Skip to main content
Log in

An Evaporation-Based Disposable Micropump Concept for Continuous Monitoring Applications

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

An Erratum to this article was published on 01 July 2002

Abstract

An inexpensive and simple pumping principle is described that is capable of delivering both small and constant flow rates (10–1,000 nl/min) over a longer period of time (days to weeks). The concept is based on controlled evaporation of a liquid through a membrane into a gas space containing a sorption agent. As long as the sorption agent keeps the vapor pressure in the gas phase below saturation, fluid evaporated from the membrane is replaced by capillary forces inducing flow from a reservoir. In a feasibility study, a total volume of 300 μl of Ringer's solution has been continuously pumped over a period of six days, resulting in an constant average flow rate of 35 nl/min (590 pl/s). The maximum liquid volume transported is limited by sorption capacity and amount of the sorption agent. Low fabrication costs, high reliability (no moving parts), the suitability for integration into planar system architectures and the lack of a special external energy source besides an environment of regulated temperature are important features of the concept, in particular with regard to its potential application in continuous patient monitoring. Truly continuous flow can be achieved in contrast to many other pump mechanisms leading to discontinuous, pulse-type flow. A challenge for a broader range of applications is the inherent temperature dependence of the flow rate. In its current version, the pump can only be used in a suction-mode.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • H. Andersson, W. Vander Wijngaart, P. Nilsson, P. Enoksson, and G. Stemme, Sensors & Actuators B 72, 259-265 (2001).

    Google Scholar 

  • P. Bergveld, Biomedical Microdevices 2, 185-195 (2000).

    Google Scholar 

  • S. Böhm, W. Olthuis, and P. Bergveld, Biomedical Microdevices 1, 121-130 (2000).

    Google Scholar 

  • T.A. Desai, D.J. Hansford, L. Kulinsky, A.H. Nashat, G. Rasi, J. Tu, Y. Wang, M. Ahang, and M. Ferrari, Biomedical Microdevices 2, 11-40 (1999).

    Google Scholar 

  • C.S. Effenhauser, Topics in Current Chemistry 194, 51-82 (1998).

    Google Scholar 

  • M. Elwenspoek, T.S.J. Lammerink, R. Miyake, and J.H.J. Fluitman, Journal of Micromechanics Micro-engineering 4, 227-245 (1994).

    Google Scholar 

  • L.M. Hullegie, H.L. Lutgers, R.P.F. Dullaart, W.J. Sluiter, K.J. Wientjes, A.J.M. Schoonen, and K. Hoogenberg, The Netherlands Journal of Medicine 57, 13-19 (2000).

    Google Scholar 

  • W.A. Kaptein, J.C. Zwaagstra, K. Venema, and J. Korf, Analytical Chemistry 70, 4696-4700 (1998).

    Google Scholar 

  • J.P. Kutter, Trends in Analytical Chemistry 19, 352-363 (2000).

    Google Scholar 

  • H.L. Lutgers, L.M. Hullegie, K. Hoogenberg, W.J. Sluiter, R.P.F. Dullaart, K.J. Wientjes, and A.J.M. Schoonen, The Netherlands Journal of Medicine 57, 7-12 (2000).

    Google Scholar 

  • N.-T. Nguyen and X. Huang, Sensors & Actuators A 88, 104-111 (2001).

    Google Scholar 

  • J. Perdomo, H. Hinkers, C. Sundermeier, W. Seifert, O. Martinez Morell, and M. Knoll, Biosensors & Bioelectronics 15, 515-522 (2000).

    Google Scholar 

  • R.F. Probstein, “Physicochemical Hydrodynamics”, 2nd edn, Wiley, New York, 1994.

    Google Scholar 

  • S. Shoji, Topics in Current Chemistry 194, 163-188 (1998).

    Google Scholar 

  • F. Sternberg, C. Meyerhoff, F. Mennel, F. Bischoff, and E.F. Pfeiffer, Diabetes Care 18, 1266-1269 (1995).

    Google Scholar 

  • L. Taiz and E. Zeiger, “Plant Physiology”, 2nd edn, Whitaker, 1998.

  • T. Tamura, K. Koseki, T. Sumino, M. Ogawa, T. Togawa, and K. Tsuchiya, Frontiers in Medical and Biological Engineering 10, 147-156 (2000).

    Google Scholar 

  • M.A. Unger, H.-P. Chou, T. Thorsen, A. Scherer, and S.R. Quake, Science 288, 113-116 (2000).

    Google Scholar 

  • T. Vering, S. Adam, H. Drewer, C. Dumschat, R. Steinkuhl, A. Schulee, E.M. Siegel, and M. Knoll, Analyst 123, 1605-1609 (1998).

    Google Scholar 

  • A. Wego and L. Pagel, Sensors & Actuators A 88, 220-226 (2001).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Carlo S. Effenhauser.

Additional information

An erratum to this article can be found at http://dx.doi.org/10.1023/A:1016068325597

Rights and permissions

Reprints and permissions

About this article

Cite this article

Effenhauser, C.S., Harttig, H. & Krämer, P. An Evaporation-Based Disposable Micropump Concept for Continuous Monitoring Applications. Biomedical Microdevices 4, 27–32 (2002). https://doi.org/10.1023/A:1014215728074

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1014215728074

Navigation