Skip to main content
Log in

An analysis of portal vein spontaneous contractions

  • Published:
Pflügers Archiv Aims and scope Submit manuscript

Summary

Spontaneous tension changes of isolated strips of guinea-pig portal vein were analysed using the time series analysis (evaluation of autocorrelation function and power spectra). The results indicated three typical power spectral maxima with frequencies of 0.01–0.03 Hz, 0.05–0.08 Hz and 0.09–0.2 Hz. These vascular smooth muscle oscillation components were compared with the vascular autooscillations of the isolated rat kidney and with the mechanical oscillations of the taenia coli which had been previously determined.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Başar, E., Eroĝlu, C., Ungan, P.: Time series analysis of guinea-pig taenia coli spontaneous activity. Pflügers Arch.347, 19–25 (1974)

    Google Scholar 

  • Başar, E., Ruedas, G., Schwarzkopf, H., Weiss, Ch.: Untersuchungen des zeitlichen Verhaltens druckabhängiger Änderungen des Strömungswiderstandes im Coronargefäßsystem des Rattenherzens. Pflügers Arch.304, 189–202 (1968)

    Google Scholar 

  • Başar, E., Weiss, Ch.: Analyse des Frequenzganges druckinduzierter Änderungen des Strömungswiderstandes isolierter Rattennieren. Pflügers Arch.304, 121–135 (1968)

    Google Scholar 

  • Başar, E., Weiss, Ch.: Time series analysis of spontaneous fluctuations of the flow in the perfused rat kidney. Pflügers Arch.319, 205–214 (1970)

    Google Scholar 

  • Bendat, J. S., Piersol, A. G.: Measurement and analysis of random data. New York: John Miley and Sons, Inc. 1967

    Google Scholar 

  • Funaki, S., Bohr, D.: Electrical and mechanical activity of isolated vascular smooth muscle of the rat. Nature (Lond.)203, 192–194 (1964)

    Google Scholar 

  • Gebert, G., Konold, P., Seboldt, H.: Eigenschaften und Beeinflußbarkeit der mechanischen Spontanaktivität isolierter Arterien. Pflügers Arch. ges. Physiol.299, 285–294 (1968)

    Google Scholar 

  • Golenhofen, K.: Slow rhythms in smooth muscle (Minute-Rhythm). In: E. Bülbring (Ed.): Smooth muscle. London: Arnold Ltd. 1970

    Google Scholar 

  • Golenhofen, K., Loh, D. V.: Intracellulare Potentialmessungen zur normalen Spontanaktivität der isolierten Portal Vene des Meerschweinchens. Pflügers Arch.319, 82–100 (1970)

    Google Scholar 

  • Holman, M. E., Kasby, C. B., Suthers, M. B., Wilson, J. A. F.: Some properties of the smooth muscle of rabbit portal vein. J. Physiol. (Lond.)196, 111–132 (1968)

    Google Scholar 

  • Johansson, B., Ljung, B. L.: Sympathetic control of rhythmically active vascular smooth muscle as studied by a nerve-muscle preparation of portal vein. Acta physiol. scand.70, 299–311 (1967)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This work was supported by Grant-TAG 229 of Scientific and Technical Research Council of Turkey (T.B.T.A.K.).

Varian, A. G. (Switzerland) supported this work with additional memory supply to our computer and with steady technical assistance.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Başar, E., Eroglu, C. & Ungan, P. An analysis of portal vein spontaneous contractions. Pflugers Arch. 352, 135–143 (1974). https://doi.org/10.1007/BF00587512

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00587512

Key words

Navigation