Abstract
Medical technology has improved remarkably in the field of health monitoring over the past few decades, becoming more sophisticated and less invasive as the years progress. Now, non-contact measurement of respiration and heartbeat with microwave Doppler radar phase modulation, offers an attractive alternative to commonly prescribed chest strap monitors. To monitor the vital signs an unmodulated radio frequency signal is transmitted toward the human body, where it is phase-modulated by the periodic physiological movement and reflected back to the receiver. The radar receiver captures the reflected signal and demodulates it to extract the vital sign signal components. The reflected signal from the body depends on the radar cross section (RCS) of body. In this paper the RCS of human body is measured in the X-band (8–12 GHz). There are several advantages to a noncontact measurement method: physically, it neither confines nor inhibits the subject and does not cause discomfort or skin irritation as electrodes and straps do. By measuring heartbeats, this technology can also be used to detect a person’s presence, search-and-rescue for earthquake or fire victims and border patrol. It has also attracted the interest of organizations requiring high security, such as see-through- wall radar and airport security monitoring.
Similar content being viewed by others
References
Lin JC (1975) Noninvasive microwave measurement of respiration. Proc IEEE 63(10):1530
Chen KM, Misra D, Wang H, Chuang HR, Postow E (1986) An X-band microwave life-detection system. In: IEEE transactions on biomedical engineering, vol BME-33, no 7, pp 697–701
Aggelopoulos E, Karabetsos E, Uzunoglu N, Constantinou P (1995) Microwave system for the detection of trapped human beings. In: Industrial electronics, 1995. ISIE ‘95, proceedings of the IEEE international symposium on, Athens, 1995, vol 1, pp 187–192
Chen K-M, Huang Y, Zhang J, Norman A (2000) Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier. IEEE Trans Biomed Eng 47(1):105–114
Lohman B, Boric-Lubecke O, Lubecke VM, Ong PW, Sondhi MM (2001) A digital signal processor for Doppler radar sensing of vital signs. Engineering in medicine and biology society, 2001. In: Proceedings of the 23rd annual international conference of the IEEE, 2001, vol 4, pp 3359–3362
Droitcour AD, Boric-Lubecke O, Lubecke VM, Lin J, Kovacs GTA (2004) Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring. IEEE Trans Microw Theory Tech 52(3):838–848
Xiao Y, Lin J, Boric-Lubecke O, Lubecke M (2006) Frequency-tuning technique for remote detection of heartbeat and respiration using low-power double-sideband transmission in the ka-band. IEEE Trans Microw Theory Tech 54(5):2023–2032
Xiao Y, Li C, Lin J (2007) A portable noncontact heartbeat and respiration monitoring system using 5-GHz radar. IEEE Sens J 7(7):1042–1043
Li C, Lin J (2008) Complex signal demodulation and random body movement cancellation techniques for non-contact vital sign detection. In: Microwave symposium digest, 2008 IEEE MTT-S international, Atlanta, GA, 2008, pp 567–570
Park BK, Boric-Lubecke O, Lubecke VM (2007) Arctangent demodulation with DC offset compensation in quadrature Doppler radar receiver systems. IEEE Trans Microw Theory Tech 55(5):1073–1079
Li C, Lin J (2007) Optimal carrier frequency of non-contact vital sign detectors. In: 2007 IEEE radio and wireless symposium, Long Beach, CA, 2007, pp 281–284
Gu C, Li C, Lin J, Long J, Huangfu J, Ran L (2010) Instrument-based noncontact Doppler radar vital sign detection system using heterodyne digital quadrature demodulation architecture. IEEE Trans Instrum Meas 59(6):1580–1588
Chioukh L, Boutayeb H, Deslandes D, Wu K (2010) Multi-frequency radar systems for monitoring vital signs. In: 2010 Asia-Pacific microwave conference, Yokohama, 2010, pp 1669–1672
Iyer B, Garg M, Pathak NP, Ghosh D (2013) Concurrent dual-band RF system for human respiration rate and heartbeat detection. Information and communication technologies (ICT), 2013 IEEE conference on, JeJu Island, 2013, pp 563–567
Iyer B, Kumar A, Pathak NP, Ghosh D (2013) Concurrent multi-band RF system for search and rescue of human life during natural calamities. In: IEEE MTT-S international microwave and RF conference, New Delhi, 2013, pp 1–4
Zhang Y et al (2015) An interference suppression technique for life detection using 5.75- and 35-GHz dual-frequency continuous-wave radar. IEEE Geosci Remote Sens Lett 12(3):482–486
Tomii S, Ohtsuki T (2015) Heartbeat detection by using Doppler radar with wavelet transform based on scale factor learning. In: 2015 IEEE international conference on communications (ICC), London, 2015, pp 483–488
An YJ, Yun GH, Yook JG (2016) Sensitivity enhanced vital sign detection based on antenna reflection coefficient variation. IEEE Trans Biomed Circuits Syst 10(2):319–327
Park BK, Boric-Lubecke O, Lubecke VM (2007) Arctangent demodulation with DC offset compensation in quadrature Doppler radar receiver systems. IEEE Trans Microw Theory Tech 55(5):1073–1079
Li C, Lin J (2008) Complex signal demodulation and random body movement cancellation techniques for non-contact vital sign detection. In: Microwave symposium digest, 2008 IEEE MTT-S international, Atlanta, GA, 2008, pp 567–570
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Dalal, H., Basu, A. & Abegaonkar, M.P. Remote sensing of vital sign of human body with radio frequency. CSIT 5, 161–166 (2017). https://doi.org/10.1007/s40012-016-0154-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40012-016-0154-4