Abstract
Purpose
This paper investigates the relationship between core temperature (T c), skin temperature (T s) and heat flux (HF) during exercise in hot conditions.
Method
Nine test volunteers, wearing an Army Combat Uniform and body armor, participated in three sessions at 25 °C/50 % relative humidity (RH); 35 °C/70 % RH; and 42 °C/20 % RH. Each session consisted of two 1-h treadmill walks at ~350 W and ~540 W intensity. T s and HF from six sites on the forehead, sternum, pectoralis, left rib cage, left scapula, and left thigh, and T c (i.e., core temperature pill used as a suppository) were measured. Multiple linear regressions were conducted to derive algorithms that estimate T c from T s and HF at each site. A simple model was developed to simulate influences of thermal conductivity and thickness of the local body tissues on the relationship between T c, T s, and HF.
Results
Coefficient of determination (R 2) ranged from 0.30 to 0.88, varying with locations and conditions. Good sites for T c measurement at surface were the sternum, and a combination of the sternum, scapula, and rib sites. The combination of T s and HF measured at the sternum explained ~75 % or more of variance in observed T c in hot environments. The forehead was found unsuitable for exercise in heat due to sweating and evaporative heat loss. The derived algorithms are likely applicable only for the same ensemble or ensembles with similar thermal and vapor resistances.
Conclusion
Algorithms for T c measurement are location-specific and their accuracy is dependent, to a large degree, on sensor placement.
Similar content being viewed by others
References
Armed Forces Health Surveillance Center (2012) Heat injuries, active component, U.S. Armed Force, 2011. MSMR 19:14–16
Bernard TE, Kenney WL (1994) Rationale for a personal monitor for heat strain. Am Ind Hyg Assoc J 55:505–514
Bonauto DB, Anderson R, Rauser E, Burke B (2007) Occupational heat illness in Washington State, 1995–2005. Am J Ind Med 50:940–950
Buller MJ, Castellani J, Robert WS, Hoyt RW, Jenkins OC (2011) Human thermoregulatory system state estimation using non-invasive physiological sensors. Conf Proc IEEE Eng Med Biol Soc 2011:3290–3293
Centers for Disease Control and Prevention (2008) Heat-related deaths among crop workers—United States, 1992–2006. MMWR Morb Mortal Wkly Rep 57:649–653
DeGroot DW, Havenith G, Kenney WL (2006) Responses to mild cold stress are predicted by different individual characteristics in young and older subjects. J Appl Physiol 101:1607–1615
Dittmar A, Gehin C, Delhomme G, Boivin D, Dumont G, Mott C (2006) A non-invasive wearable sensor for the measurement of brain temperature. Engineering in Medicine and Biology Society, 2006 EMBS 06, 28th Annual International Conference of the IEEE, 900–902
Donoghue AM (2004) Heat illness in the U.S. mining industry. Am J Ind Med 45:351–356
Fox J (1991) Regression diagnostics: an introduction. Sage, Newbury Park
Fox RH, Solman AJ (1971) A new technique for monitoring the deep body temperature in man from the intact skin surface. J. Physiol 212:8–10
Gunga HC, Sandsund M, Reinerrsen RE, Sattler F, Koch J (2008) A non-invasive device to continuously determine heat strain in humans. J Therm Biol 33:297–307
Gunga HC, Werner A, Stahn A, Steich M, Schlabs T, Koralewski E, Kunz D, Belavy DL, Felsenberg D, Sattler F, Koch J (2009) The Double Sensor—a non-invasive device to continuously monitor core temperature in humans on earth and in space. Respir Physiol Neurobiol 169:S63–S68
Havenith G, Coenen J, Kistermaker L, Kenney WL (1998) The relevance of individual characteristics for human heat stress response is dependent on work intensity and climate type. Eur J Appl Physiol 77:231–241
Howe AS, Boden BP (2007) Heat-related illness in athletes. Am J Sports Med 35:1384–1395
Huang M, Chen W (2010) Theoretical simulation of the dual-heat-flux method in deep body temperature measurements. In: 32nd Annual International Conference of the IEEE EBS, 561–564
Kimberger O, Thell R, Schuh M, Koch J, Sessler DI, Kurz A (2009) Accuracy and precision of a novel non-invasive core thermometer. Br J Anaesth 103:226–231
Kitamura KI, Zhu X, Chen W, Nemoto T (2010) Development of a new method for the noninvasive measurement of deep body temperature without a heater. Med Eng Phys 32:1–6
Machado-Moreira CA, Wilmink F, Meijer A, Mekjavic IB, Taylor NAS (2007) Chrome domes: sweat secretion from the head during thermal strain. In: Mekjavic IB, Kounalakis SN, Taylor NAS (eds) Proceedings of 12th International Conference on Environmental Ergonomics. Piran, Slovenia, pp. 272–274
O’Brien C, Hoyt RW, Buller MJ, Castellani JW, Young AJ (1998) Telemetry pill measurement of core temperature in humans during active heating and cooling. Med Sci Sports Exerc 30(3):468–472
Pandolf K, Givoni B, Goldman RF (1977) Predicting energy expenditure with loads while standing or walking very slowly. J. Appl. Physiol Respir Environ Exerc Physiol 43:577–581
Shitzer A, Stroschein LA, Gonzalez RR, Pandolf K (1996) Lumped-parameter tissue temperature-blood perfusion model of a cold-stress fingertip. J Appl Physiol 80:1829–1834
Steck LN, Sparrow EM, Abraham JP (2011) A non-invasive measurement of the human core temperature. Int J Heat Mass Transf 54:975–982
Taylor NAS, Amos D (1997) Insulated skin temperature and cardiac frequency as indices of thermal strain during work in hot environments. Technical Report DSTO-TR-0590, Defense Science and Technology Organization, Australia
Taylor NAS, Wilsmore BR, Amos D, Takken T, Komen T, Cotter JD, Jenkins A (1998) Indirect measurement of core temperature during work: clothing and environment influences. In: Hodgdon JA, Heaney JH, Buono MJ (eds) Environmental Ergonomics VIII. Naval Health Research Center and San Diego State University, San Diego
Teunissen LPJ, Klewer J, Sterz F, Haan AD, Koning JJD, Daanen HAM (2011) A non-invasive continuous temperature measurement by zero heat flux. Physiol Meas 32:559–570
Tharion WJ, Buller MJ, Karis AJ, Hoyt RW (2010) Development of a remote medical monitoring system to meet soldier needs. In: Karowski W, Salvendy G (eds), Proceedings of the 3rd International Conference on Applied Human Factors and Ergonomics. USA Publishing, Louisville
Wan M (2006) Assessment of occupational heat strain. PhD Thesis, University of South Florida
Werner J, Buse M (1988) Temperature profiles with respect to inhomogeneity and geometry of the human body. J Appl Physiol 65:1110–1118
Wikinson DM, Carter JM, Richmond VL, Backer SD, Rayson MP (2008) The effect of cool water ingestion on gastrointestinal pill temperature. Med Sci Sports Exerc 40:523–528
Yamakage M, Namiki A (2003) Deep temperature monitoring using a zero-heat-flow method. J Anesth 17:108–115
Zeiner A, Klewer J, Sterz F, Haugk M, Krizanac D, Testori C, Losert H, Ayati S, Holzer M (2010) A non-invasive continuous cerebral temperature monitoring in patients treated with mild therapeutic hypothermia: an observation pilot study. Resuscitation 81:861–866
Acknowledgments
We would like thank to the volunteers who endured the experimental heat trials. We would also like to thank Dr. Reed Hoyt for his critical review and comments of this manuscript. We would like to acknowledge and thank Mr. Stephen Mullen, Patel Tejash, Timothy Rioux, Julio Gonzalez, William Tharion, Alex Welles, and Ms. Laurie Blanchard for their technical assistance in the collection, organization, and analysis of the study data.
Disclaimer
This study is approved for public release; distribution is unlimited. The opinions or assertions contained herein are the private views of the author(s) and are not to be construed as official or reflecting the views of the Army or the Department of Defense. The investigators have adhered to the policies for protection of human subjects as prescribed in Army Regulation 70-25, and the research was conducted in adherence with the provisions of 32 CFR Part 219. Human subjects participated in these studies after giving their free and informed voluntary consent. Investigators adhered to AR 70-25 and USAMRMC Regulation 70-25 on the use of volunteers in research. Any citations of commercial organizations and trade names in this report do not constitute an official Department of the Army endorsement of approval of the products or services of these organizations.
Author information
Authors and Affiliations
Corresponding author
Additional information
Communicated by George Havenith.
Rights and permissions
About this article
Cite this article
Xu, X., Karis, A.J., Buller, M.J. et al. Relationship between core temperature, skin temperature, and heat flux during exercise in heat. Eur J Appl Physiol 113, 2381–2389 (2013). https://doi.org/10.1007/s00421-013-2674-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00421-013-2674-z