Abstract
Two accurate, sensitive, precise and selective HPLC and stability-indicating TLC methods were developed for the simultaneous determination of camylofin-2HCl and paracetamol. Forced acid, alkali and oxidative degradation of camylofin-2HCl were tried where complete degradation was achieved using 5 N HCl. HPLC method was developed to determine the mixture of the two drugs using Zorbax NH2 column and a mobile phase of 0.5% triethylamine and pH 3.0 adjusted with 0.1% phosphoric acid and methanol (70:30 v/v) over concentration ranges of 3–90 and 10–95 µg/mL for camylofin-2HCl and paracetamol, respectively.TLC method was used for the separation of camylofin from its acid degradate and paracetamol using chloroform–methanol–acetone–conc. ammonia (8:2:2:0.1, by volume) as developing system and band scanning at 254 nm over concentration ranges of 5–40 µg/band for camylofin-2HCl and 0.1–0.5 µg/band for paracetamol. The validation of two methods was carried out according to ICH guideline. Accuracy ranged between 98.47 and 100.67% for the two methods with acceptable precision RSD% ranging between 0.66 and 1.47%.
Similar content being viewed by others
References
S.C. Sweetman, B. Pharm, F.R. Pharm, S. Martindale, The Complete Drug Reference, 39th edn. (The Pharmaceutical Press, London, 2017)
H.S. Warke, A.R. Chauhan, V.S. Raut, K.M. Ingle, Bombay Hosp. J. 45, 420–423 (2003)
S. Patel, P. Patil, H. Modi, R. Yadav, H. Baria, H. Anghan, Inventi. 13 (2013). http://inventi.in/journal/article/rapid/4/10455/pharm-analysis-quality-assurance/pi
B. Anupama, V. Ramakrishna, Int. J. Res. Pharm. Chem. 2, 1020–1022 (2012)
R.R. Singh, M.V. Rathnam, Pharm. Anal. Acta 1, 1–4 (2010)
A.M. Atta, M.S. Gomaa, I. Salama, S.M. Mostafa, IOSR J. Pharm. Biol. Sci. 11, 36–46 (2016). https://doi.org/10.9790/3008-1104043646
N.S. Patel, V.P. Gandh, R.S. Maheta, K.K. Bhatt, Der Pharm. Lett. 2, 193–207 (2010)
N.N. Kadam, P.C. Patil, R.R. Singh, Int. J. Pharm. Pharm. Sci. 3, 153–158 (2011)
R.R. Sing, V.M. Rathnam, J. Singh, K.R. Vegesna, ISRN Anal. Chem. (2012). https://doi.org/10.5402/2012/586415
S. Rathinam, K.S. Lakshmi, Int. J. Pharm. Pharm. Sci. 6, 585–589 (2014)
R.R. Singh, M.V. Rathnam, Am. J. Pharm. Technol. Res. 2, 448–457 (2012)
P.S. Barde, A.Y. Desai, S.M. Roy, V.V. Vaidya, ACAI J. 10, 207–210 (2011)
R.R. Singh, M.V. Rathnam, Anal. Chem. Indian J. 2, 321–331 (2012)
R.R. Singh, M.V. Rathnam, S.J. Singh, R.K. Vegesna, Am. J. Anal. Chem. 2, 944–952 (2011). https://doi.org/10.4236/ajac.2011.28110
A.M. Saeed, Int. J. Pharm. Sci. Rev. Res. 42, 53–57 (2017)
R. El-Bagary, E.F. El-Kady, A.A. Al-Matari, Asian. J. Pharm. Clin. Res. 10, 225–231 (2017). https://doi.org/10.22159/ajpcr.2017.v10i11.20491
M.K. Al-Shwaiyat, Jord. J Chem. 8, 79–89 (2013). https://doi.org/10.12816/0001519
M. Attimarad, Pharm. Method 2, 61–66 (2011). https://doi.org/10.4103/2229-4708.81084
M.I. Walash, F. Ibrahim, S. Abo El Abass, Anal. Lett. Chem. 7, 421–437 (2017). https://doi.org/10.1080/22297928.2017.1353921
S.P. Thomas, A. Poomali, Indian J. Pharm. Sci. 3, 169–172 (2016)
A.S. Lataifeha, F.A. Wedianb, Jord. J. Chem. 9, 217–227 (2014). https://doi.org/10.12816/0026402
U.K. Chhalotiya, D.B. Patel, D.A. Shah, F.A. Mehta, K.K. Bhatt, J. Pharm. Pharm. Sci. (2017). https://doi.org/10.29011/2574-7711/100011
D.J. Patel, V.P. Patel, Int. J. Chem. Tech. Res. 2, 1929–1932 (2010)
N.F. Farid, E.A. Abdelaleem, J. Chromatogr. Sci. 54, 647–652 (2016). https://doi.org/10.1093/chromsci/bmv184
A.A. Shirkhedkar, A.M. Shaikh, S.J. Surana, Eurasian J. Anal. Chem. 3, 258–267 (2008)
T. Belal, T. Awad, C.R. Clark, J. Chromatogr. Sci. 47, 849–854 (2009). https://doi.org/10.1093/chromsci/47.10.849
S. Stavchansky, H.B. Kostenbauder, Anal. Lett. 10, 1845–1856 (1977). https://doi.org/10.1080/00032717708067833
K. Hara, S. Kashimura, T. Yanai, M. Kashiwagi, A. Miyoshi, M. Kageura, Forensc. Toxicol. 24, 65–69 (2006). https://doi.org/10.1007/s11419-006-0014-2
A.W. Dechtlaruk, G.F. Johnson, H.M. Solomon, Clin. Chem. 22, 879–884 (1976)
L. Li, Y. Lu, Y. Ding, Y. Cheng, W. Xu, F. Zhang, J. Fluoresc. 22, 591–596 (2012). https://doi.org/10.1007/s10895-011-0994-0
A.B. Moreira, Anal. Chimica Acta 539, 257–261 (2005). https://doi.org/10.1016/j.aca.2005.03.012
J.I. Vilchez, R. Blanc, R. Avidad, A. Navaln, J. Pharm. Biomed. Anal. 13, 1119–1125 (1995). https://doi.org/10.1016/0731-7085(95)01537-U
E.M. Hussien, I.A. Mohammed, S.A. Abd El-Razeq, Int. Res. J. Pure Appl. Chem. 17, 1–12 (2019). https://doi.org/10.9734/IRJPAC/2018/45823
A. Naeemya, R. Gholam-Shahbazi, A. Mohammadia, J. Electrochem. Sci. Technol. 8, 282–293 (2017). https://doi.org/10.5229/JECST.2017.8.4.282
R.M. Goyal, S.P. Singh, Electrochim. Acta 51, 2008–3012 (2006). https://doi.org/10.1016/j.electacta.2005.08.036
R.M.A. Tehrania, H. Ghadimib, Anal. Bioanal. Chem. Res. 3, 111–121 (2016). https://doi.org/10.22036/abcr.2016.14839
S. Makwana, M. Patel, D. Prajapati, C. Shingala, J. Upadhyay, A. Shah, Res. Int. (2016). https://doi.org/10.1155/2016/1596021
R.R. Singh, M.V. Rathnam, R. Vegesna, Ind. J. Anal. Chem. 7, 1–4 (2008)
H. Patel, B. Kotadiya, P. Patel, Inventi. 14 (2014). http://inventi.in/journal/article/rapid/4/10967/pharm-analysis-quality-assurance/pi
The United States Pharmacopeia 32, NF 27, Asian Ed., Rand Mc Nally, USA, p. 235 (2010)
B. Fried, J. Sherma, Thin Layer Chromatography, 4th edn. (Marcel Dekker Inc., New York, USA, 1999)
ICH Validation of analytical procedures: text and methodology Q2 (R1), in International Conference on Harmonization (2005)
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors declare no conflict of interest.
Rights and permissions
About this article
Cite this article
Abdel Razeq, S.A., Khalil, I.A. & Mohammd, S.A. Validated HPLC and stability-indicating densitometric chromatographic methods for simultaneous determination of camylofin dihydrochloride and paracetamol in their binary mixture. J IRAN CHEM SOC 17, 2587–2597 (2020). https://doi.org/10.1007/s13738-020-01953-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13738-020-01953-8