Abstract
Purpose
Abdominal aortic aneurysm (AAA) is a localized, permanent and irreversible enlargement of the artery, with the formation of thrombus into the inner wall of the aneurysm. A precise patient-specific segmentation of the thrombus is useful for both the pre-operative planning to estimate the rupture risk, and for post-operative assessment to monitor the disease evolution. This paper presents a generic approach for 3D segmentation of thrombus from patients suffering from AAA using computed tomography angiography (CTA) scans.
Methods
A fast and versatile thrombus segmentation approach has been developed. It is composed of initial centerline detection and aorta lumen segmentation, an optimized pre-processing stage and the use of a 3D deformable model. The approach has been designed to be very generic and requires minimal user interaction. The proposed method was tested on different datasets with 145 patients overall, including pre- and post-operative CTAs, abdominal aorta and iliac artery sections, different calcification degrees, aneurysm sizes and contrast enhancement qualities.
Results
The thrombus segmentation approach showed very accurate results with respect to manual delineations for all datasets (\(\hbox {Dice} = 0.86 \pm 0.06, 0.81 \pm 0.06\) and \(0.87 \pm 0.03\) for abdominal aorta sections on pre-operative CTA, iliac artery sections on pre-operative CTAs and aorta sections on post-operative CTA, respectively). Experiments on the different patient and image conditions showed that the method was highly versatile, with no significant differences in term of precision. Comparison with the level-set algorithm also demonstrated the superiority of the 3D deformable model. Average processing time was \(8.2 \pm 3.5 \hbox { s}\).
Conclusion
We presented a near-automatic and generic thrombus segmentation algorithm applicable to a large variability of patient and imaging conditions. When integrated in an endovascular planning system, our segmentation algorithm shows its compatibility with clinical routine and could be used for pre-operative planning and post-operative assessment of endovascular procedures.
Similar content being viewed by others
References
Sakalihasan N, Limet R, Defawe O (2005) Abdominal aortic aneurysm. Lancet 365:1577–1589
Wever JJ, Blankensteijn JD, Mali WTM, Eikelboom BC (2000) Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg 20:177–182
Walker GT, Kalva SP, Yeddula K, Wicky S, Kundu S, Dresher P, d’Othee J, Rose SC, Cardella JF (2010) Clinical practice guidelines for endovascular abdominal aortic aneurysm repair: written by the standards of practice committee for the society of interventional radiology and endorsed by the cardiovascular and interventional radiological society of Europe and the Canadian interventional radiology association. J Vasc Interv Radiol 21:1632–1655
Martinez-Muñoz S, Ruiz-Fernandez D, Galiana-Merino JJ (2016) Automatic abdominal aortic aneurysm segmentation in MR images. Exp Syst Appl 54:78–87
Rodriguez-Vila B, Tarjuelo-Gutierrez J, Sánchez-González P, Verbrugghe P, Fourneau I, Maleux G, Herijgers P, Gomez EJ (2015) Automated delineation of vessel wall and thrombus boundaries of abdominal aortic aneurysms using multispectral MR images. Comput Math Methods Med 2015:e202539
Shiffman S, Rubin GD, Napel S (1996) Semiautomated editing of computed tomography sections for visualization of vasculature. Presented at the April 15
Loncaric S, Subasic M, Sorantin, E (2000) 3-D deformable model for aortic aneurysm segmentation from CT images. In: Proceedings of the 22nd annual international conference of the IEEE engineering in medicine and biology society, 2000, vol 1, pp 398–401
Zohios C, Kossioris G, Papaharilaou Y (2012) Geometrical methods for level set based abdominal aortic aneurysm thrombus and outer wall 2D image segmentation. Comput Methods Programs Biomed 107:202–217
Kossioris G, Papaharilaou Y, Zohios C (2008) Detection of lumen, thrombus and outer wall boundaries of an abdominal aortic aneurysm From 2D medical images using level set methods. In: Proceedings of ASME Summer Bioengineering Conference, Marco Island, 25–29 June 2008. pp 889–890
Subasić M, Loncarić S, Sorantin E (2005) Model-based quantitative AAA image analysis using a priori knowledge. Comput Methods Programs Biomed 80:103–114
Subasic M, Loncaric S, Sorantin E (2003) Region-based deformable model for aortic wall segmentation. In: Proceedings of the 3rd international symposium on image and signal processing and analysis, 2003, vol 2. ISPA 2003. pp 731–735
Demirci S, Lejeune G, Navab N (2009) Hybrid deformable model for aneurysm segmentation. In: IEEE international symposium on biomedical imaging: from nano to macro, 2009. ISBI ’09, pp 33–36
de Bruijne M, van Ginneken B, Viergever MA, Niessen WJ (2004) Interactive segmentation of abdominal aortic aneurysms in CTA images. Med Image Anal 8:127–138
de Bruijne M, van Ginneken B, Viergever MA, Niessen WJ (2003) Adapting active shape models for 3D segmentation of tubular structures in medical images. Inf Process Med Imaging Proc Conf 18:136–147
Das B, Mallya Y, Srikanth S, Malladi R (2006) Aortic thrombus segmentation using narrow band active contour model. In: Conference proceedings of the annual international conference of the IEEE engineering in medicine and biology society IEEE engineering in medicine biology society annual conference, vol 1, pp 408–411
Dehmeshki J, Amin H, Ebadian-dehkordi M, Jouannic A, Qanadli S (2009) Automatic detection, segmentation and quantification of abdominal aortic aneurysm using computed tomography angiography. In: Proceedings of the medical image understanding and analysis, pp 32–36
Maiora J, Papakostas GA, Kaburlasos VG, Grana M (2014) A proposal of texture features for interactive CTA segmentation by active learning. Stud Health Technol Inform 207:311–320
Maiora J, Graña M (2012) Abdominal CTA image analysis through active learning and decision random forests: Application to AAA segmentation. In: The 2012 international joint conference on neural networks (IJCNN), pp 1–7
Macía I, Arenas M, Legarreta JH, Robin I, Graña M, Rajasekharan S (2012) Fast AAA thrombus segmentation from CTA images for endovascular repair follow-up. In: Medical image computing and computer-assisted intervention–MICCAI 2012 15th international conference, vol 7510. Springer, Berlin, pp 72–79
Macía I, Graña M, Maiora J, Paloc C, de Blas M (2011) Detection of type II endoleaks in abdominal aortic aneurysms after endovascular repair. Comput Biol Med 41:871–880
Lee K, Johnson RK, Yin Y, Wahle A, Olszewski ME, Scholz TD, Sonka M (2010) Three-dimensional thrombus segmentation in abdominal aortic aneurysms using graph search based on a triangular mesh. Comput Biol Med 40:271–278
Lee K, Yin Y, Wahle A, Olszewski ME, Sonka M (2008) 3-D segmentation and quantitative analysis of inner and outer walls of thrombotic abdominal aortic aneurysms. In: Hu XP, Clough AV (eds) Medical imaging 2008: physiology, function, and structure from medical images, vol 6916, SPIE Proceedings, Bellingham, WA, pp 691626.1–691626-9. doi:10.1117/12.773394
Freiman M, Esses SJ, Joskowicz L, Sosna J (2010) AN iterative model-constrained graph-cut algorithm for abdominal aortic aneurysm thrombus segmentation. In: 2010 IEEE international symposium on biomedical imaging: from nano to macro, pp 672–675
Olabarriaga SD, Rouet J-M, Fradkin M, Breeuwer M, Niessen WJ (2005) Segmentation of thrombus in abdominal aortic aneurysms from CTA with nonparametric statistical grey level appearance modeling. IEEE Trans Med Imaging 24:477–485
Zhuge F, Rubin GD, Sun S, Napel S (2006) An abdominal aortic aneurysm segmentation method: level set with region and statistical information. Med Phys 33:1440–1453
Insight Journal (ISSN 2327-770X)—Fast marching minimal path extraction in ITK, http://www.insight-journal.org/browse/publication/213
Kaladji A, Lucas A, Kervio G, Haigron P, Cardon A (2010) Sizing for endovascular aneurysm repair: clinical evaluation of a new automated three-dimensional software. Ann Vasc Surg 24:912–920
Subasic M, Loncaric S, Sorantin E (2000) 3-D image analysis of abdominal aortic aneurysm. Stud Health Technol Inform 77:1195–1200
Kass M, Witkin A, Terzopoulos D (1988) Snakes: active contour models. Int J Comput Vis 1:321–331
Chaikof EL, Blankensteijn JD, Harris PL, White GH, Zarins CK, Bernhard VM, Matsumura JS, May J, Veith FJ, Fillinger MF, Rutherford RB, Kent KC (2002) Ad hoc committee for standardized reporting practices in vascular surgery of the society for vascular surgery/American association for vascular surgery: reporting standards for endovascular aortic aneurysm repair. J Vasc Surg 35:1048–1060
Sethian J (1999) Fast marching methods. SIAM Rev 41:199–235
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Rights and permissions
About this article
Cite this article
Lalys, F., Yan, V., Kaladji, A. et al. Generic thrombus segmentation from pre- and post-operative CTA. Int J CARS 12, 1501–1510 (2017). https://doi.org/10.1007/s11548-017-1591-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11548-017-1591-8