Abstract
Magnetic resonance (MR) thermometry is a noninvasive method for monitoring local temperature change during thermal therapy. In this study, a MR temperature analysis program was established for a laser with gold nanorods (GNRs) and high-intensity focused ultrasound (HIFU)-induced heating MR thermometry. The MR temperature map was reconstructed using the water proton resonance frequency (PRF) method. The temperature-sensitive phase difference was acquired by using complex number subtraction instead of direct phase subtraction in order to avoid another phase unwrapping process. A temperature map-analyzing program was developed and implemented in IDL (Interactive Data Language) for effective temperature monitoring. This one program was applied to two different heating devices at a clinical MR scanner. All images were acquired with the fast spoiled gradient echo (fSPGR) pulse sequence on a 3.0 T GE Discovery MR750 scanner with an 8-channel knee array coil or with a home-built small surface coil. The analyzed temperature values were confirmed by using values simultaneously measured with an optical temperature probe (R2 = 0.996). The temperature change in small samples induced by a laser or by HIFU was analyzed by using a raw data, that consisted of complex numbers. This study shows that our MR thermometry analysis program can be used for thermal therapy study with a laser or HIFU at a clinical MR scanner. It can also be applied to temperature monitoring for any other thermal therapy based on the PRF method.
Similar content being viewed by others
References
D. Germain, P. Chevallier, A. Laurent and H. Saint-Jalmes, MAGMA. 13, 47 (2001).
V. Rieke and K. B. Pauly, J. Magn. Reson. Imaging 27, 376 (2008).
B. D. de Senneville, C. Mougenot, B. Quesson, I. Dragonu, N. Grenier and C. T Moonen, Eur. Radiol. 17, 2401 (2007).
T. J. Vogl, R. Straub, S. Zangos, M. G. Mack and K. J. Eichler, Hyperthermia 20, 713 (2004).
A. Maataoui, J. Qian, M. G. Mack, R. Straub, E. Oppermann, M. F. Khan, V. Knappe and T. J. Vogl, Rofo. 177, 405 (2005).
J. Gellermann, W. Wlodarczyk, A. Feussner, H. Fahling, J. Nadobny, B. Hildebrandt, R. Felix and P. Wust, Int J Hyperthermia 21, 497 (2005).
C. Aub´e, D. Schmidt, J. Brieger, M. Schenk, T. Helmberger, C. W. Koenig, F. Schick, C. D. Claussen and P. L. Pereira, J. Vasc. Interv. Radiol. 15, 385 (2004).
K. Demura, S. Morikawa, K. Murakami, K. Sato, H. Shiomi, S. Naka, Y. Kurumi, T. Inubushi and T. Tani, J. Surg. Res. 135, 179 (2006).
K. Sato, S. Morikawa, T. Inubushi, Y. Kurumi, S. Naka, H. A. Haque, K. Demura and T. Tani, Magn. Reson. Med. Sci. 4, 89 (2005).
E. A. Stewart et al., Fertil. Steril. 85, 22 (2006).
H. Furusawa, K. Namba, S. Thomsen, F. Akiyama, A. Bendet, C. Tanaka, Y. Yasuda and H. Nakahara, J. Am. Coll. Surg. 203, 54 (2006).
R. D. Peters, E. Chan, J. Trachtenberg, S. Jothy, L. Kapusta, W. Kucharczyk and R. M. Henkelman, Magn. Reson. Med. 44, 873 (2000).
V. P. Zharov, K. E. Mercer, E. N. Galitovskaya and M.S. Smeltzer, Biophys. J. 90, 619 (2006).
W. Cai, T. Gao, H. Hong and J. Sun, Nanotechnol. Sci. Appl. 19, 17 (2008).
C. Loo, A. Lowery, N. Halas, J. West and R. Drezek, Nano. Lett. 5, 709 (2005).
L. Tong, Y. Zhao, T. B. Huff, M. N. Hans, A. Wei and J. X. Cheng, Adv. Mater. 19, 3136 (2007).
Y. Chen, S. C. Gnyawali, F. Wu, H. Liu, Y. A. Tesiram, A. Abbott, R. A. Towner and W. R. Chen. J. Biomed. Opt. 13, 044033 (2008).
T. J. Vogl, F. Huebner, N. N. Naguib, R. W. Bauer, M. G. Mack, N. E. Nour-Eldin and D. Meister. Lasers Surg. Med. 44, 257 (2012).
B. Bazrafshan, F. Hübner, P. Farshid, J. Paul, R. Hammerstingl, V. Vogel, W. Mäntele and T. J. Vogl. Future Oncol. 9, 1039 (2013).
K. Hynynen, J. Magn. Reson. Imaging. 34, 482 (2011).
S. L. Hokland, M. Pedersen, R. Salomir, B. Quesson, H. Stødkilde-Jørgensen and C. T. Moonen, IEEE Trans. Med. Imaging 25, 723 (2006).
E. A. Stewart et al., Am. J. Obstet. Gynecol. 189, 48 (2003).
L. Zhang et al., Eur. J. Radiol. 73, 396 (2010).
D. Gianfelice, A. Khiat, Y. Boulanger, M. Amara and A. Belblidia, J. Vasc. Interv. Radiol. 14, 1275 (2003).
H. Furusawa, K. Namba, H. Nakahara, C. Tanaka, Y. Yasuda, E. Hirabara, M. Imahariyama and K. Komaki, Breast Cancer 14, 55 (2007).
T. A. Leslie et al., Br. J. Radiol. 81, 564 (2008).
B. Quesson, M. Merle, M. O. Kohler, C. Mougenot, S. Roujol, B. D. de Senneville and C. T. Moonen, Med. Phys. 37, 2533 (2010).
J. Gellermann, W. Wlodarczyk, A. Feussner, H. Fahling, J. Nadobny, B. Hildebrandt, R. Felix and P. Wust. Int. J. Hyperthermia 21, 497 (2005)
N. McDannold, G. T. Clement, P. Black, F. Jolesz and K. Hynynen, Neurosurgery, 66, 323 (2010).
J. C Hindman. J. Chem. Phys. 44, 4582 (1966).
Y. Ishihara, A. Calderon, H. Watanabe, K. Okamoto, Y. Suzuki, K. Kuroda and Y. Suzuki, Magn. Reson. Med. 34, 814 (1995).
W. Wlodarczyk, R. Boroschewski, M. Hentschel, P. Wust, G. Monich and R. Felix R, J. Magn. Reson. Imaging 8, 165 (1998).
J. Yuan, C. S. Mei, L. P. Panych, N. J. McDannold and B. Madore, Quant. Imaging. Med. Surg. 2, 21 (2012).
B. Quesson, J. A. de Zwart and C. T. Moonen, J. Magn. Reson. Imaging 12, 525 (2000).
R. D. Peters. R. S. Hinks and R. M. Henkelman, Magn. Reson. Med. 40, 454 (1998).
M. A. Bernstein Handbook of MRI Pulse Sequences (Elsevier Academic press, Burlington, 2004), Chap. 13.5, p. 558.
A. H. Chung, K. Hynynen, V. Colucci, K. Oshio, H. E. Cline and F. A. Jolesz, Magn. Reson. Med. 36, 745 (1996)
M. A. Bernstein, M. Grgic, T. J. Brosnan and N. J Pelc, Magn. Reson. Med. 32, 330 (1994).
Y. Hong, E. Lee, J. Choi, S. J. Oh, S. Hamm, Y. M. Huh, D. S. Yoon, J. S. Suh and J. Yang, Journal of Nanomaterials, Article ID 825060 (2012)
E. J. Kim, D. Kim, S. Lee, D. Heo, Y. H. Lee and J. S. Suh, J. Kor. Soc. Magn. Reson. Med. 18, 52 (2014).
E. A. Barberi, J. S. Gati, B. K. Rutt and R. S. Menon, Magn. Reson. Med. 43, 284 (2000).
B. D. de Senneville, C. Mougenot and C. T. Moonen, Magn. Reson. Med. 57, 319 (2007).
A. B. Holbrook, J. M. Santos, E. Kaye, V. Rieke and K. B. Pauly, Magn. Reson. Med. 63, 365 (2010).
B. Quesson B, C. Laurent, G. Maclair, B. D. de Senneville, C. Mougenot, M. Ries, T. Carteret, A. Rullier and C. T. Moonen, NMR. Biomed. 24, 145 (2011).
N. Todd, M. Diakite, A. Payne and D. L. Parker, Magn. Reson. Med. 69, 62 (2013).
Y. Han and C. Mun, J. Magn. Reson. Imaging 34, 1231 (2011).
C. Weidensteiner, B. Quesson, B. Caire-Gana, N. Kerioui, A. Rullier, H. Trillaud and C. T. Moonen, Magn. Reson. Med. 50, 322 (2003).
A. B. Holbrook, J. M. Santos, E. Kaye, V. Rieke and K. B. Pauly, Magn. Reson. Med. 63, 365 (2010).
United State Patent, US 8368401 (2013). http://patents.com/us-8368401.html
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kim, E.J., Jeong, K., Oh, S.J. et al. MR thermometry analysis program for laser- or high-intensity focused ultrasound (HIFU)-induced heating at a clinical MR scanner. Journal of the Korean Physical Society 65, 2126–2131 (2014). https://doi.org/10.3938/jkps.65.2126
Received:
Accepted:
Published:
Issue Date: