Abstract
An algorithm is proposed for extracting relevant information from near-infrared (NIR) spectra for multivariate calibration of routine components in complex plant samples. The algorithm is a combination of wavelet transform (WT) data compression and a procedure for uninformative variable elimination (UVE). After compression of the NIR spectra by WT, the UVE approach is used to eliminate the irrelevant wavelet coefficients. Finally, a calibration model is built from the retained wavelet coefficients to enable prediction. Because irrelevant information can be removed from the spectra used for multivariate calibration, the model based on the extracted relevant features is better than those obtained with full-spectrum data. Both prediction precision and calculation speed are improved.
Similar content being viewed by others
References
Ratcliffe M, Panozzo JF (1999) J Inst Brew 105:85
Bruno-Soares AM, Murray I, Paterson RM, Abreu JMF (1998) Animal Feed Sci Technol 75:15
Borjesson T, Stenberg B, Linden B, Jonsson A (1999) Plant and Soil 214:75
Blanco M, Coello J, Iturriaga H, Maspoch S, Pages (2000) Chemom Intell Lab Syst 50:75
Hoskuldsson A (2001) Chemom Intell Lab Syst 55:23
Trygg J, Wold S (1998) Chemom Intell Lab Syst 42:209
Shao XG, Cai WS (1998) Rev Anal Chem 17:235
Jouan-Rimbaud D, Walczak B, Poppi RJ, deNoord OE, Massart DL (1997) Anal Chem 69:4317
Alsberg BK, Woodward AM, Winson MK, Rowland JJ, Kell DB (1998) Anal Chim Acta 368:29
Centner V, Massart DL, deNoord OE, deJong S, Vandeginste BM, Sterna C (1996) Anal Chem 68:3851
Pasti L, Jouan-Rimbaud D, Massart DL, deNoord OE (1998) Anal Chim Acta 364:253
Galvao RKH, Pimentel MF, Araujo MCU, Yoneyama T, Visani V (2001) Anal Chim Acta 443:107
Eklov T, Martensson P, Lundstrom I (1999) Anal Chim Acta 381:221
Araujo MCU, Saldanha TCB, Galvao RKH, Yoneyama T, Chame HC, Visani V (2001) Chemom Intell Lab Syst 57:65
Lindgren F, Geladi P, Berglund A, Sjostrom M, Wold S (1995) J Chemom 9:331
Walczak B, Massart DL (1997) Chemom Intell Lab Syst 36:81
Leung AKM, Chau FT, Gao JB, Shih TM (1998) Chemom Intell Lab Syst 43:69
Acknowledgement
This study is supported by the National Natural Science Foundation of China (No. 29975027) and State Tobacco Monopoly Administration Bureau of China (No. 110200101042)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Shao, X., Wang, F., Chen, D. et al. A method for near-infrared spectral calibration of complex plant samples with wavelet transform and elimination of uninformative variables. Anal Bioanal Chem 378, 1382–1387 (2004). https://doi.org/10.1007/s00216-003-2397-9
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-003-2397-9