Abstract
A numerical investigation was conducted to study the role of rebar mesh on the electrical resistivity measurements of concrete using the Wenner probe technique. The effects of rebar spacing, cover thickness, the location of the Wenner probe with respect to the rebar mesh, and slab thickness were investigated. The results revealed that current guidelines for taking resistivity measurements over rebar mesh do not necessarily provide the most accurate results. As much as 30 % increase in accuracy can be achieved just by selecting appropriate orientation or location for the Wenner probe. Having the probe placed parallel to the top rebars midway between both top and bottom bars was found to be the most suitable arrangement to minimize the rebar mesh interference on the electrical resistivity measurements.
Similar content being viewed by others
Abbreviations
- a :
-
Electrode spacing of Wenner probe (mm)
- S :
-
Rebar spacing (mm)
- T :
-
Concrete cover thickness (mm)
- Γ i :
-
Domain boundary i
- ρ :
-
Electrical resistivity (Ω m)
- ϕ :
-
Rebar diameter (mm)
- Ω i :
-
Subdomain i
References
AASHTO TP 095-11-UL (2011) Standard method of test for surface resistivity indication of Concrete’s ability to resist chloride ion penetration. Washington, DC: American Association of State Highway and Transportation Officials
Angst U M, Elsener B (2013). On the Applicability of the Wenner Method for Resistivity Measurements of Concrete. ACI Mater J
ASTM WK37880 (2012). Standard Test Method for Measuring the Surface Resistivity of Hardened Concrete Cylinders or Cores using the Wenner Four-Electrode Method (draft).West Conshohocken, PA: ASTM International. http://www.astm.org/DATABASE.CART/WORKITEMS/WK37880.htm
Butler S, Sinha G (2012) Forward modeling of applied geophysics methods using comsol and comparison with analytical and laboratory analog models. Comput Geosci 42:168–176
CAN/CSA A23.3 (Eds.) (2004) Design of concrete structures (2010th ed.). Toronto, ON: Canadian Standards Association
CAN/CSA A23.2 (2009). Concrete materials and methods of concrete construction/Test methods and standard practices for concrete. Toronto, ON: Canadian Standards Association
Ewins AJ (1990) Resistivity measurements in concrete. Br J Nondestruct Test 32(3):120–126
Feliu S, Andrade C, Gonzalez J, Alonso C (1996) A new method for in situ measurement of electrical resistivity of reinforced concrete. Mater Struct 29(6):362–365
FM 5-578 (2004) Florida method of test for concrete resistivity as an electrical indicator of its permeability. Department of Transportation Florida, Tallahassee
Gowers K, Millard S (1999) Measurement of concrete resistivity for assessment of corrosion severity of steel using Wenner technique. ACI Mater J 96(5):536–541
Hamilton HR, Boyd A, Vivas E, Bergin M (2007) Permeability of concrete—comparison of conductivity and diffusion methods (No. 00026899). University of Florida, Gainesville
Kessler RJ, Powers RG, Paredes MA (2005) Resistivity measurements of water saturated concrete as an indicator of permeability. In: Proceeding of corrosion 2005 conference. NACE International, Houston
Millard S (1991) Reinforced concrete resistivity measurement techniques. In: ICE Proceedings, vol 91(1), pp 71–88
Morris W, Moreno E, Sagüés A (1996) Practical evaluation of resistivity of concrete in test cylinders using a Wenner array probe. Cem Concr Res 26(12):1779–1787
MTO LS-444 (2013) Method of test for determination of electrical resistivity of concrete. Ministry of Transportation Ontario, Toronto
Gucunski N, Imani A, Romero F, Nazarian, S, Yuan D, Wiggenhauser H, Kutrubes D (2013) Nondestructive testing to identify concrete bridge deck deterioration (No. S2-R06A-RR-1). Transportation Research Board, Washington
Persuel-Moreno F, Liu Y, Paredes M (2009) Understanding the effect of rebar presence and/or multilayered concrete resistivity on the apparent surface resistivity measured via the four point Wenner method. In: Proceeding of corrosion 2009 conference & expo. NACE International, Atlanta
Polder R, Andrade C, Elsener B, Vennesland Ø, Gulikers J, Weidert R, Raupach M (2000) Test methods for on site measurement of resistivity of concrete. Mater Struct 33(10):603–611
Presuel-Moreno F, Liu Y, Wu YY (2013) Numerical modeling of the effects of rebar presence and/or multilayered concrete resistivity on the apparent resistivity measured via the Wenner method. Constr Build Mater 48:16–25
RILEM TC 154-EMC (2000) Electrochemical techniques for measuring metallic corrosion: test methods for on-site measurement of resistivity of concrete. Mater Struct 33(234):603–611
Salehi M (2013) Numerical investigation of the effects of cracking and embedded reinforcement on surface concrete resistivity measurements using Wenner probe. Dissertation, Carleton University
Sengul O, Gjorv OE (2008) Electrical resistivity measurements for quality control during concrete construction. ACI Mater J 105(6):541–547
Sengul O, Gjorv OE (2009) Effect of embedded steel on electrical resistivity measurements on concrete structures. ACI Mater J 106(1):11–18
Telford WM, Geldart LP, Sheriff RE (1990) Applied geophysics, 2nd edn. Cambridge University Press, New York
Wei X, Li Z (2006) Early hydration process of Portland cement paste by electrical measurement. J Mater Civ Eng 18(1):99–105
Weydert R, Gehlen C (1999) Electrolytic resistivity of cover concrete: relevance, measurement and interpretation. In: Lacasse MA, Vanier DJ (eds) Proceeding of durability of building materials and components, vol 1. NRC Research Press, Vancouver, pp 409–419
Xiao L, Li Z (2008) Early-age hydration of fresh concrete monitored by non-contact electrical resistivity measurement. Cem Concr Res 38(3):312–319
Zienkiewicz OC, Emson C, Bettess P (1983) A novel boundary infinite element. Int J Numer Methods Eng 19(3):393–404
Acknowledgments
This study was conducted using the financial support from Natural Science and Engineering Research Council of Canada. Critical feedback and support provided by technical staff of Giatec Scientific Inc. are also acknowledged.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Salehi, M., Ghods, P. & Burkan Isgor, O. Numerical investigation of the role of embedded reinforcement mesh on electrical resistivity measurements of concrete using the Wenner probe technique. Mater Struct 49, 301–316 (2016). https://doi.org/10.1617/s11527-014-0498-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1617/s11527-014-0498-x