Skip to main content

Possibilities and Limitations of the Transcutaneous Measuring Technique a Theoretical Analysis

  • Chapter
Continuous Transcutaneous Monitoring

Part of the book series: Advances in Experimental Medicine and Biology ((ABBI,volume 7))

Abstract

It is well known that oxygen and carbon dioxide can pass the human epidermis and that this transport occurs by diffusion1. Therefore, it is possible to measure noninvasively Po2 and PCO2 values on the skin surface. The first direct Po2 measurements on the skin surface by Evans and Naylor (1967)2, however, were disappointing because the Po2 value was very close to zero. First Pco2 measurements by Huch et al. (1967)3 revealed rather large Pco2 values. However, a short report of Baumberger and Goodfriend (1951)4, in which they demonstrated that the Po2 of a phosphate buffer heated up to 45°C and brought in contact with the skin of a finger approached arterial Po2, was a challenge to study the different parameters which influence skin surface Po2 and Pco2 in order to find out the kind of information which can be obtained from such noninvasive transcutaneous Po2 and Pco2 measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. R. Huch, A. Huch, and D.W. Lubbers, “Transcutaneous Po2,” Thieme-StrattonInc., New York, Georg Thieme Verlag, Stuttgart-New York (1981).

    Google Scholar 

  2. N.T.S. Evans, and P.F.D. Naylor, The systemic oxygen supply to thesurface of human skin, Respir. Physiol. 3:21–27 (1967).

    Article  Google Scholar 

  3. A. Huch, D.W. Lubbers, and R. Huch, Patientenüberwachung durch transcutanePco2-Messung bei gleichzeitiger Kontrolle der relativen lokalen Perfusion, Anaesthesist 22:379–380 (1973).

    Google Scholar 

  4. J.P. Baumberger, and R.B. Goodfriend, Determination of arterial oxygentension in man by equilibration through intact skin, Fed. Proc. 10: 10 (1951).

    Google Scholar 

  5. U. Grossmann, J. Huber, K. Fricke, and D.W. Lubbers, A new method forsimulating the oxygen pressure field of skin, in: “Oxygen Transport to Tissue”, Adv. Physiol. Sci., Vol. 25, A.G.B. Kovach, E. Dora, M. Kessler, I.A. Silver, eds., Pergamon Press, Akadémiai Kiadó, Budapest, pp. 319–320 (1980).

    Google Scholar 

  6. U. Grossmann, Simulation of combined transfer of oxygen and heatthrough the skin using a capillary loop model, Math. Biosci. 61: 205–236 (1982).

    Article  MATH  Google Scholar 

  7. P. Eberhard, Continuous oxygen monitoring of newborns by skin sensors,Dissertation, Basel (1976).

    Google Scholar 

  8. J.A. Quinn, Gas transfer through the skin: A two layer model relatingtranscutaneous flux to arterial tension, in: “Oxygen Transport to Tissue III”, I.A. Silver, M. Erecińska, H.I. Bicher, eds., Plenum Press, New York, pp. 175–181 (1978).

    Chapter  Google Scholar 

  9. Lubbers, D.W., Cutaneous and transcutaneous Po2 and Pco2 and theirmeasuring conditions, in: “Continuous Transcutaneous Blood Gas Monitoring”, A. Huch, R. Huch, J.F. Lucey, eds., Birth Defects, Original Article Series, Vol. XV, 4, The National Foundation March of Dimes, A.R. Liss, New York, pp. 13–31 (1979).

    Google Scholar 

  10. A.M. Thunstrom, M.J. Stafford, and J.W. Severinghaus, A two temperature,two Po2 method of estimating the determinations of tcPo2, in: “Continuous Transcutaneous Blood Gas Monitoring”, A. Huch, R. Huch, J.F. Lucey, eds., Birth Defects, Original Article Series, Vol. XV, 4, The National Foundation March of Dimes, A.R. Liss, New York, pp. 167–182 (1979).

    Google Scholar 

  11. T.J. Ryan, The blood vessels of the skin, in: “The Physiology andPathophysiology of the Skin”, A. Jarrett, ed., Academic Press, London, pp. 577–801 (1973).

    Google Scholar 

  12. D.W. Lubbers, Theoretical basis of the transcutaneous blood gas measurement,Crit.Care Med.: 9:721–733 (1981).

    Article  Google Scholar 

  13. D.W. Lubbers, and U. Grossmann, Gas exchange through the human epidermisas a basis of tcPo2 and tcPco2 measurements, in: “Continuous Transcutaneous Blood Gas Monitoring”, R. Huch, A. Huch, eds., M. Dekker, New York-Basel, pp. 1–34 (1983).

    Google Scholar 

  14. U. Grossmann, P. Winkler, and D.W. Lubbers, Coupled transport of O2and CO2 within the upper skin simulated by the capillary loop model, in: “Oxygen Transport to Tissue V”, Adv. Exp. Med. &Biol., Vol. 169, D.W. Lubbers, H. Acker, E. Leniger-Follert, T.K. Goldstick, eds., Plenum Press, New York-London, pp. 125–132 (1984).

    Google Scholar 

  15. R. Huch, A. Huch, and D.W. Lubbers, Transcutaneous measurement ofblood Po2 (tcPo2) - Method and application in perinatal medicine, J. Perinat. Med. 1:183–191 (1973).

    Article  Google Scholar 

  16. U. Grossmann, P. Winkler, and D.W. Lubbers, The effect of differentparameters (temperature, O2 consumption, blood flow, hemoglobin content) on the tcPo2 calibration curves calculated by the capillary loop model, in: “Oxygen Transport to Tissue VI”, Adv. Exp. Med. &Biol., Vol. 180, D. Bruley, H.I. Bicher, D. Reneau, eds., Plenum Press, New York-London, pp. 793–802 (1984).

    Google Scholar 

  17. R. Huch, A. Huch, K. Meinzer, and D.W. Lubbers, Eine schnelle beheiztePt-Oberflächenelektrode zur kontinuierlichen Überwachung des pO2 beim Menschen, Med. Tech., Stuttgart (1972).

    Google Scholar 

  18. C.R. Wyss, F.A. Matsen III, R.V. King, C.W. Simons, and E.M. Burgess,Dependence of transcutaneous oxygen tension on local pressure gradient in normal subjects, Clin. Sci. 60:499 (1981).

    Google Scholar 

  19. J.M. Steinacker, W. Spittelmeister, R.E. Wodick, F. Fallenstein, andD.W. Lubbers, Untersuchungen über die Blutflußabhängigkeit des transcutanen Sauerstoffpartialdruckes, Biomed. Tech. 30:92–93 (1985).

    Article  Google Scholar 

  20. U. Grossmann, and P. Winkler, Transients of gas exchange processes inthe upper skin calculated by the capillary loop model, in: “Oxygen Transport to Tissue VI”, Adv. Exp. Med. &Biol., Vol. 180, D. Bruley, H.I. Bicher, D. Reneau, eds., Plenum Press, New York-London, pp. 35–41 (1984).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1987 Plenum Press, New York

About this chapter

Cite this chapter

Lübbers, D.W. (1987). Possibilities and Limitations of the Transcutaneous Measuring Technique a Theoretical Analysis. In: Huch, A., Huch, R., Rooth, G. (eds) Continuous Transcutaneous Monitoring. Advances in Experimental Medicine and Biology, vol 7. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-1927-6_2

Download citation

  • DOI: https://doi.org/10.1007/978-1-4613-1927-6_2

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4612-9071-1

  • Online ISBN: 978-1-4613-1927-6

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics