article  Google Scholar 

  • Novoselac A, Srebric J (2002). A critical review on the performance and design of combined cooled ceiling and displacement ventilation systems. Energy and Buildings, 34: 497–509.

    Article  Google Scholar 

  • Pieskä H, Ploskić A, Wang Q (2020). Design requirements for condensation-free operation of high-temperature cooling systems in Mediterranean climate. Building and Environment, 185: 107273.

    Article  Google Scholar 

  • Recknagel H, Schramek E-R, Sprenger E (2007). Taschenbuch für Heizung und Klimatechnik. München: Oldenbourg Industrieverlag. (in German)

    Google Scholar 

  • Rhee KN, Kim KW (2015). A 50 year review of basic and applied research in radiant heating and cooling systems for the built environment. Building and Environment, 91: 166–190.

    Article  Google Scholar 

  • Rhee KN, Olesen BW, Kim KW (2017). Ten questions about radiant heating and cooling systems. Building and Environment, 112: 367–381.

    Article  Google Scholar 

  • Saber EM, Iyengar R, Mast M, et al. (2014). Thermal comfort and IAQ analysis of a decentralized DOAS system coupled with radiant cooling for the tropics. Building and Environment, 82: 361–370.

    Article  Google Scholar 

  • Saber EM, Tham KW, Leibundgut H (2016). A review of high temperature cooling systems in tropical buildings. Building and Environment, 96: 237–249.

    Article  Google Scholar 

  • Sekhar C, Zheng L (2018). Study of an integrated personalized ventilation and local fan-induced active chilled beam air conditioning system in hot and humid climate. Building Simulation, 11: 787–801.

    Article  Google Scholar 

  • Song D, Kim T, Song S, et al. (2008). Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation. Applied Thermal Engineering, 28: 1299–1311.

    Article  Google Scholar 

  • Tang H, Liu X, Jiang Y (2016a). Theoretical and experimental study of condensation rates on radiant cooling surfaces in humid air. Building and Environment, 97: 1–10.

    Article  Google Scholar 

  • Tang H, Liu X, Li H, et al. (2016b). Study on the reduction of condensation risks on the radiant cooling ceiling with superhydrophobic treatment. Building and Environment, 100: 135–144.

    Article  Google Scholar 

  • Teodosiu C, Ilie V, Teodosiu R (2016). Numerical prediction of thermal comfort and condensation risk in a ventilated office, equipped with a cooling ceiling. Energy Procedia, 85: 550–558.

    Article  Google Scholar 

  • Virta M, Butler D, Graslund J, et al. (2004). Chilled beam Application Guidebook. Brussels: REHVA.

    Google Scholar 

  • Yin YL, Wang RZ, Zhai XQ, et al. (2014). Experimental investigation on the heat transfer performance and water condensation phenomenon of radiant cooling panels. Building and Environment, 71: 15–23.

    Article  Google Scholar 

  • Zhang LZ, Niu JL (2003). Indoor humidity behaviors associated with decoupled cooling in hot and humid climates. Building and Environment, 38: 99–107.

    Article  Google Scholar 

  • Zhang C, Heiselberg PK, Chen Q, et al. (2017). Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system. Building Simulation, 10: 203–218.

    Article  Google Scholar 

  • Zhang Y, Wu Z, Zhang M, et al. (2018). Smart indoor humidity and condensation control in the spring in hot-humid areas. Building and Environment, 135: 42–52.

    Article  Google Scholar 

  • Zmrhal V (2014). Condensation risk in high-temperature air-conditioning systems. Heating, Ventilation, Sanitation, 23(2): 76–80. (in Czech)

    Google Scholar 

  • Zmrhal V (2017). Heat gains from the people as a basis of energy simulation. Heating, Ventilation, Sanitation, 26(4): 234–239. (in Czech)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Vladimír Zmrhal.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zmrhal, V., Barták, M. Applicability of high-temperature cooling systems in different European countries from the view of the condensation risk. Build. Simul. 14, 1453–1466 (2021). https://doi.org/10.1007/s12273-020-0753-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-020-0753-8

Keywords

Navigation