Skip to main content

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 219.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 279.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 279.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Notes

  1. 1.

    1 Dacron catheters have an intermediate sheath in which interwoven Dacron fibers are employed. Considerable stiffness, reduced deformation index (curve memory) as well as a good torsional ratio (transmission from the body to the tip of the torsion carried out by operator's hand) characterize this material. At body temperature this material tends to soften (bioflexibility) within 20–30 min, making it less traumatic when it must be placed for a long time inside cardiac structures such as, for instance, the coronary sinus. Polyurethane catheters have a steel net which enables good axial (suitability to transmit axial strength along the catheter axis) and torsional control. Furthermore, these catheters are rather flexible, and their distal segments lack a metal reinforcement making the tip more flexible and reducing the risk of causing trauma with the catheter. Since polyurethane catheters have high thermal endurance, they do not tend to soften and their maneuvrability characteristics tend to remain constant. In general polyurethane catheters cost much less than dacron catheters.

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag London Limited

About this chapter

Cite this chapter

Casella, M., Russo, A.D. (2008). The Electrophysiologic Study. In: An Atlas of Radioscopic Catheter Placement for the Electrophysiologist. Springer, London. https://doi.org/10.1007/978-1-84800-227-2_3

Download citation

  • DOI: https://doi.org/10.1007/978-1-84800-227-2_3

  • Publisher Name: Springer, London

  • Print ISBN: 978-1-84800-226-5

  • Online ISBN: 978-1-84800-227-2

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics