Skip to main content
Log in

Cracking During Nanoindentation and its Use in the Measurement of Fracture Toughness

  • Published:
MRS Online Proceedings Library Aims and scope

Abstract

Results of an investigation aimed at developing a technique by which the fracture toughness of a thin film or small volume can be determined in nanoindentation experiments are reported. The method is based on the radial cracking which occurs when brittle materials are deformed by a sharp indenter such as a Vickers or Berkovich diamond. In microindentation experiments, the lengths of radial cracks have been found to correlate reasonably well with fracture toughness, and a simple semi-empirical method has been developed to compute the toughness from the crack lengths. However, a problem is encountered in extending this method into the nanoindentation regime with the standard Berkovich indenter in that there are well defined loads, called cracking thresholds, below which indentation cracking does not occur in most brittle materials. We have recently found that the problems imposed by the cracking threshold can be largely overcome by using an indenter with the geometry of the corner of a cube. For the cube-corner indenter, cracking thresholds in most brittle materials are as small as 1 mN (∼ 0.1 grams). In addition, the simple, well-developed relationship between toughness and crack length used for the Vickers indenter in the microindentation regime can be used for the cube-corner indenter in the nanoindentation regime provided a different empirical constant is used.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. G.M. Pharr and W.C. Oliver, MRS Bulletin 17, 28 (1992).

    Article  Google Scholar 

  2. W.C. Oliver, MRS Bulletin 11, 15 (1986).

    Article  Google Scholar 

  3. M.F. Doerner and W.D. Nix, J. Mater. Res. 1, 601 (1986).

    Article  Google Scholar 

  4. W.C. Oliver and G.M. Pharr, J. Mater. Res. 7, 1564 (1992).

    Article  CAS  Google Scholar 

  5. M.J. Mayo and W.D. Nix, Acta Metall. 36, 2183 (1988).

    Article  CAS  Google Scholar 

  6. B.R. Lawn, A.G. Evans, and D.B. Marshall, J. Am. Ceram. Soc. 63, 574 (1980).

    Article  CAS  Google Scholar 

  7. G.R. Anstis, P. Chantikul, B.R. Lawn, and D.B. Marshall, J. Am. Ceram Soc. 64, 533 (1981)

    Article  CAS  Google Scholar 

  8. J. Lankford, and D.L. Davidson, J. Mater. Sci. 14, 1662 (1979).

    Article  CAS  Google Scholar 

  9. K. Hirao and M. Tomozawa, J. Am. Ceram. Soc. 70, 497 (1987).

    Article  CAS  Google Scholar 

  10. A. Arora, D.B. Marshall, B.R. Lawn, and M.V. Swain, J. Non-Cryst. Sol. 31, 415 (1979).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Harding, D.S., Oliver, W.C. & Pharr, G.M. Cracking During Nanoindentation and its Use in the Measurement of Fracture Toughness. MRS Online Proceedings Library 356, 663–668 (1994). https://doi.org/10.1557/PROC-356-663

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1557/PROC-356-663