Accurate Calculation of Heart Period and Pulse Wave Transit Time

  • Conference paper
  • First Online:
XV Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 (MEDICON 2019)

Part of the book series: IFMBE Proceedings ((IFMBE,volume 76))

Abstract

The first step in processing of physiological signals is usually the improvement of the signal-to-noise ratio. However, the applicable filtering methods not only suppress noise but also distort the signal. As a result, parameters derived from filtered physiological signals are also distorted. The paper evaluates filtering methods applied to electrocardiographic (ECG) and photoplethysmographic (PPG) signals in the process of calculating heart period (HP) and pulse wave transit time (PWTT). Band-pass filtering applied in the course of QRS detection causes a shift in R-peak location depending on the QRS waveform. Following QRS detection accurate R-peak localization is suggested using re-filtering of the original signal. The HP was calculated as the time interval between two adjacent R-peaks and also as the time interval between two adjacent local minima in PPG (PPGmin). Both real and simulated data were used for the evaluation. In the latter case the fiducial points of the signals (ECG R-peak and PPGmin locations) were exactly known providing reference positions for the evaluation of filter distortion. Inappropriate filtering shifts the fiducial points. This causes a significant error while calculating parameters by subtraction, like RR interval of heart cycles (tRR, difference of two consecutive R-peak locations) or PWTT (difference of PPGmin and the associated R-peak location). Even more accurate R-peak and PPGmin localization is needed when variation in tRR and PWTT is analyzed. These variations characterize the actual stress level of a person before or during blood pressure measurement more accurately than average heart rate displayed by commercially available blood pressure monitors. Based on accurate R-peak and PPGmin localization it has been confirmed that for the same heart cycle the time interval is different between two R-peaks and two PPGmins.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Sörnmo, L., Laguna, P.: Electrocardiogram (ECG) Signal Processing. Wiley Encyclopedia of Biomedical Engineering. Wiley, Hoboken (2006)

    Book  Google Scholar 

  2. Floran, J.S.: Blood pressure variability: a novel and important risk factor. Can. J. Cardiol. 29(5), 557–563 (2013)

    Article  Google Scholar 

  3. Bernston, G.G., Bigger Jr., J.T., Eckberg, D.L., Grossman, P., Kaufmann, P.G., et al.: Committee report: heart rate variability: origins, methods and interpretive caveats. Psychophysiol. J. 34(6), 623–648 (1997)

    Article  Google Scholar 

  4. Jobbágy, Á., Csordás, P., Mersich, A.: Blood pressure measurement at home. In: Proceedings of World Congress on Medical Physics and Biomedical Engineering 2006, pp. 3453–3456. Springer, Heidelberg (2007)

    Google Scholar 

  5. Csordás, P., Mersich, A., Jobbágy, Á.: Advanced indirect method for measuring blood pressure. Period. Polytech. Electr. Eng. 53(3–4), 115–121 (2011)

    Google Scholar 

  6. Friesen, G.M., Jannett, T.C., Jadallah, M.A., Yates, S.L., Quint, S.R., Nagle, H.T.: A comparison of the noise sensitivity of nine QRS detection algorithms. IEEE Trans. Biomed. Eng. 37(1), 85–98 (1990)

    Article  Google Scholar 

  7. Thakor, N.V., Webster, J.G., Tompkins, W.J.: Estimation of QRS complex power spectra for design of a QRS filter. IEEE Trans. Biomed. Eng. 11, 702–706 (1984)

    Article  Google Scholar 

  8. Kohler, B.-U., Hennig, C., Orglmeister, R.: The principles of software QRS detection. IEEE Eng. Med. Biol. Mag. 21(1), 42–57 (2002)

    Article  Google Scholar 

  9. Pan, J., Tompkins, W.J.: A real-time QRS detection algorithm. IEEE Trans. Biomed. Eng. 32(3), 230–236 (1985)

    Article  Google Scholar 

  10. Elgendi, M., Jonkman, M., DeBoer, F.: Heart rate variability and the acceleration plethysmogram signals measured at rest. In: International Joint Conference on Biomedical Engineering Systems and Technologies, pp. 266–277. Springer, Heidelberg (2010)

    Chapter  Google Scholar 

Download references

Acknowledgement

The research has been supported by the European Union, co-financed by the European Social Fund (EFOP-3.6.2-16-2017-00013).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Péter Nagy .

Editor information

Editors and Affiliations

Ethics declarations

The authors declare that they have no conflict of interest.

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Nagy, P., Jobbágy, Á. (2020). Accurate Calculation of Heart Period and Pulse Wave Transit Time. In: Henriques, J., Neves, N., de Carvalho, P. (eds) XV Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019. MEDICON 2019. IFMBE Proceedings, vol 76. Springer, Cham. https://doi.org/10.1007/978-3-030-31635-8_32

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-31635-8_32

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-31634-1

  • Online ISBN: 978-3-030-31635-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics