Midterm Follow-Up of the Bioimplant™ (Liotta) Heart Valve

  • Chapter
Indications for Heart Valve Replacement by Age Group
  • 44 Accesses

Abstract

The use of a low profile bioprosthesis is interesting in particular anatomical conditions. In some patients with mitral stenosis, the left ventricular cavity is not enlarged. The characteristic low profile of this valve avoids obstruction of flow and traumatization of the left ventricular wall. In the tricuspid position, this design is particularly interesting because it leaves the right ventricular cavity totally free. From February 1981 to November 1984, 280 St. fude Medical, Inc. BIOIMPLANT™ (Liotta) low profile bioprostheses were implanted in 251 patients in our hospital. Eighty-six patients underwent aortic valve replacement (AVR). Preoperatively, 64% of patients were in New York Heart Association (NYHA) Classes HI and IV. One hundred thirty-eight patients had mitral valve replacement (MVR), and II had tricuspid valve replacement (TVR). Twenty-two patients underwent mitral and aortic valve replacement (DVR). The operative mortality was 8.2% (AVR 5.8%, MVR 10%, DVR 9%). The 236 operative survivors were followed over a period of 3 months to 4 years. Actuarial analysis of late results indicates an expected survival rate at 4 years of 92.2 ± 2.7% for the whole group (AVR 96%, MVR 89.2%, DVR 94.6%). The actuarial rate of patients free of thromboembolism was 98.1 ± 1% (MVR 98.7%, DVR 86.8%); 96.1 ± 2.1% of patients were predicted to be free of infection at 4 years (AVR 97.2%, MVR 94.8%). The actuarial rate of freedom from valve failure was 89.6% (AVR 83.3%, MVR 96%). Postoperatively, 91.2% of patients were in NYHA Classes I or II.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1989 Kluwer Academic Publishers

About this chapter

Cite this chapter

Gandjbakhch, I., Bors, V., Fontanel, M., Pavie, A., Cabrol, C., Cabrol, A. (1989). Midterm Follow-Up of the Bioimplant™ (Liotta) Heart Valve. In: Gomez-Duran, C., Reul, G.J. (eds) Indications for Heart Valve Replacement by Age Group. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-6900-4_10

Download citation

  • DOI: https://doi.org/10.1007/978-1-4684-6900-4_10

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4684-6902-8

  • Online ISBN: 978-1-4684-6900-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics