Experimental Mechanics (2017) 57:1483-1493

https://doi.org/10.1007/s11340-017-0314-y

In the above article, due to a systematic error in analysing the thickness of the fracture, property values were calculated using half the actual value of w. Thus, the y-axis values in Fig. 4b will be twice as large. Consequently, in Table 1 and Fig. 6, the values for the stress intensity KI will be doubled and the fracture energy values γs are four times larger due to the relation with KI. This does not change the qualitative behaviour of these results described in the paper or the overall conclusions of the paper.