Abstract

Mechanical circulatory support (MCS) became next after heart transplantation clinically recognized way of treatment for patients suffered from end-stage heart failure. Nowadays, long term MCS is realized mostly by means of implantable rotary blood pumps (RBP). Clinically utilized MCS systems have limited capabilities of pump operation supervision and patient’s monitoring. A few of them were equipped with remote data transmission to external data base. In this paper the telemonitoring system intended for Polish rotary cardiac assist system ReligaHeart ROT has been presented. The necessity of remote monitoring of supported patient as well as pump operation has been justified by referring to clinical cases of commercial MCS system HVAD (Medtronic) application.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Warrell, D., Cox, T., Firth, J., Dwight, J.: Oxford Textbook of Medicine: Cardiovascular Disorders, pp. 215–218. Oxford University Press, Oxford (2016)

    Google Scholar 

  2. Schroder, J.N., Milano, C.A.: A tale of two centrifugal left ventricular assist devices. J. Thorac. Cardiovasc. Surg. 154, 850–852 (2017)

    Article  Google Scholar 

  3. Antończyk, R., Trejnowska, E., Pacholewicz, J., et al.: Emergency heartware ventricular assist device (HVAD) exchange due to pump thrombosis using minimally invasive technique. Kardiochir. Torakochi. 14(1), 76–78 (2017)

    Google Scholar 

  4. Kirklin, J.K., Pagani, F.D., Kormos, R.L., et al.: Eighth annual INTERMACS report: special focus on framing the impact of adverse events. J. Heart Lunt Transplant. 36(10), 1080–1086 (2017)

    Article  Google Scholar 

  5. Kaufman, F., Hörmandinger, C., et al.: Acoustic spectral analysis for determining pump thrombosis in rotary blood pumps. ASAIO J. 60(5), 502–507 (2014)

    Article  Google Scholar 

  6. Bennett, M.K., Adatya, S.: Blood pressure management in mechanical circulatory support. J. Thorac. Dis. 7(12), 2125–2128 (2015)

    Google Scholar 

  7. Marko, C., Danzinger, G., Käferbäck, M., et al.: Safety and efficacy of cardiac rehabilitation for patients with continuous flow left ventricular assist devices. Eur. J. Prev. Cardiol. 22(11), 1378–1384 (2015)

    Article  Google Scholar 

  8. Major, R., Kustosz, R., Trembecka-Wójciga, K., et al.: Development of surface modification methods for ReligaHeart cardiac support system. Arch. Metall. Mater. 61(3), 1053–1058 (2016)

    Google Scholar 

  9. Gawlikowski, M., Kustosz, R., Glowacki, M., et al.: Non-invasive assessment of thromboembolism in rotary blood pumps: case study. In: Proceedings of SPIE, 12th Conference on Integrated Optics: Sensors, Sensing Structures, and Methods, vol. 10455, p. 104550L (2017)

    Google Scholar 

  10. Csepe, T., Kilic, A.: Advancements in mechanical circulatory support for patients in acute and chronic heart failure. J. Thorac. Dis. 9(10), 4070–4083 (2017)

    Article  Google Scholar 

  11. Schlöglhofer, T., Horvat, J., Hartner, Z., et al.: Standardized telephone intervention algorithm for improved ventricular assist device outpatient management. J. Heart Lunt Transplant. 35(4), S388 (2014)

    Article  Google Scholar 

  12. Granegger, M., Masetti, M., Laohasurayodhin, R., et al.: Continuous monitoring of aortic valve opening in rotary blood pump patients. IEEE Trans. Bio-Med. Eng. 63(6), 1201–1207 (2016)

    Article  Google Scholar 

  13. Granegger, M., Schlöglhofer, T., Ober, H., et al.: Daily life activity in patients with left ventricular assist devices. Int. J. Artif. Organs 39(1), 22–27 (2016)

    Article  Google Scholar 

  14. Rich, J.D., Burkhoff, D.: HVAD flow waveform morphologies: theoretical foundation and implications for clinical practice. ASAIO J. 63(5), 526–535 (2017)

    Article  Google Scholar 

Download references

Acknowledgements

This work has been financially supported by National Centre of Research and Development (grant no. RH-ROT/266798/STRATEGMED–II).

Following commercial companies were involved in telemonitoring project: WASKO S.A., Gliwice, Poland; Pro-PLUS S.A., Warsaw, Poland.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Maciej Gawlikowski .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Gawlikowski, M. et al. (2019). Necessity of Telemonitoring in Patients Treated by Means of Cardiac Assist Systems on the Example of Polish Rotary Blood Pump ReligaHeart ROT. In: Tkacz, E., Gzik, M., Paszenda, Z., Piętka, E. (eds) Innovations in Biomedical Engineering. IBE 2018. Advances in Intelligent Systems and Computing, vol 925. Springer, Cham. https://doi.org/10.1007/978-3-030-15472-1_10

Download citation

Publish with us

Policies and ethics