A machining workshop requires ventilation that removes oil mist particles efficiently and conditions air to a comfortable temperature. Displacement ventilation has been reported to be highly efficient in removing airborne pollutants in a workshop. However, the traditional wall-mounted displacement ventilation system may be inadequate for delivering conditioned, clean air to the internal zone of a large-span workshop. This investigation proposed an improved wall-mounted displacement ventilation system in which machining equipment is elevated, relay fans are operated in corridors in the cooling season, and ceiling air exhausts are lowered. The proposed ventilation system was compared with the traditional wall-mounted displacement ventilation system and a displacement ventilation system with multiple local diffusers in the corridors, separately. A validated computational fluid dynamics (CFD) software program was used to investigate the three ventilation systems in both the cooling and heating seasons. The airflow, oil mist particle concentration, and air temperature under the three ventilation systems were evaluated. The results revealed that the traditional wall-mounted displacement ventilation system is inappropriate for use in a large-span workshop, particularly in the cooling season. The proposed improved wall-mounted displacement ventilation provided the lowest oil mist particle concentration in the breathing zone and an appropriate air temperature in the occupied zone in both the cooling and heating seasons. Notably in the cooling season, the proposed system reduced the oil mist particle concentration by 48.5% in the breathing zone as compared with the traditional system. Such an improved ventilation system is highly recommended for use in large-span workshops.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • ASHRAE (2017a). ASHRAE Handbook—Fundamentals. Atlanta, GA, USA: American Society of Heating, Ventilating and Air-Conditioning Engineers.

    Google Scholar 

  • ASHRAE (2017b). Thermal Environmental Conditions for Human Occupancy. Atlanta, GA, USA: American Society of Heating, Ventilating and Air-Conditioning Engineers.

    Google Scholar 

  • Belin K (1978). Allmaen Ventilation Med Displacerande Stroemning. BFR-rapport R 77:1978, Stockholm.

  • Braconnier R (1988). Bibliographic review of velocity fields in the vicinity of local exhaust hood openings. American Industrial Hygiene Association Journal, 49: 185–198.

    Article  Google Scholar 

  • Breum NO (1988). Air exchange efficiency of displacement ventilation in a printing plant. Annals of Occupational Hygiene, 32: 481–488.

    Google Scholar 

  • Bukowski JA (2003). Review of respiratory morbidity from occupational exposure to oil mists. Applied Occupational and Environmental Hygiene, 18: 828–837.

    Article  Google Scholar 

  • Cao G, Awbi H, Yao R, et al. (2014). A review of the performance of different ventilation and airflow distribution systems in buildings. Building and Environment, 73: 171–186.

    Article  Google Scholar 

  • Cao Z, Zhai C, Wang Y, et al. (2020). Flow characteristics and pollutant removal effectiveness of multi-vortex ventilation in high pollution emission industrial plant with large aspect ratio. Sustainable Cities and Society, 54: 101990.

    Article  Google Scholar 

  • Cao Y, Wang Y, Yu Z, et al. (2022). Spatio-temporal distribution of gaseous pollutants from multiple sources in industrial buildings with different flow patterns. Building Simulation, 15: 1629–1644.

    Article  Google Scholar 

  • Chen C, Lai D, Chen Q (2020). Energy analysis of three ventilation systems for a large machining plant. Energy and Buildings, 224: 110272.

    Article  Google Scholar 

  • Choudhury D (1993). Introduction to the renormalization group method and turbulence modeling. Fluent Inc. Technical Memorandum TM-107.

  • Dou X, Xie D, Wang Z, et al. (2021). Improved buoyancy-driver hybrid ventilation system for multiple-heat-source industrial buildings. Case Studies in Thermal Engineering, 26: 101059.

    Article  Google Scholar 

  • Eisen EA, Smith TJ, Kriebel D, et al. (2001). Respiratory health of automobile workers and exposures to metal-working fluid aerosols: Lung spirometry. American Journal of Industrial Medicine, 39: 443–453.

    Article  Google Scholar 

  • Goodfellow HD, Wang Y (2021). Industrial Ventilation Design Guidebook, Volume 2: Engineering Design and Applications. London: Academic Press

    Google Scholar 

  • Lai ACK, Nazaroff WW (2000). Modeling indoor particle deposition from turbulent flow onto smooth surfaces. Journal of Aerosol Science, 31: 463–476.

    Article  Google Scholar 

  • Mirer FE (2010). New evidence on the health hazards and control of metalworking fluids since completion of the OSHA advisory committee report. American Journal of Industrial Medicine, 53: 792–801.

    Article  Google Scholar 

  • Moon J, Heo J, Moon S, et al. (2005). Improvement of indoor air environment in a large welding factory by displacement ventilation. In: Proceedings of the SAREK Conference, R.O. Korea.

  • Nielsen PV (1993). Displacement Ventilation Theory and Design. Department of Building Technology and Structural Engineering, Aalborg University, Denmark.

    Google Scholar 

  • NIOSH (1998). Criteria for a Recommended Standard: Occupational Exposure to Metalworking Fluids. National Institute for Occupational Safety and Health (NIOSH).

  • Rohdin P, Moshfegh B (2011). Numerical modelling of industrial indoor environments: A comparison between different turbulence models and supply systems supported by field measurements. Building and Environment, 46: 2365–2374.

    Article  Google Scholar 

  • Sokolović DS, Höflinger W, Šečerov Sokolović RM, et al. (2013). Experimental study of mist generated from metalworking fluids emulsions. Journal of Aerosol Science, 61: 70–80.

    Article  Google Scholar 

  • Teodosiu C, Kuznik F, Teodosiu R (2014). CFD modeling of buoyancy driven cavities with internal heat source—Application to heated rooms. Energy and Buildings, 68: 403–411.

    Article  Google Scholar 

  • Wang H, Huang C, Liu D, et al. (2012). Fume transports in a high rise industrial welding hall with displacement ventilation system and individual ventilation units. Building and Environment, 52: 119–128.

    Article  Google Scholar 

  • Wang Y, Cao Y, Liu B, et al. (2016). An evaluation index for the control effect of the local ventilation systems on indoor air quality in industrial buildings. Building Simulation, 9: 669–676.

    Article  Google Scholar 

  • Wang F, Li Z, Wang P, et al. (2018a). Experimental study of oil particle emission rate and size distribution during milling. Aerosol Science and Technology, 52: 1308–1319.

    Article  Google Scholar 

  • Wang H, Sun L, Guan H, Hu S (2018b). Thermal environment investigation and analysis on thermal adaptation of workers in a rubber factory. Energy and Buildings, 158: 1625–1631.

    Article  Google Scholar 

  • Wang Y, Zhai C, Zhao T, et al. (2020). Numerical study on pollutant removal performance of vortex ventilation with different pollution source locations. Building Simulation, 13: 1373–1383.

    Article  Google Scholar 

  • Wei G, Chen B, Lai D, et al. (2020). An improved displacement ventilation system for a machining plant. Atmospheric Environment, 228: 117419.

    Article  Google Scholar 

  • Yakhot V, Orszag SA, Thangam S, et al. (1992). Development of turbulence models for shear flows by a double expansion technique. Physics of Fluids A: Fluid Dynamics, 4: 1510–1520.

    Article  MathSciNet  Google Scholar 

  • Yang B, Melikov AK, Kabanshi A, et al. (2019). A review of advanced air distribution methods—Theory, practice, limitations and solutions. Energy and Buildings, 202: 109359.

    Article  Google Scholar 

  • Zhang Z, Chen Q (2007). Comparison of the Eulerian and Lagrangian methods for predicting particle transport in enclosed spaces. Atmospheric Environment, 41: 5236–5248.

    Article  Google Scholar 

  • Zhang Z, Zhang W, Zhai ZJ, et al. (2007). Evaluation of various turbulence models in predicting airflow and turbulence in enclosed environments by CFD: Part 2—Comparison with experimental data from literature. HVAC and R Research, 13(6), 871–886.

    Article  Google Scholar 

  • Zhang T, Lee K, Chen Q (2009). A simplified approach to describe complex diffusers in displacement ventilation for CFD simulations. Indoor Air, 19: 255–267.

    Article  Google Scholar 

  • Zhang T, Li P, Wang S (2012). A personal air distribution system with air terminals embedded in chair armrests on commercial airplanes. Building and Environment, 47: 89–99.

    Article  Google Scholar 

  • Zhang J, Long Z, Liu W, et al. (2016a). Strategy for studying ventilation performance in factories. Aerosol and Air Quality Research, 16: 442–452.

    Article  Google Scholar 

  • Zhang J, Shao Y, Long Z (2016b). Physicochemical characterization of oily particles emitted from different machining processes. Journal of Aerosol Science, 96: 1–13.

    Article  Google Scholar 

Download references

Acknowledgements

This research was supported by the National Key R&D Program of the Ministry of Science and Technology, China, on “Green Buildings and Building Industrialization” through Grant No. 2018YFC0705300.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tengfei (Tim) Zhang.

Electronic supplementary material

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Liu, F., Zhang, T., Yang, L. et al. An improved wall-mounted displacement ventilation system in a large-span machining workshop. Build. Simul. 15, 1943–1953 (2022). https://doi.org/10.1007/s12273-022-0906-z

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-022-0906-z

Keywords

Navigation