Abstract
Objective
To describe the long-term results, quality of life and chronic pain after chest wall fixation for traumatic rib fracture using a quality of life (QOL) score and a numeric pain score.
Methods
Retrospective analysis of 10 consecutive patients who underwent surgery for rib fractures after trauma and reconstruction between October 2010 and March 2012. Chest rib fractures were fixed with titanium clips and bars or titanium plates and screws through a posterolateral thoracotomy. Pain was assessed with a numeric pain scale 0–10 and quality of life (QOL) with the EORTC questionnaire QLQ-C30.
Results
There were 5 males and 5 females. The median age was 58 years (range 21–80). There were no postoperative deaths. The only postoperative complication observed was a contralateral pleural effusion requiring drainage. Median length of stay of the drain and median length of hospital stay were 2 days (range 0–8) and 4 days (range 1–42 days), respectively. The average follow-up period of operatively managed patients was 14 months (range 8–23.5 months). Seven patients scored the pain as 0, one as 1 (mild), one as 4 (moderate) and one as 8 (severe). Only two patients are taking occasionally pain killers. Only one patient presents severe limitation in his life scoring his QOL as poor.
Conclusions
Titanium devices (clips and bars; screws and plates) are effective and safe for repair of rib fractures and showed good long-term results in terms of pain and quality of life after the operation.
Similar content being viewed by others
References
Richardson JD, Franklin GA, Heffley S, Seligson D. Operative fixation of chest wall fractures: an underused procedure? Am Surg. 2007;73:591–6.
Tanaka H, Yukioka T, Yamaguti Y, et al. Surgical stabilization or internal pneumatic stabilization? A prospective randomized study of management of severe flail chest patients. J Trauma. 2002;52:727–32.
Granetzny A, Abd El-Aal M, Emam E, Shalaby A, Boseila A. Surgical versus conservative treatment of flail chest. Evaluation of the pulmonary status. Interact Cardiovasc Thorac Surg. 2005;4:583–7.
de Moya M, Bramos T, Agarwal S, Fikry K, Janjua S, King DR, Alam HB, Velmahos GC, Burke P, Tobler W. Pain as an indication for rib fixation: a bi-institutional pilot study. J Trauma. 2011;71:1750–4.
Cacchione RN, Richardson JD, Seligson D. Painful nonunion of multiple rib fractures managed by operative stabilization. J Trauma. 2000;48:319–21.
Fayers PM, Aaronson NK, Bjordal K, Groenvold M, Curran D, Bottomley A, on behalf of the EORTC Quality of Life Group. The EORTC QLQ-C30 scoring manual. 3rd ed. Brussels: European Organisation for Research and Treatment of Cancer; 2001.
Mayberry JC, Kroeker AD, Ham LB, Mullins RJ, Trunkey DD. Long-term morbidity, pain, and disability after repair of severe chest wall injuries. Am Surg. 2009;75(5):389–94.
Girsowicz E, Falcoz PE, Santelmo N, Massard G. Does surgical stabilization improve outcomes in patients with isolated multiple distracted and painful non-flail rib fractures? Interact Cardiovasc Thorac Surg. 2012;14(3):312–5.
Bulger EM, Arneson MA, Mock CN, Jurkovich GJ. Rib fractures in the elderly. Trauma. 2000;48:1040–6.
Gasparri MG, Tissol WB, Haasler GB. Rib stabilization: lessons learned. Eur J Trauma Emerg Surg. 2010;36:435–40.
Campbell N, Conaglen P, Martin K, Antippa P. Surgical stabilization of rib fractures using Inion OTPS wraps–techniques and quality of life follow-up. J Trauma. 2009;67:596–601.
Acknowledgments
No funding was obtained for this research. The companies manufacturing these devices did not provide any economical or logistic support. All the operations were funded by the United Kingdom National Health Service.
Conflict of interest
None declared.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Billè, A., Okiror, L., Campbell, A. et al. Evaluation of long-term results and quality of life in patients who underwent rib fixation with titanium devices after trauma. Gen Thorac Cardiovasc Surg 61, 345–349 (2013). https://doi.org/10.1007/s11748-013-0218-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11748-013-0218-4