Abstract
A study is presented of the factors affecting the calibration of the mass scale in time-of-flight secondary ion mass spectrometry (TOF-SIMS). At the present time, TOF-SIMS analysts using local calibration procedures achieve a rather poor relative mass accuracy of only 150 ppm for large molecules (647 u) whereas for smaller fragments of <200 u this figure only improves to 60 ppm. The instrumental stability is 1 ppm and better than 10 ppm is necessary for unique identification of species. The above experimental uncertainty can lead to unnecessary confusion where peaks are wrongly identified or peaks are ambiguously assigned. Here we study, in detail, the instrumental parameters of a popular single stage reflection TOF-SIMS instrument with ion trajectory calculations using SIMION. The effect of the ion kinetic energy, emission angle, and other instrumental operating parameters on the measured peak position are determined. This shows clearly why molecular and atomic ions have different relative peak positions and the need for an aperture to restrict ions at large emission angles. These data provide the basis for a coherent procedure for optimizing the settings for accurate mass calibration and rules by which calibrations for inorganics and organics may be incorporated. This leads to a new generic set of ions for mass calibration that improves the mass accuracy in our interlaboratory study by a factor of 5. A calibration protocol is developed, which gives a relative mass accuracy of better than 10 ppm for masses up to 140 u. The effects of extrapolation beyond the calibration range are discussed and a recommended procedure is given to ensure that accurate mass is achieved within a selectable uncertainty for large molecules. Additionally, we can alternatively operate our instrument in a regime with good energy discrimination (i.e., poor energy compensation) to study the fragmented energies of molecules. This leads to data that support previous concepts developed in G-SIMS.
Article PDF
Similar content being viewed by others
References
Gilmore, I. S.; Seah, M. P.; Green, F. M. Static TOF-SIMS—A VAMAS Interlaboratory Study. Part I. Repeatability and Reproducibility of Spectra. Surf. Interface Anal. 2005, 37, 651–672.
International Standards Organization www.iso.org.
Gilmore,, I. S., Seah,, M. P. VAMAS 2002: Static TOF SIMS Interlaboratory Study—Protocol for Analysis. NPL Report 2001, COAM(A)6.
Niehuis, E.; Van Velzen, P. N. T.; Lub, J.; Heller, T.; Benninghoven, A. High Mass Resolution Time-of-Flight Secondary Ion Mass Spectrometry: Application to Peak Assignments. Surf. Interface Anal. 1989, 14, 135–142.
Niehuis, E. Exact Mass Determination Using TOF-SIMS. In SIMS VII; John Wiley and Sons, Chichester, 1990; pp 299–304.
Reichlmaier, S.; Hammond, J. S.; Hearn, M. J.; Briggs, D. Analysis of Polymer Surfaces by SIMS 17. An Assessment of the Accuracy of the Mass Assignment Using a High Mass Resolution TOF-SIMS Instrument. Surf. Interface Anal. 1994, 21, 739–746.
Bristow, A. W. T.; Webb, K. S. Intercomparison Study on Accurate Mass Measurement of Small Molecules in Mass Spectrometry. J. Am. Soc. Mass Spectrom. 2003, 14, 1086–1098.
Schwieters, J.; Cramer, H. G.; Heller, T.; Jürgens, U.; Niehuis, E.; Zehnphenning, J.; Benninghoven, A. High Mass Resolution Surface Imaging with a Time-of-Flight Secondary Ion Mass Spectroscopy Scanning Microprobe. J. Vac. Sci. Technol. A 1991, 9, 2864–2871.
Dahl,, D. A. SIMION 3D, version 7.0; Idaho National Engineering and Environmental Laboratory.
Sigmund, P. Sputtering by Ion Bombardment: Theoretical Concepts. In Sputtering by Particle Bombardment I. Behrisch, R., Ed.; Springer: Berlin, 1981, p 37.
Thompson, M. W. The Energy Spectrum of Ejected Atoms during the High Energy Sputtering of Gold. Philos. Mag. 1968, 18, 377–414.
Urbassek, H. M. Sputtering of Molecules. NIMB 1987, 18, 587–595.
Hoogerbrugge, R.; Kistemaker, P. G. Kinetic and Internal Energy Distributions of Sputtered Molecules and Clusters. NIMB 1987, 18, 600–604.
Haring, R. A.; Roosendaal, H. E.; Zalm, P. C. On the energy and angular distribution of sputtered polyatomic molecules. NIMB 1987, 28, 205–213.
Wittmaack, K. Secondary-Ion Emission from Silicon Bombarded with Atomic and Molecular Noble-Gas Ions. Surf. Sci. 1979, 90, 557–563.
Delcorte, A.; Bertrand, P. Kinetic Energy Distributions of Secondary Molecular Ions from Thin Organic Films Under Ion Bombardment. NIMB 1996, 115, 246–250.
Delcorte, A.; Bertrand, P. Energy Distributions of Hydrocarbon Secondary Ions from Thin Organic Films Under keV Ion Bombardment: Correlation Between Kinetic and Formation Energy of Ions Sputtered from Tricosenoic Acid. NIMB 1996, 117, 235–242.
Delcorte, A.; Vanden Eynde, X.; Bertrand, P.; Vickerman, J. C.; Garrison, B. J. Kiloelectron Volt Particle-Induced Emission and Fragmentation of Polystyrene Molecules Adsorbed on Silver: Insights from Molecular Dynamics. J. Phys. Chem. B 2000, 104, 2673–2691.
Delcorte, A. Fundamental Aspects of Organic SIMS. In TOF-SIMS Surface Analysis by Mass Spectrometry, Vickerman, J. C.; Briggs, D., Eds.; Surface Spectrum: UK, 2001; pp 161–195.
Snowdon, K. J.; Haring, R. A. Diatomic Molecule Sputtering in the Independent Binary Collision Approximation. NIMB 1987, 18, 596–599.
ISO 22048:2004—Surface Chemical Analysis—Information format for Static SIMS.
Gilmore, I. S.; Seah, M. P. Static SIMS: Towards Unfragmented Mass Spectra—The G-SIMS Procedure. Appl. Surf. Sci. 2000, 161, 465–480.
Gilmore, I. S.; Seah, M. P. G-SIMS of Crystallizable Organics. Appl. Surf. Sci. 2003, 203/204, 551–555.
Gilmore, I. S.; Seah, M. P. Organic Molecule Characterization—G-SIMS. Appl. Surf. Sci. 2004, 231/232, 224–229.
Seah, M. P.; Gilmore, I. S.; Spencer, S. J. X. P. S. Binding Energy Calibration of Electron Spectrometers 4—Assessment of Effects for Different X-ray Sources, Analyzer Resolutions, Angles of Emission, and of the Overall Uncertainties. Surf. Interface Anal. 1998, 26, 617–641.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published online February 28, 2006
Rights and permissions
About this article
Cite this article
Green, F.M., Gilmore, I.S. & Seah, M.P. TOF-SIMS: Accurate mass scale calibration. The official journal of The American Society for Mass Spectrometry 17, 514–523 (2006). https://doi.org/10.1016/j.jasms.2005.12.005
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1016/j.jasms.2005.12.005