Abstract
The long-term stability of a 640x512 InSb focal plane array (FPA) with a pitch of 15 μm combined with a Stirling cooler and an interface block has been investigated.The dependences of the FPA correctability index on the operation time after a two-point correction of the irregularity have been obtained. The FPAs with two different circuits of the readout LSI cells that differ in the integration capacitance and transmission coefficients are considered. It has been found that, for the InSb FPA, the long-term stability is as high as several hours, which ensures continuous operation of the array in thermal imaging systems without additional calibrations.
Similar content being viewed by others
References
T. Svensson, Proc. SPIE 8706, 04-1 (2013).
D. L. Baliev, K. O. Boltar, P. V. Vlasov, et al., Prikl. Fiz., No. 2, 41 (2014).
K. O. Boltar, L. V. Kiseleva, A. A. Lopukhin, and A. V. Savostin, “Methods for production of focal plane arrays (variants),” RF Patent No. 2460174, Byull. Izobret., No. 24 (2012).
W. Gross, T. Hierl, and M. Schulz, Opt. Eng. 38, 862 (1999).
V. N. Solyakov and M. V. Kortikov, Prikl. Fiz., No. 1, 58 (2010).
K. O. Boltar, P. V. Vlasov, A. A. Lopukhin, and N. G. Mansvetov, Prikl. Fiz., No. 3, 67 (2014).
Z. N. Efimova, I. V. Efimov, N. G. Mansvetov, et al., “IR focal plane array with cooled diaphragm and the diaphragm manufacturing method,” RF Patent No. 2571171, Byull. Izobret., No. 36 (2015).
P.-Y. Delaunay, B. Z. Nosho, A. R. Gurga, et al., Proc. SPIE 10177, 0T-1 (2017).
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © P.V. Vlasov, 2016, published in Prikladnaya Fizika, 2016, No. 5, pp. 38–41.
Rights and permissions
About this article
Cite this article
Vlasov, P.V. Long-Term Stability of a 640 × 512 InSb Focal Plane Array with a Pitch of 15 μm. J. Commun. Technol. Electron. 63, 285–288 (2018). https://doi.org/10.1134/S1064226918030208
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1064226918030208