Skip to main content

The Dynamic Hip Screw Implant System

  • Book
  • © 1985

Overview

This is a preview of subscription content, log in via an institution to check access.

Access this book

eBook USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Other ways to access

Licence this eBook for your library

Institutional subscriptions

Table of contents (8 chapters)

Keywords

About this book

The AOjASIF* dynamic hip screw (DRS) has been designed primarily to stabilize trochanteric fractures of the hip. Selected fractures of the femoral neck and some subtrochanteric fractures are further indications for the DRS [40, 46]. The dynam­ ic condylar screw (DCS) has been developed for fractures of the distal femur and is now being tested clinically. The DRS and DCS are carefully coordinated with the preexisting ASIF standard sets of equipment for internal fixation of fractures. The concept of a sliding screw for trochanteric fractures is not new. The first author describing such an implant was Schumpelick [44]; he gives credit to Pohl [22], who was primarily a manufacturer working for Gerhardt Kiinscher. Re described the possibility of impaction at the fracture site with a sliding device. In the United States Clawson [7, 8] introduced the hip screw and found it to be extremely beneficial in trochanteric fractures. At approximately the same time, Massie [31, 32] and Pugh [39] designed the sliding-type flange nails, which offer similar intramedullary splinting with the possibility of fracture impaction. The following chapters describe the concept and design features of the DRS, as well as the details of the surgical technique. The application of the DRS for different types of fractures is illustrated with clinical examples. The results of 268 cases of trochanteric fractures treated with the DRS are presented and compared with results using the angled blade plate and Ender's nails. Finally, some laboratory tests are described.

Authors and Affiliations

  • Departement Chirurgie der Universität, Basel, Switzerland

    Pietro Regazzoni

  • Departement Chirurgie, Rätisches Kantonsspital Chur, Chur, Switzerland

    Thomas Rüedi

  • Orthopedic Physicians, Inc., P.S., Seattle, USA

    Robert Winquist

  • Basel, Switzerland

    Martin Allgöwer

Bibliographic Information

  • Book Title: The Dynamic Hip Screw Implant System

  • Authors: Pietro Regazzoni, Thomas Rüedi, Robert Winquist, Martin Allgöwer

  • DOI: https://doi.org/10.1007/978-3-642-69925-2

  • Publisher: Springer Berlin, Heidelberg

  • eBook Packages: Springer Book Archive

  • Copyright Information: Springer-Verlag Berlin Heidelberg 1985

  • Softcover ISBN: 978-3-642-69927-6Published: 19 November 2011

  • eBook ISBN: 978-3-642-69925-2Published: 06 December 2012

  • Edition Number: 1

  • Number of Pages: V, 51

  • Number of Illustrations: 32 b/w illustrations

  • Topics: Surgical Orthopedics, Traumatic Surgery

Publish with us