Skip to main content
Log in

3D MR imaging with Gd-DTPA in head and neck lesions

  • Original Articles
  • Head and Neck Radiology
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

Three-dimensional MR imaging technique is not a new concept, however, there is very little experience concerning clinical trials. Especially in head and neck lesions, the accuracu of this new imaging method has not yet been tested. A pilot study was performed to evaluate the diagnostic value of demonstrating the head and neck lesions and topographical structures implemented in a three-dimensional reconstruction of the entire head. The 3D reconstruction mode is based on the ray-tracting model. The application of the contrast medium Gd-DTPA proved to be helpful. Three-dimensional reconstruction revealed clear topographic details of the lesions, including the spread of infiltration and destruction of soft tissue. Additionally, the simultaneous view of multiple slices in different orientations is an ideal method for evalauting the spread of the lesion and to visualize the relation between lesion and surrounding tissue.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Glenn W. V., Johnson R. J., Morton P. E., Dwyer S. J. (1975) Image generation and display techniques for CT scan data. Invest Radiol. 10: 403–416

    Google Scholar 

  2. Herman G. T., Liu H. K. (1977) Display of three-dimensional information in computed tomography. J Comput Assit Tomogr 1: 155–160

    Google Scholar 

  3. Carlson J., Crooks L., Ortendahl D., Kramer D. M., Kaufman L. (1988) Signal-to-noise ratio and section thickness in two-dimensional versus three-dimensional Fourier transform MR imaging. Radiology 166: 266–270

    Google Scholar 

  4. Frahm J., Haase A., Matthaei D. (1986) Rapid three-dimensional MR imaging using the FLASH technique. J Comput Assist Tomogr 10: 363–368

    Google Scholar 

  5. Hoehne k. H., Delapaz R. L., Bernstein R., Taylor R. C. (1987) Combined surface display and reformatting for the three-dimensional analysis of tomographic data. Invest Radiol 22: 658–664

    Google Scholar 

  6. Harms S. E., Muschler G (1986) Three-dimensional MR imaging of the knee using surface coils. J Comput Assist Tomogr 10: 773–777

    Google Scholar 

  7. Skalej M., Klose U., Kuper K. (1988) Optimized examination technique of meniscopathy bi 1.5T MR 3D imaging. RÖFO 148: 183–188

    Google Scholar 

  8. Tyrrell R. L., Gluckert K., Pathria M., Modic M. T. (1988) Fast three-dimensional MR imaging of the knee: comparison with arthroscopy. Radiology 166: 865–872

    Google Scholar 

  9. Cline H. E., Dumoulin C. L., Hart H. R., Lorensen W. E., Ludke S. (1987) 3D reconstruction of the brain from magnetic resonance images using a connectivity algorithm. Magn Reson Imaging 5: 345–352

    Google Scholar 

  10. Herman G. T. (1988) Three-dimensional imaging on a CT or MR scanner. J Comput Assist Tomogr 12: 450–458

    Google Scholar 

  11. Marsh J. L., Vannier M. W. (1983) The “third” dimension in craniofacial surgery. Plast Reconstr Surg 71: 759–767

    Google Scholar 

  12. Zonneveld F. W., van der Meulen J. C., van Akkerveeken P. F., Koornneef L., Vaandrager J. M., van der Horst C. M. (1988) Three-dimensional imaging of CT-data and clinical applications in orthopedics and surgery of the bones of the face. Röntgen-strahlen 59: 28–29

    Google Scholar 

  13. Cline H. E., Lorensen W. E., Herfkens R. J., Johnson G. A., Glover G. H. (1989) Vascular morphology by three-dimensional magnetic resonance imaging. Magn Reson Imaging 7: 45–54

    Google Scholar 

  14. Kashiwagi T., Mitsutani N., Koizumi T., Kimura K (1988) Three-dimensional demonstration of liver and spleen by a computer graphics technique. Acta Radiol 29: 27–31

    Google Scholar 

  15. Kett H., Obletter N., Breit A. (1987) Development of the MR-diagnostic: combination of 3D sequences with fast image systems. RÖFO 147: 557–562

    Google Scholar 

  16. Sherry C. S., Harms S. E., Mc Croskey W. K. (1987) Spinal MR imaging: multiplanar representation from a single high resolution 3D acquisition. J Comput Assist Tomogr 11: 859–862

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Offprint request to: T. Vogl

Rights and permissions

Reprints and permissions

About this article

Cite this article

Vogl, T., Wilimzig, C., Assal, J. et al. 3D MR imaging with Gd-DTPA in head and neck lesions. Eur. Radiol. 1, 151–157 (1991). https://doi.org/10.1007/BF00451299

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00451299

Key words

Navigation