Abstract
An implantable variable resistance pressure gauge has been constructed from a conductive elastomere in the form of a scleral buckle which is suitable for recording intraocular pressure in vivo continuously over an indefinite period of time. The similarity of the pressure transducer to the standard scleral buckles used to reduce retinal detachments suggests that it will be tolerated over a period of years without significant effect on intraocular pressure. The electrical output from these pressure gauges appears to be both well defined and of sufficient magnitude to operate a valve to control intraocular pressure.
Similar content being viewed by others
References
Caudell, T.P., F.M. Smolka, D.R. Eisenstein & B.L. Eisenstein. Silicone rubber applied within the eye; a preliminary study. Appl. Opt. 18: 1305–1310 (1979).
Collins, G.C. Miniature passive pressure transensor for implanting in the eye. IEEE Trans. Biomed. Eng. 14: 34 (1963).
Cooper, R.L. & D. Beale. Radio telemetry of intraocular pressure in vitro. Invest. Ophthalmol. Vis. Sci. 16: 168–171 (1977).
Couvillon, L.A., C.D. Baker & T.P. Grover. Intraocular pressure new non-invasive, continuous monitoring system. Trans. 28th American Conference on Engineering in Medicine and Biology (ACEMB). New Orleans, p. 324, Sept. 22–24 (1975).
de Venicia, G. & M.D. Davis. Diurnal variation of intraocular pressure in the normal eye. Arch. Ophthalmol. 69: 752 (1963).
Drance, S.M. The significance of the diurnal tension variations in normal and glaucoma eyes. Arch. Ophthalmol. 64: 494 (1960).
Greene, M.E. & B.G. Gilman. Intraocular pressure measurement with instrumented contact lenses. Invest. Ophthalmol. 13: 229–302 (1974).
Matsumo, T., R. Nagata, M. Slashin, T. Matsuda, & S. Nakao. Measurement by holographic interferometry of the deformation of the eye accompanying changes in intraocular pressure. Appl. Opt. 17: 3538–3539 (1978).
Phelps, C.D., R.F. Woolson, A.E. Kolker & B. Becker. Diurnal variations in intraocular pressure. Amer. J. Ophthalmol. 77: 367–377 (1974).
Schepens, C.L. Scleral buckling with circling element. Trans. Amer. Acad. Ophthalmol. Otolaryngol. 68: 959–979 (1964).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wolbarsht, M.L., Wortman, J., Schwartz, B. et al. A scleral buckle pressure gauge for continuous monitoring of intraocular pressure. Int Ophthalmol 3, 11–17 (1980). https://doi.org/10.1007/BF00136208