Abstract
Objective
Incidence of primary mechanical complications and malpositions associated with landmark-guided central venous access procedures (CVAP) performed by experienced operators.
Design
Prospective 5-year observational study on two intensive care units.
Intervention
Only CVAPs using Seldinger technique were evaluated. Age, gender, puncture site, number of cannulation attempts, and complications within 24 hours and malpositions were recorded.
Patients
782 CVAPs in females aged 9–92 yrs and 1012 CVAPs in males aged 6–89 yrs.
Results
We analyzed 1794 (1017 right- and 777 left-sided CVAP), of which 87.7% were accomplished without adverse events. More than one cannulation attempt was a risk factor for failed catheterization, other mechanical complications but not for malposition. Complications/malpositions were encountered in 220 CVAPs.In 51 CVAPs (2.8%) the cannulation failed at the attempted site, here 18 CVAPs were accompanied by further complications (35.3%). Otherwise, the rate for mechanical complications was low (3.3%). The most common mechanical complications (n = 127) were arterial punctures (n = 52; 2.9%), including four arterial cannulations (0.2%), and pneumothorax (n = 9; 0.6%). There was significant risk for arterial puncture with the internal jugular vein approach in comparison to the innominate vein (p = 0.004), but not to the subclavian vein (p = 0.065). Male patients had a lower risk for failure (2.1%) than females (3.8%, p = 0.028). One-hundred-twenty-one central venous catheters were malpositioned (6.7%) of which 35 were related to the left internal jugular vein.
Conclusions
Even experienced operators cause a considerable number of early mechanical complications and malpositions. After two unsuccessful cannulation attempts failure and associated complications are very likely.
References
Schummer W, Schummer C, Tuppatsch H, Reinhart K, Huttemann E (2004) On the use of ultrasound to assist central vein cannulation in Germany: a survey of 817 departments of anesthesia. Anasthesiol Intensivmed Notfallmed Schmerzther 39:87–93
McGee DC, Gould MK (2003) Preventing complications of central venous catheterization. N Engl J Med 348:1123–1133
Sznajder JI, Zveibil FR, Bitterman H, Weiner P, Bursztein S (1986) Central vein catheterization. Failure and complication rates by three percutaneous approaches. Arch Intern Med 146:259–261
Lefrant JY, Muller L, De La Coussaye JE, Prudhomme M, Ripart J, Gouzes C, Peray P, Saissi G, Eledjam JJ (2002) Risk factors of failure and immediate complication of subclavian vein catheterization in critically ill patients. Intensive Care Med 28:1036–1041
Hatfield A, Bodenham A (1999) Portable ultrasound for difficult central venous access. Br J Anaesth 82:822–826
Denys BG, Uretsky BF (1991) Anatomical variations of internal jugular vein location: impact on central venous access. Crit Care Med 19:1516–1519
Rüsch S, Walder B, Tramer MR (2002) Complications of central venous catheters: internal jugular versus subclavian access – a systematic review. Crit Care Med 30:454–460
Hubler M, Litz RJ, Meier VK, Albrecht DM (2002) Innominate veins for central venous access: comment on “Central venous catheter use. I. Mechanical complications” by Polderman and Girbes. Intensive Care Med 28:805
Schummer W, Schummer C, Niesen WD, Gerstenberg H (2003) Doppler-guided cannulation of internal jugular vein, subclavian vein and innominate (brachiocephalic) vein – a case–control comparison in patients with reduced and normal intracranial compliance. Intensive Care Med 29:1535–1540
Augoustides JG, Diaz D, Weiner J, Clarke C, Jobes DR (2002) Current practice of internal jugular venous cannulation in a university anesthesia department: influence of operator experience on success of cannulation and arterial injury. J Cardiothorac Vasc Anesth 16:567–571
Mukau L, Talamini MA, Sitzmann JV (1991) Risk factors for central venous catheter-related vascular erosions. J Parenter Enteral Nutr 15:513–516
Robinson JF, Robinson WA, Cohn A, Garg K, Armstrong JD, 2nd (1995) Perforation of the great vessels during central venous line placement. Arch Intern Med 155:1225–1228
Shah KB, Rao TL, Laughlin S, El-Etr AA (1984) A review of pulmonary artery catheterization in 6,245 patients. Anesthesiology 61:271–275
Polderman KH, Girbes AJ (2002) Central venous catheter use. 1. Mechanical complications. Intensive Care Med 28:1–17
Mansfield PF, Hohn DC, Fornage BD, Gregurich MA, Ota DM (1994) Complications and failures of subclavian-vein catheterization. N Engl J Med 331:1735–1738
Muhm M (2002) Ultrasound guided central venous access. BMJ 325:1373–1374
Bodenham AR (2006) Can you justify not using ultrasound guidance for central venous access? Crit Care 10:175
Schummer W, Schummer C, Schelenz C, Schmidt P, Frober R, Huttemann E (2005) Modified ECG-guidance for optimal central venous catheter tip positioning. A transesophageal echocardiography controlled study. Anaesthesist 54:983–990
Bjarnason H, Lehman S (1997) Central venous access. In: Castaneda-Zuniga WR, Tadavarthy SM (eds) Interventional Radiology – methods. Williams & Wilkins, Baltimore, pp 941–965
Schuster M, Nave H, Piepenbrock S, Pabst R, Panning B (2000) The carina as a landmark in central venous catheter placement. Br J Anaesth 85:192–194
Muhm M, Sunder-Plassmann G, Apsner R, Pernerstorfer T, Rajek A, Lassnigg A, Prokesch R, Derfler K, Druml W (1997) Malposition of central venous catheters. Incidence, management and preventive practices. Wien Klin Wochenschr 109:400–405
Author information
Authors and Affiliations
Corresponding author
Additional information
The study was performed at the Clinic for Neurology, University Hospital Hamburg-Eppendorf, and the Clinic for Anesthesiology and Intensive Care Medicine, Friedrich-Schiller University of Jena, both Germany
There are no possible conflicts of interest, sources of financial support, corporate involvement, patent holdings, etc. for any of the authors
Electronic supplementary material
Rights and permissions
About this article
Cite this article
Schummer, W., Schummer, C., Rose, N. et al. Mechanical complications and malpositions of central venous cannulations by experienced operators. Intensive Care Med 33, 1055–1059 (2007). https://doi.org/10.1007/s00134-007-0560-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00134-007-0560-z