Skip to main content
Log in

Numerical modelling on pulsatile flow of Casson nanofluid through an inclined artery with stenosis and tapering under the influence of magnetic field and periodic body acceleration

  • Articles
  • Published:
Korea-Australia Rheology Journal Aims and scope Submit manuscript

Abstract

The present study investigates the pulsatile flow of Casson nanofluid through an inclined and stenosed artery with tapering in the presence of magnetic field and periodic body acceleration. The iron oxide nanoparticles are allowed to flow along with it. The governing equations for the flow of Casson fluid when the artery is tapered slightly having mild stenosis are highly non-linear and the momentum equations for temperature and concentration are coupled and are solved using finite difference numerical schemes in order to find the solutions for velocity, temperature, concentration, wall shear stress, and resistance to blood flow. The aim of the present study is to analyze the effects of flow parameters on the flow of nanofluid through an inclined arterial stenosis with tapering. These effects are represented graphically and concluded that the wall shear stress profiles enhance with increase in yield stress, magnetic field, thermophoresis parameter and decreases with Brownian motion parameter, local temperature Grashof number, local nanoparticle Grashof number. The significance of the model is the existence of yield stress and it is examined that when the rheology of blood changes from Newtonian to Casson fluid, the percentage of decrease in the flow resistance is higher with respect to the increase in the parameters local temperature Grashof number, local nanoparticle Grashof number, Brownian motion parameter, and Prandtl number. It is pertinent to observe that increase in the Brownian motion parameter leads to increment in concentration and temperature profiles. It is observed that the concentration of nanoparticles decreases with increase in the value of thermophoresis parameter.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Akbar, N.S., 2015, Influence of magnetic field on peristaltic flow of a Casson fluid in an asymmetric channel: Application in crude oil refinement, J. Magn. Magn. Mater. 378, 463–468.

    Article  Google Scholar 

  • Akbar, N.S. and A.W. Butt, 2015, Magnetic field effects for copper suspended nanofluid venture through a composite stenosed arteries with permeable wall, J. Magn. Magn. Mater. 381, 285–291.

    Article  Google Scholar 

  • Bali, R. and U. Awasthi, 2012, A Casson fluid model for multiple stenosed artery in the presence of magnetic field, Appl. Math. 3, 436–441.

    Article  Google Scholar 

  • Beg, O.A., T.A. Beg, R. Bhargava, S. Rawat, and D. Tripathi, 2012, Finite element study of transient pulsatile magnetohemodynamic non-Newtonian flow and drug diffusion in a porous medium channel, J. Mech. Med. Biol. 12, 1250081.

    Article  Google Scholar 

  • Blair, G.W.S., 1959, An equation for the flow of blood, plasma and serum through glass capillaries, Nature 183, 613–614.

    Article  Google Scholar 

  • Blair, G.W.S. and D.C. Spanner, 1974, An Introduction to Biorheology, Elsevier Scientific, Amsterdam.

    Google Scholar 

  • Bloch, E.H., 1962, A quantitative study of the hemodynamics in the living microvascular system, Dev. Dyn. 110, 125–153.

    Google Scholar 

  • Caro, C.G., 1982, Arterial fluid mechanics and atherogenesis, Clin. Hemorheol. Microcirc. 2, 131–136.

    Article  Google Scholar 

  • Chakravarty, S. and P.K. Mandal, 2000, Two-dimensional blood flow through tapered arteries under stenotic conditions, Int. J. Non-Linear Mech. 35, 779–793.

    Article  Google Scholar 

  • Charm, S. and G. Kurland, 1965, Viscometry of human blood for shear rates of 0–100,000 sec−1, Nature 206, 617–618.

    Article  Google Scholar 

  • Chaturani, P. and R. Ponnalagarsamy, 1984, Analysis of pulsatile blood flow through stenosed arteries and its applications to cardiovascular diseases, Proceedings of the 13th National Conference on Fluid Mechanics and Fluid Power, Tiruchirapalli, India, 463–468.

    Google Scholar 

  • Chaturani, P. and R. Ponalagusamy, 1986, Pulsatile flow of Casson’s fluid through stenosed arteries with applications to blood flow, Biorheology 23, 499–511.

    Article  Google Scholar 

  • Chaturani, P. and V. Palanisamy, 1990, Casson fluid model for pulsatile flow of blood under periodic body acceleration, Biorheology 27, 619–630.

    Article  Google Scholar 

  • Choi, S.U.S. and J.A. Eastman, 1995,Enhancing thermal conductivity of fluids with nanoparticles, ASME International Mechanical Engineering Congress and Exposition, San Francisco, California, 44144.

    Google Scholar 

  • Dash, R.K., K.N. Mehta, and G. Jayaraman, 1996, Casson fluid flow in a pipe filled with a homogeneous porous medium, Int. J. Eng. Sci. 34, 1145–1156.

    Article  Google Scholar 

  • El-Shahed, M., 2003, Pulsatile flow of blood through a stenosed porous medium under periodic body acceleration, Appl. Math. Comput. 138, 479–488.

    Google Scholar 

  • Ellahi, R., 2013, The effects of MHD and temperature dependent viscosity on the flow of non-Newtonian nanofluid in a pipe: Analytical solutions, Appl. Math. Model. 37, 1451–1467.

    Article  Google Scholar 

  • Ellahi, R., M. Hassan, and A. Zeeshan, 2016, A study of heat transfer in power law nanofluid, Therm. Sci. 20, 2015–2026.

    Article  Google Scholar 

  • Ellahi, R., S.U. Rahman, S. Nadeem, and N.S. Akbar, 2014, Blood flow of nanofluid through an artery with composite stenosis and permeable walls, Appl. Nanosci. 4, 919–926.

    Article  Google Scholar 

  • Elshehawey, E.F., E.M.E. Elbarbary, N.A.S. Afifi, and M. El-Shahed, 2000, Pulsatile flow of blood through a porous mediumunder periodic body acceleration, Int. J. Theor. Phys. 39, 183–188.

    Article  Google Scholar 

  • Hariri, S., M. Mokhtari, M.B. Gerdroodbary, and K. Fallah, 2017, Numerical investigation of the heat transfer of a ferrofluid inside a tube in the presence of a non-uniform magnetic field, Eur. Phys. J. Plus 132, 65.

    Article  Google Scholar 

  • Hayat, T., R. Sajjad, A. Alsaedi, T. Muhammad, and R. Ellahi, 2017, On squeezed flow of couple stress nanofluid between two parallel plates, Results Phys. 7, 553–561.

    Article  Google Scholar 

  • Ibrahim, S.M., G. Lorenzini, P.V. Kumar, and C.S.K. Raju, 2017, Influence of chemical reaction and heat source on dissipative MHD mixed convection flow of a Casson nanofluid over a nonlinear permeable stretching sheet, Int. J. Heat Mass Transf. 111, 346–355.

    Article  Google Scholar 

  • Jeffords, J.V. and M.H. Knisley, 1956, Concerning the geometric shapes of arteries and arterioles: A contribution to the biophysics of health, disease, and death, Angiology, 7, 105–136.

    Article  Google Scholar 

  • Ku, D.N., 1997, Blood flow in arteries, Annu. Rev. Fluid Mech. 29, 399–434.

    Article  Google Scholar 

  • Liu, G.T., X.J. Wang, B.Q. Ai, and L.G. Liu, 2004, Numerical study of pulsating flow through a tapered artery with stenosis, Chin. J. Phys. 42, 401–409.

    Google Scholar 

  • Mamourian, M., K.M. Shirvan, and S. Mirzakhanlari, 2016, Two phase simulation and sensitivity analysis of effective parameters on turbulent combined heat transfer and pressure drop in a solar heat exchanger filled with nanofluid by response surface methodology, Energy 109, 49–61.

    Article  Google Scholar 

  • Mandal, P.K., 2005, An unsteady of non-Newtonian blood flow through tapered arteries with a stenosis, Int. J. Non-Linear Mech. 40, 151–164.

    Article  Google Scholar 

  • Mekheimer, K.S. and M.A. EI Kot, 2008, The micropolar fluid model for blood flow through a tapered artery with a stenosis, Acta Mech. Sin. 24, 637–644.

    Article  Google Scholar 

  • Merrill, E.W., A.M. Benis, E.R. Gilliland, T.K. Sherwood, and E.W. Salzman, 1965, Pressure-flow relations of human blood in hollow fibers at low flow rates, J. Appl. Physiol. 20, 954–967.

    Article  Google Scholar 

  • Nadeem, S. and S. Ijaz, 2015, Theoretical analysis of metallic nanoparticles on blood flow through stenosed artery with permeable walls, Phys. Lett. A 379, 542–554.

    Article  Google Scholar 

  • Nadeem, S., S. Ijaz, and M. Adil Sadiq, 2014, Inspiration of induced magnetic field on a blood flow of Prandtl nanofluid model with stenosis, Curr. Nanosci. 10, 753–765.

    Article  Google Scholar 

  • Nguyen, Q.D. and D.V. Boger, 1992, Measuring the flow properties of yield stress fluids, Annu. Rev. Fluid Mech. 24, 47–88.

    Article  Google Scholar 

  • Ponalagusamy, R., 1986, Blood Flow through Stenosed Tube, Ph.D Thesis, Indian Institute of Technology Bombay.

    Google Scholar 

  • Ponnalagarsamy, R. and M. Kawahara, 1989, A finite element analysis of laminar unsteady flow of viscoelastic fluids through channels with non-uniform cross-sections, Int. J. Numer. Methods Fluids 9, 1487–1501.

    Article  Google Scholar 

  • Ponalagusamy, R. and R. Tamil Selvi, 2013, Blood flow in stenosed arteries with radially variable viscosity, peripheral plasma layer thickness and magnetic field, Meccanica 48, 2427–2438.

    Article  Google Scholar 

  • Rahman, S.U., R. Ellahi, S. Nadeem, and Q.M. Zaigham Zia, 2016, Simultaneous effects of nanoparticles and slip on Jeffrey fluid through tapered artery with mild stenosis, J. Mol. Liq. 218, 484–493.

    Article  Google Scholar 

  • Rashidi, S., J.A. Esfahani, and R. Ellahi, 2017, Convective heat transfer and particle motion in an obstructed duct with two side by side obstacles by means of DPM model, Appl. Sci. 7, 431.

    Article  Google Scholar 

  • Rodkiewicz, C.M., P. Sinha, and J.S. Kennedy, 1990, On the application of a constitutive equation for whole human blood,J. Biomech. Eng.-Trans. ASME 112, 198–206.

    Article  Google Scholar 

  • Sharma, M.K., K. Bansal, and S. Bansal, 2012, Pulsatile unsteady flow of blood through porous medium in a stenotic artery under the influence of transverse magnetic field, Korea-Aust. Rheol. J. 24, 181–189.

    Article  Google Scholar 

  • Shaw, S., P.V.S.N. Murthy, and S.C. Pradhan, 2010, The effect of body acceleration on two dimensional flow of Casson fluid through an artery with asymmetric stenosis, Open Transport Phenom. J. 2, 55–68.

    Article  Google Scholar 

  • Shaw, S., R.S.R. Gorla, P.V.S.N. Murthy, and C.O. Ng, 2009, Pulsatile Casson fluid flow through a stenosed bifurcated artery, Int. J. Fluid Mech. Res. 36, 43–63.

    Article  Google Scholar 

  • Shehzad, N., A. Zeeshan, R. Ellahi, and K. Vafai, 2016, Convective heat transfer of nanofluid in a wavy channel: Buongiorno’s mathematical model, J. Mol. Liq. 222, 446–455.

    Article  Google Scholar 

  • Sheikholeslami, M., Q.M. Zaigham Zia, and R. Ellahi, 2016, Influence of induced magnetic field on free convection of nanofluid considering Koo-Kleinstreuer-Li (KKL) correlation, Appl. Sci. 6, 324.

    Article  Google Scholar 

  • Shukla, J.B., R.S. Parihar, and B.R.P. Rao, 1980, Effects of stenosis on non-Newtonian flow of the blood in an artery, Bull. Math. Biol. 42, 283–294.

    Article  Google Scholar 

  • Siddiqui, S.U., N.K. Verma, S. Mishra, and R.S. Gupta, 2009, Mathematical modelling of pulsatile flow of Casson’s fluid in arterial stenosis, Appl. Math. Comput. 210, 1–10.

    Google Scholar 

  • Young, D.F., 1968, Effect of a time-dependent stenosis on flow through a tube, J. Eng. Ind.-Trans. ASME 90, 248–254.

    Article  Google Scholar 

  • Young, D.F., 1979, Fluid mechanics of arterial stenoses, J. Biomech. Eng.-Trans. ASME 101, 157–175.

    Article  Google Scholar 

  • Young, D.F. and F.Y. Tsai, 1973, Flow characteristics in models of arterial stenoses - I. Steady flow, J. Biomech. 6, 395–402.

    Article  Google Scholar 

  • Zaman, A., N. Ali, and M. Sajid, 2017, Numerical simulation of pulsatile flow of blood in a porous-saturated overlapping stenosed artery, Math. Comput. Simul. 134, 1–16.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Ponalagusamy.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ponalagusamy, R., Priyadharshini, S. Numerical modelling on pulsatile flow of Casson nanofluid through an inclined artery with stenosis and tapering under the influence of magnetic field and periodic body acceleration. Korea-Aust. Rheol. J. 29, 303–316 (2017). https://doi.org/10.1007/s13367-017-0030-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13367-017-0030-2

Keywords

Navigation