Development and Deployment of a Microfluidic Platform for Water Quality Monitoring

  • Chapter
Smart Sensors for Real-Time Water Quality Monitoring

Part of the book series: Smart Sensors, Measurement and Instrumentation ((SSMI,volume 4))

Abstract

There is an increasing demand for autonomous sensor devices which can provide reliable data on key water quality parameters at a higher temporal and geographical resolution than is achievable using current approaches to sampling and monitoring. Microfluidic technology, in combination with rapid and on-going developments in the area of wireless communications, has significant potential to address this demand due to a number of advantageous features which allow the development of compact, low-cost and low-powered analytical devices. Here we report on the development of a microfluidic platform for water quality monitoring. This system has been successfully applied to in-situ monitoring of phosphate in environmental and wastewater monitoring applications. We describe a number of the technical and practical issues encountered and addressed during these deployments and summarise the current status of the technology.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Directive 2000/60/EC of the European Parliament and of the Council of 23 October 2000, establishing a framework for Community action in the field of water policy

    Google Scholar 

  2. Council Directive 91/271/EEC of 21 May 1991, concerning urban waste water collection and treatment

    Google Scholar 

  3. Council Directive 91/676/EEC of 12 December 1991 concerning the protection of waters against pollution by nitrates from agricultural sources

    Google Scholar 

  4. Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption

    Google Scholar 

  5. Directive 2006/118/EC of the European Parliament and of the Council of 12 December 2006 on the protection of groundwater against pollution and deterioration

    Google Scholar 

  6. Moore, T.S., et al.: Marine chemical technology and sensors for marine waters: potentials and limits. Annual Review of Marine Science 1, 91–115 (2009)

    Article  Google Scholar 

  7. Dzakpasu, M., et al.: Nitrogen removal in an integrated constructed wetland treating domestic wastewater. Environ. Sci. Health. A. Tox. Hazard. Subst. Environ. Eng. 46, 742–750 (2011)

    Article  Google Scholar 

  8. Manz, A., et al.: Miniaturised total chemical analysis systems, a novel concept for chemical sensing. Sensors and Actuators B: Chemical B1, 244–248 (1990)

    Article  Google Scholar 

  9. Niessner, R.: Measuring the invisible. Analytical Chemistry 82, 7863–7863 (2010)

    Article  Google Scholar 

  10. Allan, I.J., et al.: A toolbox for biological and chemical monitoring requirements for the European Union’s Water Framework Directive. Talanta 69, 302–322 (2006)

    Article  Google Scholar 

  11. Diamond, D., et al.: Integration of analytical measurements and wireless communications - current issues and future strategies. Talanta 75, 606–612 (2008)

    Article  Google Scholar 

  12. Gardolinski, P.C.F.C., et al.: Miniature flow injection analyser for laboratory, shipboard and in situ monitoring of nitrate in estuarine and coastal waters. Talanta 58, 1015–1027 (2002)

    Article  Google Scholar 

  13. Doku, G.N., Haswell, S.J.: Further studies into the development of a micro-FIA (mu FIA) system based on electroosmotic flow for the determination of phosphate as orthophosphate. Anal. Chim. Acta 382, 1–10 (1999)

    Article  Google Scholar 

  14. Greenway, G.M., et al.: Characterisation of a micro-total analytical system for the determination of nitrite with spectrophotometric detection. Anal. Chim. Acta 387, 1–10 (1999)

    Article  Google Scholar 

  15. Petsul, P.H., et al.: The development of an on-chip micro-flow injection analysis of nitrate with a cadmium reductor. Anal. Chim. Acta 428, 155–161 (2001)

    Article  Google Scholar 

  16. Daridon, A., et al.: Chemical Sensing using an Integrated uFluidic System based on Colorimetrics: A Comparative Kinetic Study of the Bertholet Reaction for Ammonia Determination in Microfluidic and Spectrophotometric Systems. Sens. Actuators B 76, 235–243 (2001)

    Article  Google Scholar 

  17. Azzaro, F., Galletta, M.: Automatic colorimetric analyzer prototype for high frequency measurement of nutrients in seawater. Marine Chemistry 99, 191–198 (2006)

    Article  Google Scholar 

  18. Moscetta, P., Thompson, I.: The new in-situ chemical probes and the water quality monitoring platform. Environmental Risk Management Tools for Water Quality Monitoring, Southampton (UK) (March 30, 2009)

    Google Scholar 

  19. Alliance for Coastal Technologies, Performance Demonstration Statement for the American Ecotech NUT 1000 (2008), http://www.act-us.info/Download/Evaluations/Nutrient//AmerEco/

  20. Alliance for Coastal Technologies, Performance Demonstration Statement for the WET Labs Cycle-P Nutrient Analyzer (2008), http://www.act-us.info/Download/Evaluations/Nutrient/WETLabs/

  21. Alliance for Coastal Technologies, Performance Demonstration Statement for the YSI 9600 Nitrate Monitor (2007), http://www.act-us.info/Download/Evaluations/Nutrient/YSI/

  22. Vuillemin, R., et al.: CHEMINI: A new in situ chemical miniaturized analyzer. Deep Sea Research Part I: Oceanographic Research Papers 56, 1391–1399 (2009)

    Article  Google Scholar 

  23. Patey, M.D., et al.: Determination of nitrate and phosphate in seawater at nanomolar concentrations. Trends in Analytical Chemistry 27, 169–182 (2008)

    Article  Google Scholar 

  24. Sieben, V.J., et al.: Microfluidic colorimetric chemical analysis system: application to nitrite detection. Analytical Methods 2, 484–491 (2010)

    Article  Google Scholar 

  25. Bey, A.K., et al.: A high-resolution analyser for the measurement of ammonium in oligotrophic seawater. Ocean Dynamics 61, 1555–1565 (2011)

    Article  Google Scholar 

  26. Floquet, C.F.A., et al.: Nanomolar detection with high sensitivity microfluidic absorption cells manufactured in tinted PMMA for chemical analysis. Talanta 84, 235–239 (2011)

    Article  MathSciNet  Google Scholar 

  27. Beaton, A.D., et al.: Lab-on-chip measurement of nitrate and nitrite for in situ analysis of natural waters. Environmental Science & Technology 46, 9548–9556 (2012)

    Article  Google Scholar 

  28. Sequeira, M., Diamond, D.: Progress in the realisation of an autonomous environmental monitoring device for ammonia. Trends Anal. Chem. 21, 816–827 (2002)

    Article  Google Scholar 

  29. Bowden, M., et al.: Analysis of river water samples utilising a prototype industrial sensing system for phosphorus based on micro-system technology. J. Environ. Monit. 4, 767–771 (2002)

    Article  Google Scholar 

  30. Bowden, M., et al.: A prototype industrial sensing system for phosphorus based on micro system technology. Analyst 127, 1–4 (2002)

    Article  Google Scholar 

  31. Slater, C., et al.: Autonomous field-deployable device for the measurement of phosphate in natural water. In: Proc. SPIE 6755, Advanced Environmental, Chemical, and Biological Sensing Technologies V, vol. 67550L, pp. 67550L1–67550L8 (2007)

    Google Scholar 

  32. Slater, C., et al.: Validation of a fully autonomous phosphate analyser based on a microfluidic lab-on-a-chip. Water Sci. Technol. 61, 1811–1818 (2010)

    Article  Google Scholar 

  33. Environmental Protection Agency, Ireland, Water Quality in Ireland, 2001-2003 (2005), http://www.epa.ie/downloads/pubs/water/waterqua/epa_water_quality_2001-3.pdf

  34. Neal, C., et al.: Phosphate measurement in natural waters: two examples of analytical problems associated with silica interference using phosphomolybdic acid methodologies. Sci. Total Environ. 251/252, 511–522 (2000)

    Article  Google Scholar 

  35. Hach Company, DR/890 Datalogging Colorimeter Handbook, pp. 523–528 (1999)

    Google Scholar 

  36. Sullivan, T., Regan, F.: Biomimetic design for the development of novel sustainable antifouling methods for ocean monitoring technology. J. Ocean Technol. 6, 41–54 (2011)

    Google Scholar 

  37. Delauney, L., et al.: Biofouling protection for marine environmental sensors. Ocean Sci. 6, 503–511 (2010)

    Article  Google Scholar 

  38. PALL Corporation, Polyethersulfone Membrane (Hydrophilic), http://www.pall.com/main/OEM-Materials-and-Devices/Product.page?id=3949

  39. Jordan, P., et al.: High-resolution phosphorus transfers at the catchment scale: the hidden importance of non-storm transfers. Hydrol. Earth Syst. Sci. 9, 685–691 (2005)

    Article  Google Scholar 

  40. Jordan, P., et al.: Characterising phosphorus transfers in rural catchments using a continuous bank-side analyser. Hydrol. Earth Syst. Sci. 11, 372–381 (2007)

    Article  Google Scholar 

  41. Chapman, J., et al.: Phthalate doped PVC membranes for the inhibition of fouling. J. Membr. Sci. 365, 180–187 (2010)

    Article  Google Scholar 

  42. Chapman, J., et al.: Period four metal nanoparticles on the inhibition of biofouling. Colloids and Surfaces B: Biointerfaces 78, 208–216 (2010)

    Article  Google Scholar 

  43. Chapman, J.: The development of novel antifouling materials: A multi-disciplinary approach. PhD thesis, Dublin City University (2011)

    Google Scholar 

  44. Sullivan, T.: Investigation of biomimetic and engineered surface textures for biofouling reduction and prevention on environmental sensing platforms. PhD thesis, Dublin City University (2012)

    Google Scholar 

  45. Cleary, J., et al.: Analysis of phosphate in wastewater using an autonomous microfluidics-based analyser. World Academy of Science, Engineering and Technology 28, 196–199 (2009)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. Cleary .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Cleary, J., Maher, D., Diamond, D. (2013). Development and Deployment of a Microfluidic Platform for Water Quality Monitoring. In: Mukhopadhyay, S., Mason, A. (eds) Smart Sensors for Real-Time Water Quality Monitoring. Smart Sensors, Measurement and Instrumentation, vol 4. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-37006-9_6

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-37006-9_6

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-37005-2

  • Online ISBN: 978-3-642-37006-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics