Abstract

A high-performance liquid chromatographic method of reversed-phase with a post-column iodineazide reaction has been developed and validated for the determination of thioguanine. Isocratic elution was performed on a column of C18 using acetonitrile- water-sodium azide solution (1.5%; pH 6.5) 16: 34: 50 (v/v/v) as a mobile phase with flow-rate of 0.5 mL/min. Monitoring of unreacted iodine in post-column iodine-azide reaction induced by thioguanine resulted in its detection at 350 nm. The method applied to thioguanine was linear within the scope of values 8–100 nM (r 2 > 0.9988). The relative standard deviation (RSD < 4.2%) and the recovery (>96%) prove that the intra-day precision and the accuracy were satisfactory. The lower limits of detection (LLD) and quantification (LLQ) of thioguanine were established at the levels of 6 and 8 nM, respectively. The elaborated method was validated and applied to thioguanine determination in tablets.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Lippincott, P.A., Cancer Chemotherapy and Biotherapy, Philadelphia: Williams & Wilkins, 2001.

    Google Scholar 

  2. Halbert, M.K. and Baldwin, R.P., Anal. Chim. Acta, 1986, vol. 187, p. 89.

    Article  CAS  Google Scholar 

  3. Andrew, P.A., Egorin, M.J., May, M.E., and Bachur, N.R., J. Chromatogr., 1982, vol. 227, no. 1, p. 83.

    Article  Google Scholar 

  4. Su, Y., Hon, Y.Y., Chu, Y.Q., van de Poll, M.E.C., and Relling, M.V., J. Chromatogr. B, 1999, vol. 732, no. 2, p. 459.

    Article  CAS  Google Scholar 

  5. van Baal, J.M., van Leeuwen, M.B., Schouten, T.J., and de Abreu, R.A., J. Chromatogr., 1984, vol. 336, no. 1, p. 422.

    Article  Google Scholar 

  6. Erb, N., Haverland, U., Harms, D.O., Escherich, G., and Janka-Schaub, G., J. Chromatogr. B, 2003, vol. 796, no. 1, p. 87.

    Article  CAS  Google Scholar 

  7. Dervieux, T. and Boulieu, R., Clin. Chem., 1998, vol. 44, no. 3, p. 551.

    CAS  Google Scholar 

  8. Boulieu, R. and Lenoir, A., J. Chromatogr. B, 1995, vol. 665, no. 1, p. 213.

    Article  CAS  Google Scholar 

  9. Rudy, J.L., Argyle, J.C., Winck, N., and van Dreal, P., Ann. Clin. Biochem., 1988, vol. 25, no. 5, p. 504.

    CAS  Google Scholar 

  10. Miura, Y., Fukasawa, K., and Koh, T., J. Chromatogr. A, 1998, vol. 804, no. 1–2, p. 143.

    Article  CAS  Google Scholar 

  11. Miura, Y. and Watanabe, M., J. Chromatogr. A, 2001, vol. 920, no. 1–2, p. 163.

    Article  CAS  Google Scholar 

  12. Kurzawa, J., Chem. Anal. (Warsaw), 1987, vol. 32, no. 6, p. 875.

    CAS  Google Scholar 

  13. Kurzawa, J., Chem. Anal. (Warsaw), 1988, vol. 33, no. 5, p. 771.

    CAS  Google Scholar 

  14. Ciesielski, W., Chem. Anal. (Warsaw), 1991, vol. 36, no. 3, p. 613.

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

The article is published in the original.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zakrzewski, R. Development and validation of a reversed-phase HPLC method with post-column iodine-azide reaction for the determination of thioguanine. J Anal Chem 64, 1235–1241 (2009). https://doi.org/10.1134/S1061934809120065

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1061934809120065

Keywords

Navigation