Skip to main content

Noise Reduction in Low-Dose Cone Beam CT by Incorporating Prior Volumetric Image Information

  • Conference paper
World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China

Part of the book series: IFMBE Proceedings ((IFMBE,volume 39))

  • 151 Accesses

Abstract

Repeated use of cone beam CT (CBCT) in radiotherapy introduces extra imaging dose to patients. In this work, we propose a method to effectively reduce the imaging dose of on-treatment CBCT by incorporating previously acquired CBCT. The Karhunen-Loève (KL) transform was used to consider the correlation among the on-treatment low dose CBCT and prior CBCTs in the projection domain. Following the KL transform, the selected CBCT projection data were decomposed into un-correlated, ordered principle components. Then, a penalized weighted least-squares (PWLS) criterion was applied to restore each KL component using different penalty strengths, where the penalty parameter was inversely proportional to its corresponding KL eigenvalue. Following the inverse KL transform on the processed data, the FDK algorithm was used to reconstruct the on-treatment CBCT image. The proposed algorithm was evaluated using both a CatPhan 600 phantom and an anthropomorphic head phantom. The proposed algorithm demonstrated the ability to suppress noise while preserving edge information effectively. This new strategy outperforms the PWLS algorithm without considering prior information based on the noise-resolution tradeoff measurement and analyze of the reconstructed small objects. Information extracted from previously acquired CBCT can be effectively utilized to suppress noise in on-treatment low-dose CBCT. The presented strategy can significantly lower the patient CBCT radiation dose without compromising the quality of the images.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Ouyang, L., Solberg, T., Wang, J. (2013). Noise Reduction in Low-Dose Cone Beam CT by Incorporating Prior Volumetric Image Information. In: Long, M. (eds) World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China. IFMBE Proceedings, vol 39. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-29305-4_479

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-29305-4_479

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-29304-7

  • Online ISBN: 978-3-642-29305-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics