Abstract
X-ray computed tomography (CT) images obtained with a polychromatic X-ray source were simulated by computer for homogeneous solutions and suspensions containing a heavy element. When the K-edge of the element was near the peak energy of the polychromatic X-ray spectrum, the degree of beam hardening in the simulated CT image strongly depended on the atomic number and molar concentration of the heavy element. We analyzed the beam hardening of a single measured CT image of a CeCl3 aqueous solution sample, and successfully estimated the atomic number and the molar concentration of Ce simultaneously within a certain error. This single-shot, or single-energy (as opposed to dual-energy), CT method permits quick, nondestructive screening of a hazardous heavy element in a solution or suspension confined in a container.
Similar content being viewed by others
References
N. Seignez, A. Gauthier, F. Mess, C. Brunel, M. Dubois, and J. L. Potdevin, Water, Air, Soil Pollut., 2010, 209, 199.
S. Akbulut, R. Grieken, M. A. Kılıc, U. Cevik, and G. G. Rotondo, Environ. Monit. Asses., in press.
K. Wells and D. A. Bradley, Appl. Radiat. Isot., 2012, 70, 1729.
T. Nakano, Y. Nakashima, K. Nakamura, and S. Ikeda, J. Geol. Soc. Jpn., 2000, 106, 363.
R. A. Ketcham and W. D. Carlson, Comp. Geosci., 2001, 27, 381.
Y. Nakashima, Eng. Geol., 2000, 56, 11.
Y. Nakashima, J. Contam. Hydrol., 2003, 61, 147.
Y. Suzuki, K. Usami, K. Sakamoto, H. Kozaka, T. Hirano, H. Shiono, and H. Kohno, Jpn. J. Appl. Phys., 1988, 27, L461.
T. Hirano, S. Eguchi, and K. Usami, Jpn. J. Appl. Phys., 1989, 28, 135.
C. Rizescu, C. Beşliu, and A. Jipa, Nucl. Instrum. Methods Phys. Res., Sect. A, 2001, 465, 584.
S. Ikeda, T. Nakano, A. Tsuchiyama, K. Uesugi, Y. Suzuki, K. Nakamura, Y. Nakashima, and H. Yoshida, Am. Miner., 2004, 89, 1304.
T. Ohgaki, Y. Takami, H. Toda, T. Kobayashi, Y. Suzuki, K. Uesugi, K. Makii, T. Takagi, and Y. Aruga, Mater. Sci. Forum, 2007, 561 – 565, 1677.
S. L. Wellington and H. J. Vinegar, J. Petrol. Technol., 1987, 39, 885.
H. Rogasik, J. W. Crawford, O. Wendroth, I. M. Young, M. Joschko, and K. Ritz, Soil Sci. Soc. Am. J., 1999, 63, 741.
M. Van Geet, R. Swennen, and M. Wevers, Sediment. Geol., 2000, 132, 25.
M. Van Geet, R. Swennen, and M. Wevers, Comp. Geosci., 2001, 27, 1091.
K. Remeysen and R. Swennen, Int. J. Coal Geol., 2006, 67, 101.
T. R. C. Johnson, B. Krauß, M. Sedlmair, M. Grasruck, H. Bruder, D. Morhard, C. Fink, S. Weckbach, M. Lenhard, B. Schmidt, T. Flohr, M. F. Reiser, and C. R. Becker, Eur. Radiol., 2007, 17, 1510.
M. Bazalova, J.-F. Carrier, L. Beaulieu, and F. Verhaegen, Phys. Med. Biol., 2008, 53, 2439.
M. Iovea, G. Oaie, C. Ricman, G. Mateiasi, M. Neagu, S. Szobotka, and O. G. Duliu, Eng. Geol., 2009, 103, 119.
M. Iovea, M. Neagu, O. G. Duliu, G. Oaie, S. Szobotka, and G. Mateiasi, J. Nondestruct. Eval., 2011, 30, 164.
Y. Ghorbani, M. Becker, J. Petersen, S. H. Morar, A. Mainza, and J.-P. Franzidis, Miner. Eng., 2011, 24, 1249.
A. Tsuchiyama, T. Hanamoto, Y. Nakashima, and T. Nakano, J. Min. Petrol. Sci., 2000, 95, 125.
M. J. Berger, J. H. Hubbell, S. M. Seltzer, J. Chang, J. S. Coursey, R. Sukumar, D. S. Zucker, and K. Olsen, XCOM: Photon Cross Sections Database (National Institute of Standards and Technology), http://www.nist.gov/pml/data/xcom/index.cfm/.
C. Ruth and P. M. Joseph, Med. Phys., 1995, 22, 1977.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Rights and permissions
About this article
Cite this article
Nakashima, Y., Nakano, T. Nondestructive Quantitative Analysis of a Heavy Element in Solution or Suspension by Single-Shot Computed Tomography with a Polychromatic X-ray Source. ANAL. SCI. 28, 1133–1138 (2012). https://doi.org/10.2116/analsci.28.1133
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.28.1133