Skip to main content

Ventricular Assistance and Replacement

  • Chapter
Congestive Heart Failure

Abstract

The standard methods for support of the failing heart have been discussed. The use of inotropic agents, after-load reduction, and intraaortic balloon counterpulsation are important techniques and can provide circulatory support in many patients. Occasionally, however, more aggressive measures are needed. This chapter outlines a brief historical background of ventricular assist device development, several types of pulsatile ventricular assist devices and total artificial hearts, nonpulsatile systems, some of the devices currently under development, the indications for mechanical ventricular assistance and management problems, and the bridge-to-transplantation and postoperative postcardiotomy cardiogenic shock clinical results.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Gibbon JH Jr. Application of a mechanical heart and lung apparatus to cardiac surgery. Minn Med. 1954;37:171–185.

    PubMed  Google Scholar 

  2. Stuckey JH, Newman MN, Dennis C. The use of heart-lung machine in selected cases of acute myocardial infarction. Surg Forum. 1957;8:342–344.

    PubMed  CAS  Google Scholar 

  3. Spencer FC, Eiseman B, Trinkle JK, Rossi NP. Assisted circulation for cardiac failure following intracardiac surgery with cardiopulmonary bypass. J Thorac Cardiovasc Surg. 1965;49:56–73.

    PubMed  CAS  Google Scholar 

  4. Akutsu T, Kolff WJ. Permanent substitutes for valves and hearts. Trans Am Soc Artif Intern Organs. 1958;4:230–235.

    Google Scholar 

  5. Cooley DA, Liotta ID, Hallman GL, Bloodwell RD, Leachman RD, Milam JB. Orthotopic cardiac prosthesis for two-staged cardiac replacement. Am J Cardiol. 1969;24:723–730.

    Article  PubMed  CAS  Google Scholar 

  6. Griffith BP, Hardesty RL, Kormos RL, et al. Temporary use of the Jarvik-7 total artificial heart before transplantation. N Engl J Med. 1987;316:130–134.

    Article  PubMed  CAS  Google Scholar 

  7. Quinn RD, Pae WE, Pierce WS. The Use of Mechanical Circulatory Assistance as a Bridge to Transplantation: The Penn State Experience. Springer-Verlag of Heidelberg, in press.

    Google Scholar 

  8. Pennock JL, Pierce WS, Campbell DB, et al. Mechanical support of the circulation followed by cardiac transplantation. J Thorac Cardiovasc Surg. 1986;96:994–1004.

    Google Scholar 

  9. Hill JD, Farrar DJ, Hershon JS, et al. Use of prosthetic ventricle as a bridge to cardiac transplantation for postinfarction cardiogenic shock. N Engl J Med. 1986;314:626–628.

    Article  PubMed  CAS  Google Scholar 

  10. Pierce WS, Parr GVS, Myers JL, Pae WE Jr, Bull AP, Waldhausen JA. Ventricular assist pumping in patients with cardiogenic shock after cardiac operations. N Engl J Med. 1981;305:1606–1610.

    Article  PubMed  CAS  Google Scholar 

  11. DeVries WC, Anderson JL, Joyce LD, et al. Clinical use of the total artificial heart. N Engl J Med. 1984;310:273–278.

    Article  PubMed  CAS  Google Scholar 

  12. DeVries WC. The permanent artificial heart: four case reports. JAMA. 1988;259:849–859.

    Article  PubMed  CAS  Google Scholar 

  13. Harken DE. Presented at the International College of Cardiology Meeting, Brussels, Belgium, 1958.

    Google Scholar 

  14. Kantrowitz A, Tjonneland S, Krakauer JS, Phillips SJ, Freed PS, Butner AN. Mechanical assistance in cardiogenic shock: hemodynamic effects. Arch Surg. 1968; 97:1000–1004.

    PubMed  CAS  Google Scholar 

  15. Powell WJ, Daggett WM, Magro AE, et al. Effects of intra-aortic balloon counterpulsation on cardiac performance, oxygen consumption and coronary blood flow in dogs. Circ Res. 1970;26:753–764.

    PubMed  Google Scholar 

  16. Buckley MJ, Leinbach RC, Kastor JA, et al. Hemodynamic evaluation of intra-aortic balloon pumping in man. Circulation. 1970;41(Suppl II):II-130–II-134.

    Google Scholar 

  17. Rose EA, Marrin CAS, Bregman D, Spotnitz HM. Left ventricular mechanics of counterpulsation and left heart bypass, individually and in combination. J Thorac Cardiovasc Surg. 1979;77:127–137.

    PubMed  CAS  Google Scholar 

  18. Baron DW, O’Rourke MD. Long-term results of arterial counterpulsation in acute severe cardiac failure complicating myocardial infarction. Br Heart J. 1976;38:285–288.

    Article  PubMed  CAS  Google Scholar 

  19. Talpins NL, Kripke DC, Goetz RH. Counterpulsation and intra-aortic balloon pumping in cardiogenic shock: circulatory dynamics. Arch Surg. 1968;97:991–1000.

    PubMed  CAS  Google Scholar 

  20. Bregman D, Casarella WJ. Percutaneous intra-aortic balloon pumping: initial clinical experiences. Ann Thorac Surg. 1980;29:153–155.

    Article  PubMed  CAS  Google Scholar 

  21. Subramanian VA, Goldstein JE, Sos TA, McCabe JC, Hoover EA, Gay WA. Preliminary clinical experience with percutaneous intra-aortic balloon pumping. Circulation. 1980;62(Suppl I):I123–I129.

    PubMed  CAS  Google Scholar 

  22. Richenbacher WE, Pierce WS. Management of complications of intra-aortic balloon counterpulsation. In: Waldhausen JA, Orringer MB, eds. Complications in Cardiothoracic Surgery. Chicago: Mosby Year Book; 1991:97–102.

    Google Scholar 

  23. Pae WE Jr, Pierce WS. Intra-aortic balloon counterpulsation, ventricular assist pumping and the artificial heart. In: Baue AE, ed. Glenn’s Thoracic and Cardiovascular Surgery. 5th ed. Norwalk, CT: Appleton & Lange; 1991:1585–1613.

    Google Scholar 

  24. Chachques JC, Grandjean PA, Pfeffer TA, et al. Cardiac assistance by atrial or ventricular cardiomyoplasty. J Heart Transplant. 1990;May/June 9(3):239–251.

    PubMed  Google Scholar 

  25. Chagas ACP, Moreira LFP, DaLuz PL, et al. Stimulated preconditioned skeletal muscle cardiomyoplasty, an effective means of cardiac assist. Circulation. 1989;80(Suppl 3)(3):202–208.

    Google Scholar 

  26. Pfeffer MA, Pfeffer JM. Ventricular enlargement and reduced survival after myocardial infarction. Circulation. 1987;75(Suppl4):93–97.

    Google Scholar 

  27. Fox RM, Nestico PF, Munley BJ, Hakki AH, Neuman D, Iskandvian AS. Coronary artery cardiomyopathy. Hemodynamic and prognostic implications. Chest. 1986; 89:352–356.

    Article  PubMed  CAS  Google Scholar 

  28. Magovern GJ, Park SB, Kao RL, Christlieb IY, Magovern GJ Jr. Dynamic cardiomyoplasty in patients. J Heart Transplant. 1990;May/June 3(1):258–263.

    Google Scholar 

  29. Magovern JA, Furnary A, Magovern GJ, Christlieb I, Kao RL. Preliminary results with cardiomyoplasty in the United States. In: Norman JC, ed. Cardiovascular Science and Technology: Basic and Applied II. Oxymoron Press; 1990:34–35.

    Google Scholar 

  30. Kantrowitz A, McKinnan WMP. The experimental use of the diaphragm as an axillary myocardium. Surg Forum. 1959;9:266.

    Google Scholar 

  31. Acker MA, Anderson WA, Hammond RL, et al. Skeletal muscle ventricles in circulation—one to eleven weeks’ experience. J Thorac Cardiovasc Surg. 1987;94(2):163–174.

    PubMed  CAS  Google Scholar 

  32. Hammond RL, Bridges CR, DiMeo F, Stephenson LW. Performance of skeletal muscle ventricles: effects of ventricular chamber size. J Heart Transpl. 1990;9:252–257.

    CAS  Google Scholar 

  33. Novoa R, Jacob G, Sakakibura N, et al. Muscle-powered circulatory assist device for diastolic counterpulsator. Trans Am Soc Artif Organs. 1989;XXXV:408–411.

    Google Scholar 

  34. Neilson IR, Chiu RC-J. Skeletal muscle-powered cardiac assist using an extra-aortic balloon pump. In: Chiu RC-J, ed. Biomechanical Cardiac Assist: Cardiomyoplasty and Muscle-Powered Devices. Mt. Kisco, NY: Futura Publishing Company; 1986:141–150.

    Google Scholar 

  35. Acker MA, Anderson WA, Hammond RL, et al. Skeletal muscle ventricles in circulation: short-term studies. J Thorac Cardiovasc Surg. 1987;94:163–164.

    PubMed  CAS  Google Scholar 

  36. Ott RA, Mills TC, Eugene J, Gazzumga AB. Clinical choices for circulatory assist devices. Trans Soc Artif Intern Organs. 1990;XXXVI:792–798.

    Google Scholar 

  37. Carpentier A, Perier P, Brugger JP, et al. Heterotopic artificial heart as a bridge-to-cardiac transplantation. Lancet. 1986;2:97–98.

    Article  PubMed  CAS  Google Scholar 

  38. Ganzel BL, Gray LA, Slater AD, Mavroudis C. Surgical techniques for the implantation of heterotopic prosthetic ventricles. Ann Thorac Surg. 1989;47:113–120.

    Article  PubMed  CAS  Google Scholar 

  39. Richenbacher WE, Pierce WS. Management of complications of mechanical circulatory assistance. In: Waldhausen JA, Orringer MB, eds. Complications in Cardiothoracic Surgery. Chicago: Mosby Year Book; 1991:103–113.

    Google Scholar 

  40. Portner PM, Oyer PE, Pennington G, et al. Implantable electric left ventricular assist system: bridge-to-transplantation and the future. Ann Thorac Surg. 1989; 47:142–150.

    Article  PubMed  CAS  Google Scholar 

  41. Frazier OH, Nakatani T, Duncan M, Parnis SM, Fuqua JM. Clinical experience with the Hemopump. Trans Am Soc Artif Intern Organs. 1989;XXXV:604–606.

    Google Scholar 

  42. Flameng W, Nees U, Sergeant P, Wellens F, Daenen W. Hemolytic complications during left ventricular assist using the hemopump. J Am Coll Cardiol. 1991; 17(2):3757A.

    Google Scholar 

  43. Rose DM, Laschinger J, Grossi E, Krieger KH, Cunningham JN Jr, Spencer FC. Experimental and clinical result with a simplified left heart assist device for treatment of profound left ventricular dysfunction. World J Surg. 1985;9:11–17.

    Article  PubMed  CAS  Google Scholar 

  44. Noon GP, Sekula ME, Glueck J, Coleman CL, Feldman L. Comparison of Delphin and Biomedicus pumps. Trans Am Soc Artif Intern Organs. 1990;36(3):616–619.

    Google Scholar 

  45. Pennington DG, Merjavy JP, Codd JE, Swartz MT, Miller LL, Williams GA. Extracorporeal membrane oxygenation for patients with cardiogenic shock. Circulation. 70(3, pt 2):I130–I137.

    Google Scholar 

  46. Phillip SJ, Zeft RH, Kongtahworn C, et al. Percutaneous cardiopulmonary bypass: application and indication for use. Ann Thorac Surg. 1989;47:121–123.

    Article  Google Scholar 

  47. Joyce LD, Kiser JC, Eales F, King RM, Toninato CJ, Hansen J. Experience with the Sarns centrifugal pump as a ventricular assist device. Trans Am Soc Artif Intern Organs. 1990;36(3):619–623.

    Google Scholar 

  48. Magovern GJ, Park SB, Maher TD. Use of a centrifugal pump without anticoagulants for postoperative left ventricular assist. World J Surg. 1985;925–936.

    Google Scholar 

  49. Park SB, Liebler GA, Burkholder JA, et al. Mechanical support of the failing heart. Ann Thorac Surg. 1986; 42:627–631.

    Article  PubMed  CAS  Google Scholar 

  50. Landis DL, Pierce WS, Rosenberg G, Donachy JH, Brighton JA. Long-term in-vivo automatic electronic control of the artificial hearts. Trans Am Soc Artif Intern Organs. 1977;23:519–525.

    PubMed  CAS  Google Scholar 

  51. Request for Proposal No. NHLBI-HV-86–02. Development of implantable cardiac biventricular assist and replacement devices. 1986;January.LI-6–7.

    Google Scholar 

  52. Rosenberg G, Snyder A, Landisu DL, Geselowitz DB, Donachy JH, Pierce WS. An electric motor-driven total artificial heart: seven months survival in the calf. Trans Am Soc Artif Intern Organs. 1984;30:69–74.

    PubMed  CAS  Google Scholar 

  53. Hill, JD. Bridging to cardiac transplantation. Ann Thorac Surg. 1989;47:167–171.

    Article  PubMed  CAS  Google Scholar 

  54. Pennington DG, McBridge LR, Swartz MT. Use of the Pierce-Donachy ventricular assist device in patients with cardiogenic shock after cardiac operations. Ann Thorac Surg. 1989;47:130–135.

    Article  PubMed  CAS  Google Scholar 

  55. Copeland JO, Emery RW, Levinson MM, et al. Selection of patients for cardiac transplantation. Circulation. 1987;75:1–9.

    Article  Google Scholar 

  56. Pierce WS. Clinical left ventricular bypass. Problems of pump inflow obstruction and right ventricular failure. ASAIO J. 1979;2:1–9.

    Google Scholar 

  57. Pantalos GM, Marks JD, Riebman JB, et al. Left ventricular oxygen consumption and organ blood flow distribution during pulsatile ventricular assist. Trans Am Soc Artif Intern Organs. 1988;34:356–360.

    CAS  Google Scholar 

  58. Davis PK, Pae WE, Miller CA, Parascandola SA. Reduction of myocardial oxygen consumption during left atrial to aortic bypass: are pulsatility and synchronization important? Surg Forum. 1989;210:206.

    Google Scholar 

  59. Copeland JB, Harlear LA, Joist JH, Devries WC. Panel 3: bleeding and anticoagulation. From Circulatory Support Symposium of the Society of Thoracic Surgeons, St. Louis, Missouri, February 6–7, 1988. Ann Thorac Surg. 1989;47:88–95.

    Article  Google Scholar 

  60. Pae WE Jr, Parascandola SA, Miller CA, Pierce WS. Results of mechanical circulatory support as a “bridge” to cardiac transplantation—combined Registry Report. In: Copper DKC, Novitzky D, eds. The Transplantation and Replacement of Thoracic Organs. Amsterdam: Kluwer Academic Publishers; 1990:445–452.

    Chapter  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1994 Springer-Verlag New York, Inc.

About this chapter

Cite this chapter

Quinn, R.D., Pierce, W.S., Pae, W.E. (1994). Ventricular Assistance and Replacement. In: Hosenpud, J.D., Greenberg, B.H. (eds) Congestive Heart Failure. Springer, New York, NY. https://doi.org/10.1007/978-1-4613-8315-4_29

Download citation

  • DOI: https://doi.org/10.1007/978-1-4613-8315-4_29

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4613-8317-8

  • Online ISBN: 978-1-4613-8315-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics