Boyd SG, Rothwell JC, Cowan JMA, Webb PJ, Morley T, Asselman P, Marsden CD (1986) A method of monitoring function in cortical pathways during scoliosis surgery with a note on motor conduction velocities. J Neurol Neurosurg Psych 49:251–257
Calancie B, Madsen P, Lebwohl N (1994) Stimulus-evoked EMG monitoring during transpedicular lumbosacral spine instrumentation: Initial clinical results. Spine 19:2780–2786
Deletis V (1993) Intraoperative monitoring of the functional integrity of the motor pathways. In: Devinsky O, Beric A, Dogali M (eds) Advances in neurology: electrical and magnetic stimulation of the brain. Raven, New York, pp 201–214
Deletis V, Kiprovski K, Neuwirth M, Engler G (1994) Do neurogenic lesions of the spinal cord generate distinctive features of the epidurally recorded motor evoked potentials? In: Jones SJ, Boyd SM, Smith NJ (eds) Handbook of spinal cord monitoring. Kluwer, Dordrecht, pp 266–271
Deletis V (2001) The “motor” inaccuracy in neurogenic motor evoked potentials (Editorial). Clin Neurophys 112:1365–1366
Deletis V (2002) Intraoperative neurophysiology and methodology used to monitor the functional integrity of the motor system. In: Deletis V, Shils J (eds) Neurophysiology in neurosurgery. A modern intraoperative approach. Academic, Dublin, pp 25–51
Halonen JP, Jones SJ, Edgar MA, Ransford AO (1989) Conduction properties of epidurally recorded spinal cord potentials following lower limb stimulation in man. EEG Clin Neurophysiol 74:161–174
Hicks R, Burke D, Stephen J, Woodforth I, Crawford M (1992) Corticospinal volleys evoked by electrical stimulation of human motor cortex after withdrawal of volatile anesthetics. J Physiol (London) 456:393–404
Jones SJ, Buonamassa S, Crockard HA (2003) Two cases of quadriparesis following anterior cervical discectomy, with normal perioperative somatosensory evoked potentials. J Neurol Neurosurg Psych 44:273–276
Lesser RP, Raudzens P, Lüders H, Nuwer MR, Goldie WD, Morris HH, Dinner DS, Klem G, Hahn JF, Shetter AG, Ginsburg HH, Gurd AR (1986) Postoperative neurological deficits may occur despite unchanged intraoperative somatosensory evoked potentials. Ann Neurol 19:22–25
Machida M, Weinstein SL, Yamada T, Kimura J (1985) Spinal cord monitoring––electrophysiological measures of sensory and motor function during spinal surgery. Spine 10:407–413
Minahan RE, Sepkuty JP, Lesser RP, Sponseller PD, Kostuik JP (2001) Anterior spinal cord injury with preserved neurogenic ‘motor’ evoked potentials. Clin Neurophysiol 112:1442–1450
Owen JH, Laschinger J, Bridwell K, Shiman S, Nielsen C, Dunlap J, Kain C (1988) Sensitivity and specificity of somatosensory and neurogenic-motor evoked potentials in animals and humans. Spine 19(10):1111–1117
Patton HD, Amassian VE (1954) Single and multiple unit analysis of cortical state of pyramidal tract activation. J Neurophysiol 17:345–363
Pechstein U, Cedzich C, Nadstawek J, Schramm J (1996) Transcranial high-frequency repetitive electrical stimulation of recording myogenic motor evoked potential with the patient under general anesthesia. Neurosurgery 39:335–344
Pelosi L, Jardine A, Webb JK (1999) Neurological complications of anterior spinal surgery for kyphosis with normal somatosensory evoked potentials (SEPs). J Neurol Neurosurg Psych 66:662–664
Szelenyi A, Kothbauer K, Deletis V (2007) Transcranial electric stimulation for intraoperative motor evoked potential monitoring: stimulation parameters and electrode montages. Clinical Neurophysiol 118:1586–1595
Taylor BA, Taylor A, Farrell J (1993) Temporal summation––the key to motor evoked potential spinal cord monitoring in humans. J Neurol Neurosurg Psychiatry 56:104–106
Tamaki T, Takano H, Takakuwa K (1985) Spinal cord monitoring: Basic principles and experimental aspects. Cent Nerv Syst Trauma 2:137–149
Taniguchi M, Cedzich C, Schramm J (1993) Modification of cortical stimulation for motor evoked potentials under general anesthesia: technical description. Neurosurgery 32(2):219–226
Toleikis JR, Skelly JP, Carlvin AO, Burkus JK (2000) Spinally elicited peripheral nerve responses are sensory rather than motor. Clin Neurophysiol 111:736–742
Toleikis R (2002) Neurophysiological monitoring during pedicle screw placement. In: Deletis V, Shils J (eds) Neurophysiology in neurosurgery. A modern intraoperative approach. Academic, Dublin, pp 231–259
Ulkatan S, Neuwirth M, Bitan F, Minardi C, Kokoszka A, Deletis V (2006) Monitoring of scoliosis surgery with epidurally recorded motor evoked potentials (D Wave) revealed false results. Clin Neurophysiol 117:2093–2101
Conflict of interest statement None of the authors has any potential conflict of interest.