Abstract
Magnetic resonance angiography (MRA) has become an important technique in vascular diseases. Although conventional digital subtraction angiography (DSA) still is the gold standard for the evaluation of vascular pathology, MRA provides more than just anatomic information. In all MRA techniques, image contrast is the result of blood motion. Therefore, the influence of the hemodynamics of blood flow on the magnetic resonance (MR) signal intensity is obvious and measurable. MRA is noninvasive and safe. Whether a two-dimensional (2-D) or three-dimensional (3-D) sequence is used, a complete 3-D data set can be acquired within a few minutes. Data postprocessing allows for unlimited projections of vessels after the examination is concluded. As a result of recent technical improvements in image quality and vessel depiction, the spatial resolution now approaches that of DSA. Furthermore, particularly in young patients, the reduced use of x-rays is desirable. During the past few years, the administration of contrast agents and development of high-power gradient systems has contributed to major advances in spatial and temporal resolution and the imaged field of view. The popular 3-D contrast MRA uses small intravenous doses of paramagnetic contrast media for high-resolution arteriography, which results in a favorable signal-to-noise ratio (SNR) owing to enhanced longitudinal relaxation time (T1) shortening. This technique has been evaluated in an increasing number of diseases. Thus, arterial catheterization with its potential complications and nephrotoxicity due to iodinated contrast agents is being partially replaced by MRA.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References and Recommended Reading
Parker DL, Yuan C, Blatter DD: MR angiography by multiple thin slab 3D acquisition. Magn Resort Med 1991, 17:434–451.
NASCET Collaborators: Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med 1991, 325:445–453.
Anzola GP, Gasparotti R, Magoni M, Prandini F: Transcranial Doppler sonography and magnetic resonance angiography in the assessment of collateral hemispheric flow in patients with carotid artery disease. Stroke 1995, 26:214–217.
Patel MR, Kuntz KM, Klufas RA, et al.: Preoperative assessment of the carotid bifurcation. Can magnetic resonance angiography and duplex ultrasonography replace contrast arteriography? Stroke 1995, 26:1753–1758.
Baumgartner RW, Mattle HP, Aaslid R: Transcranial color-coded duplex sonography, magnetic resonance angiography, and computed tomography angiography; Methods, applications, advantages, and limitations. J Clin Ultrasound 1995, 23:89–111.
Benjamin MS, Gillams AR, Carter AP: Carotid MRA: what advantages do the turbo field-echo and 3D phase-contrast sequences offer? Neuroradiology 1997, 39:469–473.
Bradley WG: Recent advances in magnetic resonance angiography of the brain. Curr Opin Neurol Neurosurg 1992, 5:859–862.
Carpenter JP, Holland GA, Golden MA, et al.: Magnetic resonance angiography of the aortic arch. J Vasc Surg 1997, 25:145–151.
Cloft HJ, Murphy KJ, Prince MR, Brunberg JA: 3D gadolinium-enhanced MR angiography of the carotid arteries. Magn Reson Imaging 1996, 14:593–600.
Heid O, Remonda L: Gd-enhanced 3D MRA of the carotid arteries. Int Soc Magn Reson Med 1998, 1:556.
Baumgartner RW, Baumgartner I, Mattle HP, Schroth G: Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis. AJNR Am J Neuroradiol 1997, 18:127–133.
Lee LJ, Kidwell CS, Alger J, et al. Impact on stroke subtype diagnosis of early diffusion-weighted magnetic resonance imaging and magnetic resonance angiography. Stroke 2000, 31:1081–1089.
Mattle HP, Edelman RR: Cerebral magnetic resonance angiography. Neurol Res 1992, 14:118–121.
Patrux B, Laissy JP, Jouini S, et al.: Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects. Neuroradiology 1994, 36:193–197.
Bernasconi A, Bogousslavsky J, Bassetti C, Regli F: Multiple acute infarcts in the posterior circulation. J Neurol Neurosurg Psychiatry 1996, 60:289–296.
Jacobs A, Lanfermann H, Neveling M, et al.: MRI-and MRA-guided therapy of carotid and vertebral artery dissections. J Neurol Sci 1997, 147:27–34.
Auer A, Felber S, Schmidauer C, et al.: Magnetic resonance angiographie and clinical features of extracranial vertebral artery dissection. J Neurol Neurosurg Psychiatry 1998, 64:474–481.
Ruggieri PM, Masaryk TJ, et al.: Intracranial magnetic resonance imaging. Invest Radiol 1992, 27(suppl 2):S33–S39.
Christophe C, Azzi N, Bouche B, et al.: Magnetic resonance imaging and angiography in cerebral fungal vasculitis. Neuropediatrics 1999, 30:218–220.
Mattle HP, Wentz KU, Edelman RR, et al.: Cerebral venography with MR. Radiology 1991, 178:453–458.
Essig M, Engenhart R, Knopp MV, et al.: Cerebral arteriovenös malformations: improved nidus demarcation by means of dynamic tagging MR-angiography. Magn Reson Imaging 1996, 14:227–233.
Essig M, Reichenbach JR, Schad LR, et al.: High-resolution MR venography of cerebral arteriovenous malformations. Magn Reson Imaging 1999, 17:1417–1425.
Ostertun B, Solymosi L: Magnetic resonance angiography of cerebral developmental venous anomalies: its role in differential diagnosis. Neuroradiology 1993, 35:97–104.
Crecco M, Floris R, Vidiri A, et al.: Venous angiomas: plain and contrast-enhanced MRI and MR angiography. Neuroradiology 1995, 37:20–24.
Ross JS, Masaryk TJ, Modic MT, et al.: Intracranial aneurysms: evaluation by MR angiography. AJNR Am J Neuroradiol 1990, 11:449–455.
Shigematsu Y, Korogi Y, Hirai T, et al.: 3D TOF turbo MR angiography for intracranial arteries: phantom and clinical studies. J Magn Reson Imaging 1999, 10:939–944.
Korogi Y, Takahashi M, Mabuchi N, et al.: Intracranial aneurysms: diagnostic accuracy of three-dimensional, Fouriertransform, time-of-flight angiography. Radiology 1994, 193:181–186.
Huston J III, Nichols DA, Luetmer PH, et al.: Blinded prospective evaluation of sensitivity of MR angiography to known intracranial aneurysms: importance of aneurysm size. AJNR Am J Neuroradiol 1994, 15:1607–1614.
Huston J III, Rufenacht DA, Ehmann RL, Wiebers DO: Intracranial aneurysms and vascular malformations: comparison of time-of-flight and phase-contrast MR angiography. Radiology 1991, 181:721–730.
Huston JD, Ehman RL: Comparison of time-of-flight and phase-contrast MR neuroangiographic techniques. Radiographies 1993, 13:5–19.
Isoda H, Ramsay RG, Takehara Y, et al.: MR angiography of aneurysm models of various shapes and neck sizes. AJNR Am J Neuroradiol 1997, 18:1463–1472.
Lang EW, Steffens JC, Link J, Mehdorn HM. The utility of contrast-enhanced MR-angiography for posterior fossa giant cerebral aneurysm management. Neurol Res 1998, 20:705–708.
Wardlaw JM, White PM: The detection and management of unruptured intracranial aneurysms. Brain 2000, 123:205–221.
Wilms G, Guffens M, Gryspeerdt S, et al.: Spiral CT of intracranial aneurysms: correlation with digital subtraction and magnetic resonance angiography. Neuroradiology 1996, 38(suppl l):S20–S25.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2001 Current Medicine, Inc.
About this chapter
Cite this chapter
Weber, J., Forsting, M. (2001). Magnetic Resonance Angiography. In: Fisher, M., Bogousslavsky, J. (eds) Current Review of Cerebrovascular Disease. Current Medicine Group, London. https://doi.org/10.1007/978-1-4684-0001-4_8
Download citation
DOI: https://doi.org/10.1007/978-1-4684-0001-4_8
Publisher Name: Current Medicine Group, London
Print ISBN: 978-1-4684-0003-8
Online ISBN: 978-1-4684-0001-4
eBook Packages: Springer Book Archive