Abstract

The accuracy of images obtained by Diffuse Optical Tomography (DOT) could be substantially increased by the newly developed time resolved (TR) cameras. These devices result in unprecedented data volumes, which present a challenge to conventional image reconstruction techniques. In addition, many clinical applications require taking photons in air regions like the trachea into account, where the diffusion model fails. Image reconstruction techniques based on photon tracking are mandatory in those cases but have not been implemented so far due to computing demands. We aimed at designing an inversion algorithm which could be implemented on commercial graphics processing units (GPUs) by making use of information obtained with other imaging modalities. The method requires a segmented volume and an approximately uniform value for the reduced scattering coefficient in the volume under study. The complex photon path is reduced to a small number of partial path lengths within each segment resulting in drastically reduced memory usage and computation time. Our approach takes advantage of wavelength normalized data which renders it robust against instrumental biases and skin irregularities which is critical for realistic clinical applications. The accuracy of this method has been assessed with both simulated and experimental inhomogeneous phantoms showing good agreement with target values. The simulation study analyzed a phantom containing a tumor next to an air region. For the experimental test, a segmented cuboid phantom was illuminated by a supercontinuum laser and data were gathered by a state of the art TR camera. Reconstructions were obtained on a GPU-installed computer in less than 2 h. To our knowledge, it is the first time Monte Carlo methods have been successfully used for DOT based on TR cameras. This opens the door to applications such as accurate measurements of oxygenation in neck tumors where the presence of air regions is a problem for conventional approaches.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 199.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 199.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Zhu C, Liu Q (2013) Review of Monte Carlo modeling of light transport in tissues. J Biomed Opt 18(5):050902

    Article  Google Scholar 

  2. Andreas HH, Raymond EA, Randall LB (1998) Comparison of finite-difference transport and diffusion calculations for photon migration in homogeneous and heterogeneous tissues. Phys Med Biol 43(5):1285

    Article  Google Scholar 

  3. Fang Q, Boas DA (2009) Monte Carlo simulation of photon migration in 3D turbid media accelerated by graphics processing units. Opt Express 17(22):20178–20190

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  4. Alerstam E, Andersson-Engels S, Svensson T (2008) White Monte Carlo for time-resolved photon migration. J Biomed Opt 13(4):041304. -041304-10

    Article  PubMed  Google Scholar 

  5. Liu Q, Ramanujam N (2007) Scaling method for fast Monte Carlo simulation of diffuse reflectance spectra from multilayered turbid media. J Opt Soc Am A 24(4):1011–1025

    Article  Google Scholar 

  6. Niclass C et al (2008) A 128×128 single-photon image sensor with column-level 10-bit time-to-digital converter array. IEEE J Solid State Circuits 43(12):2977–2989

    Article  Google Scholar 

Download references

Acknowledgments

This work was supported by the SwissTransMed project ONIRIUS, Swiss Cancer Research project KFS-3732-08-2015, KFSP Tumor Oxygenation and KFSP Molecular Imaging Network Zurich of the University of Zurich, and by the National Competence Center for Biomedical Imaging.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Salvador Sanchez Majos .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Springer International Publishing AG

About this chapter

Cite this chapter

Jiang, J., Ahnen, L., Kalyanov, A., Lindner, S., Wolf, M., Majos, S.S. (2017). A New Method Based on Graphics Processing Units for Fast Near-Infrared Optical Tomography. In: Halpern, H., LaManna, J., Harrison, D., Epel, B. (eds) Oxygen Transport to Tissue XXXIX. Advances in Experimental Medicine and Biology, vol 977. Springer, Cham. https://doi.org/10.1007/978-3-319-55231-6_26

Download citation

Publish with us

Policies and ethics