Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 22))

Abstract

Microneedle array electrodes for EEG significantly reduce the mounting time, particularly by circumvention of the need for skin preparation by scrubbing. We designed a new replication process for numerous types of microneedle arrays. Here, polymer microneedle array electrodes with 64 microneedles, in a nested 4×4 array, positioned on a circular disk of 10 mm diameter were fabricated and characterized. Needles have a length of 320 μm with a diameter of 100 μm. The DC-resistance of Ag-coated microneedle array electrodes on the skin is of the order of 150 kΩ. Using electrolyte gel this value decreases at least by a factor of 10. The pilot measurements on a healthy volunteer show excellent signal-to-noise ratios. According to conventional electrodes also Ag/AgCl instead of Ag only was used to coat the microneedle array. Both coatings, either with or without gel, certified for EEG recordings.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 429.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 549.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Griss, P., Enoksson, P., Tolvanen-Laakso, H., Merilainen, P., Ollmar, S., Stemme, G. Micromachined electrodes for biopotential measurements. Journal of Microelectromechanical Systems, 2001, 10, 10–16.

    Article  Google Scholar 

  2. Griss, P., Tolvanen-Laakso, H. K., Merilainen, P., Stemme, G. Characterization of micromachined spiked biopotential electrodes. IEEE Trans Biomed Eng, Jun 2002, 49(6), 597–604.

    Article  Google Scholar 

  3. Matteucci, M., Carabalona, R., and E. Di Fabricio, M. C., Gramatica, F., Rienzo, M. D., Snidero, E., Gavioli, L., Sancrotti, M. Micropatterned dry electrodes for brain-computer interface. Microelectronic Engineering, 2007, 84, 1737–1740.

    Article  Google Scholar 

  4. Luttge, R., Berenschot, E., de Boer MJ et al., M. Integrated lithographic molding for microneedle-based devices. Journal of Microelectromechanical Systems, 2007, 16(4), 872–884.

    Article  Google Scholar 

  5. Bystrova, S., Luttge, R., van den Berg., A. Study of crack formation in high-aspect ratio SU-8 structures on silicon. Microelectronic Engineering, 2007, 84(5–8), 1113–1116.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Regina Luttge .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Luttge, R., Bystrova, S.N., van Putten, M.J.A.M. (2009). Microneedle array electrode for human EEG recording. In: Vander Sloten, J., Verdonck, P., Nyssen, M., Haueisen, J. (eds) 4th European Conference of the International Federation for Medical and Biological Engineering. IFMBE Proceedings, vol 22. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-89208-3_297

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-89208-3_297

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-89207-6

  • Online ISBN: 978-3-540-89208-3

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics