Skip to main content

Simultaneous Estimation of PET Attenuation and Activity Images with Divided Difference Filters

  • Conference paper
Medical Imaging and Augmented Reality (MIAR 2006)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 4091))

Included in the following conference series:

  • 1228 Accesses

Abstract

For quantitative image reconstruction in positron emission tomography attenuation correction is necessary. A common technique used for attenuation correction is based on patient-specific attenuation maps reconstructed from transmission data acquired with external sources. However, the transmission process increases measurement time, costs and radiation exposure, and generates misregistration errors due to patient motion. In this paper, we propose a framework for simultaneous reconstruction of activity distribution together with the attenuation map from emission data alone. The estimation process is accomplished by solving a nonlinear stationary state space model with a divided difference filter. A Zubal digital thorax phantom data is used to demonstrate the benefits of such a reconstruction.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Barrett, H.H., Swindell, W.: Radiological Imaging: The Theory of Image Formation, Detection, and Processing. Academic Press, San Diego (1981)

    Google Scholar 

  2. Zaidi, H., Hasegawa, B.: Determination of the attenuation map in emission tomography. J. Nucl. Med. 44, 291–315 (2003)

    Google Scholar 

  3. Fessler, J.A., Ficaro, E.P., Clinthorne, N.H., Lange, K.: Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction. IEEE Trans. Med. Imag. 16, 166–175 (1997)

    Article  Google Scholar 

  4. Mumcuoglu, E.U., Leahy, R., Cherry, S.R.: Bayesian reconstruction of pet images: Methodology and performance analysis. Phys. Med. Biol. 41, 1777–1807 (1996)

    Article  Google Scholar 

  5. Ollinger, J.M.: Maximum-likelihood reconstruction of transmission images in emission computed tomography via the em algorithm. IEEE Trans. Med. Imag. 13, 89–101 (1994)

    Article  Google Scholar 

  6. TurkingtonT, G.: Introduction to pet instrumentation. J. Nucl. Med. Technol. 29, 4–11 (2001)

    Google Scholar 

  7. Bergstrom, M., Litton, J., Eriksson, L., Bohm, C., Blomqvist, G.: Determination of object contour from projections for attenuation correction in cranial positron emission tomography. J. Comput. Assist. Tomogr. 6, 365–372 (1982)

    Article  Google Scholar 

  8. Weinzapfel, B.T., HutchinsG, D.: Automated pet attenuation correction model for functional brain imaging. J. Nucl. Med. 42, 483–491 (2001)

    Google Scholar 

  9. Censor, Y., Gustafson, D., Lent, A., Tuy, H.: A new approach to the emission computerized tomography problem: simultaneous calculation of attenuation and activity coefficients. IEEE Trans. Nucl. Sci. 26, 2275–2279 (1979)

    Article  Google Scholar 

  10. Krol, A., Bowsher, J.E., Manglos, S.H., Feiglin, D.H., Tomai, M.P., Thomas, F.D.: An em algorithm for estimating spect emission and transmission parameters from emissions data only. IEEE Trans. Med. Imag. 20, 218–232 (2001)

    Article  Google Scholar 

  11. Nuyts, J., Dupont, P., Stroobants, S., Benninck, R., Mortelmans, L., Suetens, P.: Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms. IEEE Trans. Med. Imag. 18, 393–403 (1999)

    Article  Google Scholar 

  12. Dicken, V.: A new approach towards simultaneous activity and attenuation reconstruction in emission tomography. Inverse Probl. 15, 931–960 (1999)

    Article  MATH  MathSciNet  Google Scholar 

  13. Liu, H., Tian, Y., Shi, P.: PET image reconstruction: A robust state space approach. In: Christensen, G.E., Sonka, M. (eds.) IPMI 2005. LNCS, vol. 3565, pp. 197–209. Springer, Heidelberg (2005)

    Chapter  Google Scholar 

  14. Anscombe, F.J.: The transformation of poisson, binomial and negative-binomial data. Biometrika (1948)

    Google Scholar 

  15. Nrgaard, M., Poulsen, N., Ravn, O.: Advances in derivative-free state estimation for nonlinear systems. Technical report IMM-REP-1998-15 (2000)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2006 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Liu, H., Tian, Y., Shi, P. (2006). Simultaneous Estimation of PET Attenuation and Activity Images with Divided Difference Filters. In: Yang, GZ., Jiang, T., Shen, D., Gu, L., Yang, J. (eds) Medical Imaging and Augmented Reality. MIAR 2006. Lecture Notes in Computer Science, vol 4091. Springer, Berlin, Heidelberg. https://doi.org/10.1007/11812715_38

Download citation

  • DOI: https://doi.org/10.1007/11812715_38

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-37220-2

  • Online ISBN: 978-3-540-37221-9

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics