Abstract
Patients intended for circulatory support by cardiac assist devices (CAD) usually suffer from end-stage acute or chronic heart failure. Since the introduction of CAD in 1963 by DeBakey and coworkers, the systems have gone through a substantial evolution and have been increasingly used in the intervening decades. The spectrum of CAD includes a variety of systems serving to assist the systolic function of the left ventricle, the right ventricle, or both. Conventional radiography and multislice spiral computed tomography (CT) are the most commonly used radiological techniques for imaging patients with a CAD. CT is very useful for evaluating CAD systems by using both two- and three-dimensional reconstructions of the volumetric data sets. The two techniques together allow for the comprehensive assessment of patients with devices by imaging the in- and outflow cannulae, the anastomoses, the position of the pump, as well as associated complications. A close collaboration with cardiac surgeons with expertise in the field of circulatory support is deemed necessary for adequate image interpretation. This article describes the technical diversity of the currently available CAD systems. The imaging characteristics on conventional radiography and multislice spiral CT as well as the typical complications of their use are demonstrated.
Similar content being viewed by others
References
Mendez GF, Cowie MR (2001) The epidemiological features of heart failure in developing countries: a review of the literature. Int J Cardiol 80:213–219
Hunt SA, Baker DW, Chin MH et al (2002) ACC/AHA guidelines for the evaluation and management of chronic heart failure in the adult: executive summary. J Heart Lung Transplant 21:189–203
Hetzer R, Jurmann MJ, Potapov EV et al (2002) Heart assist systems—current status. Herz 27:407–417
Gray NA Jr, Selzman CH (2006) Current status of the total artificial heart. Am Heart J 152:4–10
Hall CW, Liotta D, Henly WS, Crawford ES, Debakery ME (1964) Development of artificial intrathoracic circulatory pumps. Am J Surg 108:685–692
Frazier OH, Rose EA, Oz MC et al (2001) Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. J Thorac Cardiovasc Surg 122:1186–1195
DeBakey ME (1971) Left ventricular bypass pump for cardiac assistance. Clinical experience. Am J Cardiol 27:3–11
Drews T, Loebe M, Jurmann M, zu Dohna R, Erben M, Hetzer R (2001) Outpatients on biventricular assist devices. Thorac Cardiovasc Surg 49:296–299
Frazier OH, Jacob LP (2007) Small pumps for ventricular assistance: progress in mechanical circulatory support. Cardiol Clin 25:553–564, vi
Frazier OH, Delgado RM (2003) Mechanical circulatory support for advanced heart failure: where does it stand in 2003? Circulation 108:3064–3068
Jain VR, White CS, Pierson RN 3rd, Griffith BP, Sorensen EN (2005) Imaging of left ventricular assist devices. J Thorac Imaging 20:32–40
Stone ME (2007) Current status of mechanical circulatory assistance. Semin Cardiothorac Vasc Anesth 11:185–204
Cascade PN, Meaney JF, Jamadar DA (1997) Methods of cardiopulmonary support: a review for radiologists. Radiographics 17:1141–1155
Lietz K, Miller LW (2004) Left ventricular assist devices: evolving devices and indications for use in ischemic heart disease. Curr Opin Cardiol 19:613–618
Song X, Throckmorton AL, Untaroiu A et al (2003) Axial flow blood pumps. Asaio J 49:355–364
Yacoub MH, Miller LW (2008) Long-term left-ventricular-assist-device therapy is here to stay. Nat Clin Pract Cardiovasc Med 5:60–61
Helman DN, Addonizio LJ, Morales DL et al (2000) Implantable left ventricular assist devices can successfully bridge adolescent patients to transplant. J Heart Lung Transplant 19:121–126
Birks EJ, Tansley PD, Yacoub MH et al (2004) Incidence and clinical management of life-threatening left ventricular assist device failure. J Heart Lung Transplant 23:964–969
Allen GS, Murray KD, Olsen DB (1997) The importance of pulsatile and nonpulsatile flow in the design of blood pumps. Artif Organs 21:922–928
Schmid C, Jurmann M, Birnbaum D et al (2008) Influence of inflow cannula length in axial-flow pumps on neurologic adverse event rate: results from a multi-center analysis. J Heart Lung Transplant 27:253–260
Wilhelm MJ, Hammel D, Schmid C et al (2005) Long-term support of 9 patients with the DeBakey VAD for more than 200 days. J Thorac Cardiovasc Surg 130:1122–1129
Cooper DS, Jacobs JP, Moore L et al (2007) Cardiac extracorporeal life support: state of the art in 2007. Cardiol Young 17(Suppl 2):104–115
Gandhi SK (2009) Ventricular assist device in children. Prog Pediatr cardiol 26:11–99
Aaronson KD, Patel H, Pagani FD (2003) Patient selection for left ventricular assist device therapy. Ann Thorac Surg 75:S29–S35
Bean MJ, Pannu H, Fishman EK (2005) Three-dimensional computed tomographic imaging of complex congenital cardiovascular abnormalities. J Comput Assist Tomogr 29:721–724
Leschka S, Oechslin E, Husmann L et al (2007) Pre- and postoperative evaluation of congenital heart disease in children and adults with 64-section CT. Radiographics 27:829–846
Knisely BL, Collins J, Jahania SA, Kuhlman JE (1997) Imaging of ventricular assist devices and their complications. AJR Am J Roentgenol 169:385–391
Knollmann FD, Loebe M, Weng Y et al (1999) Radiologic anatomy of ventricular assist devices. J Thorac Imaging 14:293–299
Knollman FD, Halfmann R, Regn J et al (1999) Motion artifacts in cardiac CT. The Novacor left ventricular assist device and its implications for clinical imaging. Acta Radiol 40:569–577
Kavarana MN, Pessin-Minsley MS, Urtecho J et al (2002) Right ventricular dysfunction and organ failure in left ventricular assist device recipients: a continuing problem. Ann Thorac Surg 73:745–750
Lazar RM, Shapiro PA, Jaski BE et al (2004) Neurological events during long-term mechanical circulatory support for heart failure: the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) experience. Circulation 109:2423–2427
Rose EA, Gelijns AC, Moskowitz AJ et al (2001) Long-term mechanical left ventricular assistance for end-stage heart failure. N Engl J Med 345:1435–1443
Tsukui H, Teuteberg JJ, Murali S et al (2005) Biventricular assist device utilization for patients with morbid congestive heart failure: a justifiable strategy. Circulation 112:I65–I72
Piccione W Jr (2000) Left ventricular assist device implantation: short and long-term surgical complications. J Heart Lung Transplant 19:S89–S94
Warnecke H, Berdjis F, Hennig E et al (1991) Mechanical left ventricular support as a bridge to cardiac transplantation in childhood. Eur J Cardiothorac Surg 5:330–333
Sinha P, Chen JM, Flannery M, Scully BE, Oz MC, Edwards NM (2000) Infections during left ventricular assist device support do not affect posttransplant outcomes. Circulation 102:III194–III199
Acknowledgements
This research has been supported by the National Center of Competence in Research, Computer Aided and Image Guided Medical Interventions (NCCR CO-ME) of the Swiss National Science Foundation.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Scheffel, H., Stolzmann, P., Wilhelm, M.J. et al. Conventional radiography and computed tomography of cardiac assist devices. Eur Radiol 19, 2097–2106 (2009). https://doi.org/10.1007/s00330-009-1406-6
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-009-1406-6