Skip to main content
Log in

Cardiovascular and electrocardiographic effects of iopentol in left ventricular angiography Comparison of the low-osmolar, non-ionic iopentol (Imagopaque® 350) and the hyper-osmolar, ionic metrizoate meglumine-Na-Ca (Isopaque® Coronar 370) in patients with coronary heart disease

Comparison of the low-osmolar, non-ionic iopentol (Imagopaque® 350) and the hyper-osmolar, ionic metrizoate meglumine-Na-Ca (Isopaque® Coronar 370) in patients with coronary heart disease

  • Published:
European Radiology Aims and scope Submit manuscript

Abstract.

The aim of the study was to evaluate and compare the hemodynamic and electrocardiographic effects following injection of the non-ionic, low- osmolar contrast medium iopentol (Imagopaque® 350, Nycomed Imaging AS, Oslo, Norway) and the ionic, hyper-osmolar contrast medium metrizoate meglumine-Na-Ca (Isopaque® Coronar 370, Nycomed Imaging AS, Oslo, Norway) when used for left ventricular angiography. The study was performed in a double-blind, randomized manner in 82 patients with severe coronary heart disease. The patients who received iopentol experienced less adverse events and subjective discomfort of lesser intensity than those who received metrizoate (p = 0.0001). Both contrast media induced a biphasic change in left ventricular (LV) systolic pressure, with an initial fall followed by a prolonged rise, but the alterations were statistically significantly more pronounced with metrizoate than with iopentol. The changes in LV end-diastolic pressure (p = 0.023), and LV negative dP/dt (p = 0.002) were significantly more pronounced with metrizoate than with iopentol. Cardiac output and heart rate increased more with metrizoate, while stroke volume was equally increased by both agents. A prolonged increase in the QT-interval, throughout the 10-min observation period, was seen only after injection of metrizoate (p = 0.0006 for comparison between contrast media). Conclusion: Iopentol was well tolerated and induced markedly less severe hemodynamic and electrocardiographic alterations than did metrizoate in patients with severe coronary heart disease.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Vik-Mo, H., Danielsen, R., Skinningsrud, K. et al. Cardiovascular and electrocardiographic effects of iopentol in left ventricular angiography Comparison of the low-osmolar, non-ionic iopentol (Imagopaque® 350) and the hyper-osmolar, ionic metrizoate meglumine-Na-Ca (Isopaque® Coronar 370) in patients with coronary heart disease. Eur Radiol 7 (Suppl 4), S156–S161 (1997). https://doi.org/10.1007/PL00006885

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/PL00006885

Navigation