Skip to main content

A Light Intensity Measurement System for the Analytical Ultracentrifuge

  • Conference paper
  • First Online:
Analytical Ultracentrifugation VIII

Part of the book series: Progress in Colloid and Polymer Science ((PROGCOLLOID,volume 131))

Abstract

Light intensity measurements are required by absorbance, fluorescence, turbidity and low-angle light scattering detectors in order to determine the concentration distributions encountered in analytical ultracentrifugation. By using four fast analog-to-digital converters operating in parallel, a data acquisition system has been developed for the analytical ultracentrifuge that can acquire light intensity readings from three detectors (e.g. photomultipliers, avalanche photodiodes, etc.) simultaneously. For each detector, up to forty thousand intensity readings are acquired during each rotor revolution, for up to ten revolutions. Software synchronizes data acquisition with the spinning rotor. The use of continuous light sources allows simultaneous acquisition of dozens of intensity readings from all of the samples. Data acquisition is fast, allowing rapid radial scanning of samples. This data acquisition scheme is used in the Aviv Biomedical AU-FDS fluorescence detection retrofit system for the Beckman XLI analytical ultracentrifuge. It also will be used for the updated XLI absorbance system, as well as the next generation of analytical ultracentrifuge.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Laue TM, Yphantis DA, Rhodes DG (1984) Anal Biochem 143:103–112

    Article  CAS  Google Scholar 

  2. Laue TM, Domanik DM, Yphantis DA (1983) Anal Biochem 131:220–231

    Article  CAS  Google Scholar 

  3. Scholtan W, Lange H (1972) Polymere 250:782–796

    CAS  Google Scholar 

  4. Mächtle W (1999) Biophys J 76:1080–1091

    Google Scholar 

  5. Roark DE (2004) Biophys Chem 2004 108:121–126

    Article  CAS  Google Scholar 

  6. MacGregor IK, Anderson AL, Laue TM (2004) Biophys Chem 108:165–185

    Article  CAS  Google Scholar 

  7. Dam J, Schuck P (2004) Methods Enzymol 384:185–212

    CAS  Google Scholar 

Download references

Acknowledgments

The authors wish to thank the following individuals for their patient help and encouragement in making this system a reality: Rachel Kroe, Jack Correia, Edward Eisenstein, Jeff Hansen, Bo Demeler, Jack Aviv and Ash Tripathy. This research was supported in part by NIH grant R01GM6283601, NSF grant DBI-9876582, the Biomolecular Interactions Technology Center, the Center to Advance Molecular Interaction Technology and the Aviv Family Foundation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Thomas M. Laue .

Editor information

Christine Wandrey Helmut Cölfen

Rights and permissions

Reprints and permissions

About this paper

Cite this paper

Laue, T.M., Austin, J.B., Rau, D.A. A Light Intensity Measurement System for the Analytical Ultracentrifuge. In: Wandrey, C., Cölfen, H. (eds) Analytical Ultracentrifugation VIII. Progress in Colloid and Polymer Science, vol 131. Springer, Berlin, Heidelberg. https://doi.org/10.1007/2882_001

Download citation

Publish with us

Policies and ethics