Abstract
In this study, we report on the development of a novel nebulizer configuration for sonic-spray ionization (SSI) mass spectrometry (MS), more specifically for a version of SSI that is referred to as Venturi easy ambient sonic-spray ionization (V-EASI) MS. The developed nebulizer configuration is based on a commercially available pneumatic glass nebulizer that has been used extensively for aerosol formation in atomic spectrometry. In the present study, the nebulizer was modified in order to achieve efficient V-EASI-MS operation. Upon evaluating this system, it has been demonstrated that V-EASI-MS offers some distinct advantages for the analysis of coordination compounds and redox active inorganic compounds over the predominantly used electrospray ionization (ESI) technique. Such advantages, for this type of compounds, are demonstrated here for the first time. More specifically, a series of labile heptanuclear heterometallic [CuII 6LnIII] clusters held together with artificial amino acid ligands, in addition to easily oxidized inorganic oxyanions of selenium and arsenic, were analyzed. The observed advantages pertain to V-EASI appearing to be a “milder” ionization source than ESI, not requiring electrical potentials for gas phase ion formation, thus eliminating the possibility of unwanted redox transformations, allowing for the “simultaneous” detection of negative and positive ions (bipolar analysis) without the need to change source ionization conditions, and also not requiring the use of syringes and delivery pumps. Because of such features, especially because of the absence of ionization potentials, EASI can be operated with minimal requirements for source parameter optimization. We observed that source temperature and accelerating voltage do not seem to affect labile compounds to the extent they do in ESI-MS. In addition, bipolar analysis of proteins was demonstrated here by acquiring both positive and negative ion mass spectra from the same protein solutions, without the need to independently adjust solution and source conditions in each mode. Finally, the simple and efficient operation of a dual-nebulizer configuration was demonstrated for V-EASI-MS for the first time.
Similar content being viewed by others
References
Hirabayashi, A., Sakairi, M., Koizumi, H.: Sonic spray ionization method for atmospheric pressure ionization mass spectrometry. Anal. Chem. 66, 4557–4559 (1994)
Hirabayashi, A., Sakairi, M., Koizumi, H.: Sonic spray mass spectrometry. Anal. Chem. 67, 2878–2882 (1995)
Takats, Z., Nanita, S.C., Cooks, R.G., Schlosser, G., Vekey, K.: Amino acid clusters formed by sonic spray ionization. Anal. Chem. 75, 1514–1523 (2003)
Haddad, R., Sparrapan, R., Eberlin, M.N.: Desorption sonic spray ionization for (high) voltage-free ambient mass spectrometry. Rapid Commun. Mass Spectrom. 20, 2901–2905 (2006)
Haddad, R., Milagre, H.M.S., Catharino, R.R., Eberlin, M.N.: Easy ambient sonic-spray ionization mass spectrometry combined with thin-layer chromatography. Anal. Chem. 80, 2744–2750 (2008)
Santos, V.G., Regiani, T., Dias, F.F.G., Romão, W., Jara, J.L.P., Klitzke, C.F., Coelho, F., Eberlin, M.N.: Venturi easy ambient sonic-spray ionization. Anal. Chem. 83, 1375–1380 (2011)
Schwab, N.V., Porcari, A.M., Coelho, M.B., Schmidt, E.M., Jara, J.L., Visentainer, J.V., Eberlin, M.N.: Easy dual-mode ambient mass spectrometry with Venturi self-pumping, canned air, disposable parts, and voltage-free sonic-spray ionization. Analyst 137, 2537–2540 (2012)
Alberici, R.M., Simas, R.C., De Souza, V., De Sá, G.F., Daroda, R.J., Eberlin, M.N.: Analysis of fuels via easy ambient sonic-spray ionization mass spectrometry. Anal. Chim. Acta 659, 15–22 (2010)
Corilo, Y.E., Vaz, B.G., Simas, R.C., Nascimento, H.D.L., Klitzke, C.F., Pereira, R.C.L., Bastos, W.L., Santos Neto, E.V., Rodgers, R.P., Eberlin, M.N.: Petroleomics by EASI(+/−) FT-ICR MS. Anal. Chem. 82, 3990–3996 (2010)
Sawaya, A.C.H.F., Abdelnur, P.V., Eberlin, M.N., Kumazawa, S., Ahn, M.-R., Bang, K.-S., Nagaraja, N., Bankova, V.S., Afrouzan, H.: Fingerprinting of propolis by easy ambient sonic-spray ionization mass spectrometry. Talanta 81, 100–108 (2010)
Dams, R., Benijts, T., Günther, W., Lambert, W., De Leenheer, A.: Sonic spray ionization technology: performance study and application to a LC/MS analysis on a monolithic silica column for heroin impurity profiling. Anal. Chem. 74, 3206–3212 (2002)
Björkman, H.T., Edlund, P.-O., Jacobsson, S.P.: Sonic spray ionization interface for liquid chromatography-mass spectrometry. Anal. Chim. Acta 468, 263–274 (2002)
Van Berkel, G.J., Asano, K.G., Kertesz, V.: Enhanced study and control of analyte oxidation in electrospray using a thin-channel, planar electrode emitter. Anal. Chem. 74, 5047–5056 (2002)
Chen, M., Cook, K.D.: Oxidation artifacts in the electrospray mass spectrometry of Aβ peptide. Anal. Chem. 79, 2031–2036 (2007)
Boys, B.L., Kuprowski, M.C., Noël, J.J., Konermann, L.: Protein oxidative modifications during electrospray ionization: solution phase electrochemistry or corona discharge-induced radical attack? Anal. Chem. 81, 4027–4034 (2009)
Plattner, S., Erb, R., Chervet, J.-P., Oberacher, H.: Ascorbic acid for homogenous redox buffering in electrospray ionization-mass spectrometry. Anal. Bioanal. Chem. 404, 1571–1579 (2012)
Available at: www.Meinhard.com Meinhard. Accessed January 24 (2013)
Paredes, E., Bosque, J., Mermet, J.M., Todolí, J.L.: Influence of nebulizer design and aerosol impact bead on analytical sensitivities of inductively coupled plasma mass spectrometry. Spectrochim. Acta B 65, 908–917 (2010)
Moini, M., Jones, B.L., Rogers, R.M., Jiang, L.: Sodium trifluoroacetate as a tune/calibration the mass range of 100–4000 Da. J. Am. Soc. Mass Spectrom. 9, 977–980 (1998)
Zilch, L.W., Maze, J.T., Smith, J.W., Ewing, G.E., Jarrold, M.F.: Charge separation in the aerodynamic breakup of micrometer-sized water droplets. J. Phys. Chem. A 112, 13352–13363 (2008)
Valaskovic, G.A., Kelleher, N.L., Little, D.P., Aaserud, D.J., McLafferty, F.W.: Attomole-sensitivity electrospray source for large-molecule mass spectrometry. Anal. Chem. 67, 3802–3805 (1995)
Wahl, J.H., Gale, D.C., Smith, R.D.: Sheathless capillary electrophoresis-electrospray ionization mass spectrometry using 10 μm i.d. capillaries: analyses of tryptic digests of cytochrome c. J. Chromatogr. A 659, 217–222 (1994)
Sterling, H.J., Prell, J.S., Cassou, C.A., Williams, E.R.: Protein conformation and supercharging with DMSO from aqueous solution. J. Am. Soc. Mass Spectrom. 22, 1178–1186 (2011)
Sopasis, G.J., Canaj, A.B., Philippidis, A., Siczek, M., Lis, T., O’Brien, J.R., Antonakis, M.M., Pergantis, S.A., Milios, C.J.: Heptanuclear heterometallic [Cu6Ln] clusters: trapping lanthanides into copper cages with artificial amino acids. Inorg. Chem. 51, 5911–5918 (2012)
Riccio, M.F., Saraiva, S.A., Marques, L.A., Alberici, R., Haddad, R., Moller, J.C., Eberlin, M.N., Catharino, R.R.: Easy mass spectrometry for metabolomics and quality control of vegetable and animal fats. Eur. J. Lipid Sci. Technol. 112, 434–438 (2010)
Afton, S., Kubachka, K., Catron, B., Caruso, J.A.: Simultaneous characterization of selenium and arsenic analytes via ion-pairing reversed phase chromatography with inductively coupled plasma and electrospray ionization ion trap mass spectrometry for detection applications to river water, plant extract and urine matrices. J. Chromatogr. A 1208, 156–163 (2008)
Hannis, J.C., Muddiman, D.C.: A dual electrospray ionization source combined with hexapole accumulation to achieve high mass accuracy of biopolymers mass spectrometry. J. Am. Soc. Mass Spectrom. 11, 876–883 (2000)
Chambers, A.G., Ramsey, J.M.: Microfluidic dual emitter electrospray ionization source for accurate mass measurements. Anal. Chem. 84, 1446–1451 (2012)
Jiang, L., Moini, M.: Development of multi-ESI-sprayer, multi-atmospheric-pressure-inlet mass spectrometry and its application to accurate mass measurement using time-of-flight mass spectrometry. Anal. Chem. 72, 20–24 (2000)
Acknowledgments
The authors thank Meinhard and Elemental Scientific for providing nebulizers for this project.
Author information
Authors and Affiliations
Corresponding author
Electronic Supplementary Material
Below is the link to the electronic supplementary material.
ESM 1
(DOCX 8325 kb)
Rights and permissions
About this article
Cite this article
Antonakis, M.M., Tsirigotaki, A., Kanaki, K. et al. Bipolar Mass Spectrometry of Labile Coordination Complexes, Redox Active Inorganic Compounds, and Proteins Using a Glass Nebulizer for Sonic-Spray Ionization. J. Am. Soc. Mass Spectrom. 24, 1250–1259 (2013). https://doi.org/10.1007/s13361-013-0668-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13361-013-0668-z