Abstract
A mixture model clustering algorithm is presented for robust MRI brain image segmentation in the presence of partial volume averaging. The method uses additional classes to represent partial volume voxels of mixed tissue type in the data with their probability distributions modeled accordingly. The image model also allows for tissue-dependent variance values and voxel neighborhood information is taken into account in the clustering formulation. The final result is the estimated fractional amount of each tissue type present within a voxel in addition to the label assigned to the voxel. A multi-threaded implementation of the method is evaluated using both synthetic and real MRI data.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
H. S. Choi, D. R. Haynor, and Y. Kim, “Partial volume tissue classification of multichannel magnetic resonance images-a mixel model,” in IEEE Transactions on Medical Imaging, vol. 10, pp. 395–407, Sept. 1991.
L. Nocera and J. C. Gee, “Robust partial volume tissue classification of cerebral MRI scans,” in SPIE Medical Imaging (K. M. Hanson, ed.), vol. 3034, pp. 312–322, Feb. 1997.
D. H. Laidlaw, K. W. Flescher, and A. H. Barr, “Partial-volume Bayesian classification of material mixtures in MR volume data using voxel histograms,” in IEEE Transactions on Medical Imaging, vol. 17, pp. 74–86, Feb. 1998.
D. W. Shattuck, S. R. Sandor-Leahy, K. A. Schaper, D. A. Rottenberg, and R. M. Leahy, “Magnetic resonance image tissue classification using a partial voume model,” 2000. Submitted.
J. A. Hartigan, Clustering algorithms. New York: John Wiley & Sons, Inc., 1975.
R. O. Duda and P. E. Hart, Pattern classification and scene analysis. New York: John Wiley & Sons, Inc., 1973.
J. Ashburner and K. Friston, “Multimodal image coregistration and partitioning-a unified framework,” in Neuroimage, vol. 6, pp. 209–217, Oct. 1997.
S. M. Smith, “Robust automated brain extraction,” in Sixth Int. Conf. on Functional Mapping of the Human Brain, p. 625, 1998.
J. G. Sled, A. P. Zijdenbos, and A. C. Evans, “A nonparametric method for automatic correction of intensity nonuniformity in MRI data,” in IEEE Transactions on Medical Imaging, vol. 17, pp. 87–97, Feb. 1998.
R.-S. Kwan, A. Evans, and G. B. Pike, An Extensible MRI Simulator for Post-Processing Evaluation, vol. 1131 of Lecture Notes in Computer Science, pp. 135–140. Springer-Verlag, May 1996.
D. L. Collins, A. Zijdenbos, V. Kollokian, J. Sled, N. Kabani, C. Holmes, and A. Evans, “Design and construction of a realistic digital brain phantom,” in IEEE Transactions on Medical Imaging, vol. 17, pp. 463–468, June 1998.
J. C. Rajapakse and F. Kruggel, “Segmentation of MR images with intensity inhomogeneities,” in Image and Vision Computing, vol. 16, pp. 165–180, 1998.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2001 Springer-Verlag berlin Heidelberg
About this paper
Cite this paper
Noe, A., Gee, J.C. (2001). Partial Volume Segmentation of Cerebral MRI Scans with Mixture Model Clustering. In: Insana, M.F., Leahy, R.M. (eds) Information Processing in Medical Imaging. IPMI 2001. Lecture Notes in Computer Science, vol 2082. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-45729-1_44
Download citation
DOI: https://doi.org/10.1007/3-540-45729-1_44
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-42245-7
Online ISBN: 978-3-540-45729-9
eBook Packages: Springer Book Archive